Alkaline Phosphatase chromogen (BCIP/NBT) - Ready to Use (ab7468)

Overview

  • Product nameAlkaline Phosphatase chromogen (BCIP/NBT) - Ready to UseSee all Alkaline Phosphatase Chromogen reagents ...
  • Tested applicationsWB, Dot Blot, IHC-P, IHC-Fr more details
  • General notesBCIP: 5-bromo-4-chloro-3-indolyl phosphate NBT: p-nitroblue tetrazolium chloride This product used to be called "Alkaline phosphatase detection kit (BCIP/NBT)". Abcam has a wide range of primary and secondary antibodies available on the Abcam website to suit your protocol needs.
  • Properties

  • Storage instructionsStore at +4°C.
  • Storage bufferpH: 9.80
    Constituents: BCIP, NBT
  • Concentration information loading...
  • Research Areas
  • Applications

    Our Abpromise guarantee covers the use of ab7468 in the following tested applications.

    The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

    Application Notes
    WB WB: Use at an assay dependent concentration.

    BCIP/NBT system is based on hydrolysis of BCIP and reduction of NBT producing a deep purple reaction product. Reaction is several times more sensitive than existing products with little or no background staining. The reaction product is extremely stable and does not fade when exposed to light.
    Dot Blot Dot: Use at an assay dependent concentration.
    IHC-P IHC-P: Use at an assay dependent concentration.
    IHC-Fr IHC-Fr: Use at an assay dependent concentration.

    References for Alkaline Phosphatase chromogen (BCIP/NBT) - Ready to Use (ab7468)

    ab7468 has not yet been referenced specifically in any publications.

    Product Wall

    Displaying 1 - 10 of 19 results for Abreviews and Q&A

    Thank you for contacting us. Because we carry over 100,000 products, it isn't feasible for us to keep small sample sizes of our products. We only have the 100mL size available for ab7468.

    We are happy to reassure our customers that all of our p...

    Read More

    Thank you for your enquiry.

    I am sorry to confirm that ab133406 is not suitable for detection of AP. This detection system has been designed for optimal detection of HRP, and will not be as sensitive for detection of AP.

    I am sorry I...

    Read More

    Thank you for your inquiry. I am happy to confirm that all these products are suitable for WB and tested and guaranteed.
    I suggest ab29889 (Liver (Human) Tissue Lysate - adult normal tissue) as positive control for ab3366, ab3373, ab3375 and ab24102....

    Read More

    Thank you for your inquiry.

    I can confirm that the ab7468 Alkaline Phosphatase chromogen (BCIP/NBT)substrate is ready to use:

    Wash the membrane after incubation with the alkaline phosphatase secondary.
    Apply sufficient substrate...

    Read More

    Thank you for your reply.

    I looked over the protocol that you sent and it looks to be OK with me. I had a colleague look at it aswell and they thought it was good too.

    If there is anything else I can help you with, or if you have any f...

    Read More

    Thank you for calling Abcam earlier today.

    To be able to send a quote for the products you requested, please could you send me your shipping and billing address.

    Once I get this information, I can send that quote out.

    Also fo...

    Read More

    Thank you for contacting us.

    NBT/BCIP system produces a colorimetric substrate that yields an intense and insoluble black-purple precipitate when reaction with alkaline phosphatase.

    Unlike HRP chemiluminiscent methods, the chromogenic ...

    Read More

    I am not aware of any cross reactivity of this antibody with human Ig. However we do offer a number of secondary antibodies which are designed to reduce background levels by either being pre-absorbed against other proteins and Igs or by digestion into F(a...

    Read More

    Thank you for contacting me again. It is always a pleasure to hear from you.

    After reviewing your email, I am lead to believe that this really is a hook effect as you had mentioned. I am not an expert on this hook effect in plasma specifically,...

    Read More

    Thank you for contacting us, I am glad to hear that the new product is working well for you.

    Usually when color is developing slowly it is one of three issues. 1) the plates and reagents have not come to room temperature. 2) the conjugates are ...

    Read More
    