You have changed your country from  to  . Please be aware that this will change the currency in the purchasing process.

CETP Activity Assay Kit (Fluorometric) (ab65383)

Overview

  • Product nameCETP Activity Assay Kit (Fluorometric)See all Cholesteryl ester transfer protein kits ...
  • Tests
    1 x 100 assay
  • Sample type
    Cell culture supernatant, Urine, Serum, Plasma, Other biological fluids, Tissue Extracts
  • Assay typeQuantitative
  • Assay time
    1h 00m
  • Species reactivity
    Reacts with: all Mammals
  • Product overview

    Abcam's CETP Activity Assay Kit (Fluorometric) uses a donor molecule containing a fluorescent self-quenched neutral lipid that is transferred to an acceptor molecule in the presence of CETP. CETP-mediated transfer of the fluorescent neutral lipid to the acceptor molecule results in an increase in fluorescence (Excitation: 465 nm; Emission: 535 nm).
    Visit our FAQs page for tips and troubleshooting.

  • Tested applicationsFunctional Studies more details

Properties

  • RelevanceCholesteryl ester transfer protein is a member of the lipid transfer/lipopolysaccharide binding protein gene family. Cholesteryl ester transfer protein transfers neutral lipids from high-density lipoprotein (HDL) to very low-density lipoprotein (VLDL) and is present in normal human plasma and serum.
  • Cellular localizationSecreted, extracellular space.
    • Alternative names
        CETPHDLCQ10Lipid transfer proteinLipid transfer protein I

    Applications

    Our Abpromise guarantee covers the use of ab65383 in the following tested applications.

    The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

    Application Notes
    Functional Studies FuncS

    CETP Activity Assay Kit (Fluorometric) images

    • Cholesteryl Ester Transfer Protein Activity Assay with Rabbit.

    Protocols

    References for CETP Activity Assay Kit (Fluorometric) (ab65383)

    ab65383 has not yet been referenced specifically in any publications.

    Product Wall

    Displaying 1 - 10 of 12 results for Abreviews and Q&A



    Sorry for the confusion. This kit should be stored at 4 degrees C.


    The laboratory responded that frozen serum samples should be fine to use - as long as they have not undergone multiple freeze-thaw cycles. Additionally, the note of diluting the sample to 500uL with 1x CETP assay buffer is only applicable if a fluoro...

    Read More

    Thank you for your reply and for kindly providing these details.

    It has taken some time to discuss this with the originator of the kit, I appreciate your patience.

    Reviewing the details, I suggest to consider the following:
    Read More

    Thank you for taking the time tocontact us and provide these details. I am sorry to hear you have had difficulty obtaining satisfactory results from this kit.

    The details you have kindly provided will enable us to investigate this case for you ...

    Read More

    Thank you for contacting us and for your interest in Abcam products.

    1) Yes, please use black plates for all fluorometric assays.
    2) Yes, you should make a master mix with all components except the samples and distribute it across the wells b...

    Read More

    Thank you for your enquiry.

    Yes, as long as the samples are frozen appropriately and properly and have not been freeze thawed multiple times, they can be used with ab65383 CETP Activity Assay Kit. Both serum and plasma will make compatible samp...

    Read More

    Thank you for contacting us.

    We have not tried this kit with 2-3 year frozen stored samples however it is most likely to work. In the following publication http://atvb.ahajournals.org/content/15/1/112.full (Fig 2A) the author have observed a litt...

    Read More

    Thank you for your inquiry.

    I am happy to confirm that ab65383 can be used for cell extracts.

    Please use the assay buffer to prepare the cell extracts.

    I hope this information is helpful and wish you good luck with your resea...

    Read More

    Thank you for your inquiry.

    This kit works with mammalian plasma samples, soyes it will work with hamster.

    I hope this information helps. Please contact us with any other questions.

    Vielen Dank für Ihren Anruf.
    Ich habe Rücksprache mit den Fachleuten gehalten und kann Ihnen nun folgendes bestätigen.
    Wenn Ihre Filter (20nM breit) für beide Richtungen sind (+/-), dann können Sie einfach das Kit vermessen ohne Einbußen.
    F...

    Read More
    

    Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"