You have changed your country from  to  . Please be aware that this will change the currency in the purchasing process.

EasyLink FITC Conjugation Kit (1 x 1mg FITC) (ab102883)

Overview

  • Product nameEasyLink FITC Conjugation Kit (1 x 1mg FITC)See all FITC kits ...
  • Product overview

    EasyLink FITC Conjugation Kit provides a simple and quick process to conjugate your primary antibodies with FITC. FITC is a green fluorescent dye which has an excitation wavelength of 495nm and an emission wavelength of 519nm.

    The conjugated antibody can be used straight away in WB, ELISA, IHC etc

    Learn more about buffer compatibility, protein/secondary antibody conjugation and labelling chemistry in our FAQs.

    This kit is sufficient for 1 labeling reaction of 1-2mg of antibody.

  • Notes

    Pre-conugation considerations

    The purified antibody to be labeled should ideally be in 10-50mM amine-free buffer (e.g. MES, MOPS, HEPES, PBS), pH range 6.5 to 8.5. If the buffer is more concentrated or outside this pH range contact the technical support team.

    Common non-buffering salts (e.g. sodium chloride), chelating agents (e.g. EDTA), and sugars have no effect on conjugation efficiency. Azide (0.02 to 0.1%) and BSA (0.1 to 0.5%) have little or no effect. Glycerol up to 50% has no effect.

    Avoid buffer components that are nucleophilic, as these may react with EasyLink chemicals. Primary amines (e.g. amino acids or ethanolamine) and thiols (e.g. mercaptoethanol or DTT) fall within this class (Note: Tris-based buffers should be avoided). If your buffer contains primary amines and/or thiols, you should consider using our Concentration and Purification Kits (ab102778 or ab102784).

    Recommended amount and volume of antibody for optimal results

    Pack sizeAmount of antibodyVolume of antibody
    Up to 20 µg10-20 µg4-10 µl
    Up to 200 µg100-200 µg40-100 µl
    Up to 2 mg1-2 mg400-1000 µl

    Antibody concentrations of 1-4 mg/ml generally give optimal results. For conditions outside the suggested ranges contact the technical support team.

    Conjugation reaction

    1. Before adding the antibody to the EasyLink mix, add 1 µl of EL-Modifier reagent to each 10 µl of antibody to be labelled. Mix gently.
    2. Remove cap from vial of EasyLink mix and pipette the antibody sample (with added EL-Modifier) directly onto the lyophilized material. Resuspend gently by withdrawing and re-dispensing the liquid once or twice using a pipette.
    3. Replace cap on the vial and leave standing in the dark at room temperature (20-25°C) for 3 hours. Conjugations can also be set up and left overnight; longer incubation times have no negative effect on the conjugate.
    4. After incubating for 3 hours (or more), add 1 µl of EL-Quencher FD reagent for every 10 µl of antibody used and mix gently. The conjugate can be used after 30 minutes. The conjugates do not require purification.

    5. Storage of conjugates

      Storage at 4°C is recommended for any conjugate. A preservative may be desirable for long-term storage. Other storage conditions may also be satisfactory. The best conditions for any particular conjugate must be determined by experimentation.

      Disclaimer

      Labeling of the antibody will not work if the conjugation blocks the active paratope. This situation is rare.

    6. Tested applicationsConjugation more details

Properties

  • Alternative names
      FluoresceinFluorescein isothiocyanate

Applications

Our Abpromise guarantee covers the use of ab102883 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Notes
Conjugation Conjugation

EasyLink FITC Conjugation Kit (1 x 1mg FITC) images

  • This illustration demonstrates a general procedure and will slightly vary dependent on the conjugate used.

References for EasyLink FITC Conjugation Kit (1 x 1mg FITC) (ab102883)

ab102883 has not yet been referenced specifically in any publications.

Product Wall

Displaying 1 - 8 of 8 results for Abreviews and Q&A

Thank you for your enquiry and interest in our products.

It seems that 70mg is very high for an antibody concentration and I would check with the customer first whether they genuinely have 70mg of purified antibody or if they have 70mg of total ...

Read More

The optimal concentration of antibodies for conjugationwith our EasyLink FITC Conjugation kits is at least1mg/ml.You don't specify the antibody concentration; could use 0.5 mg/ml of antibody, but should be aware of a slightly impaired resulting conjugate....

Read More

Thank you for your inquiry.

Please see my answer to your customer's questions below:

1.) I can confirm that ab102883 is the correct size to label 1 mg of antibody.

2.) I can re-assure your customer that provided the protocols...

Read More

Thank you for contacting us.

I am looking into adding a sheep isotype control FITC conjugate to our catalogue. I will have an answer regarding avaiaibility tomorrow.

Currently, what we do have is unconjugated IgG (ab37385) and a conj...

Read More

Thank you for contacting us.

We currently do not have any publication information regarding its use in sheep BMSCs. I am sorry we can't offer any tested data. This antibody however was tested with sheep lysates and gave good staining so it is m...

Read More

Thank you for contacting us. Unfortunately, I would not recommend using a chicken antibody against a different target (such as ab1394 or ab63504), as it cannot be guaranteed that they do not react with any human antigen. I would rather suggest to use a ch...

Read More

Thank you for your email and interest in Abcam products. We currently do not have AlexaFluor conjugated antibodies or proteins available in our catalog. Having said this though, we have a number of products available that are conjugated to DyLight® flu...

Read More

Thank you for your enquiry. I can confirm that the antibody concentration should not cause an issue. The Easylink conjugation kits should still work with this lower concentration, although it will be it at a slightly reduced efficiency. I can reco...

Read More

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"