You have changed your country from  to  . Please be aware that this will change the currency in the purchasing process.

EasyLink Glucose Oxidase Conjugation Kit (1 x 1mg GOx) (ab102886)

Overview

  • Product nameEasyLink Glucose Oxidase Conjugation Kit (1 x 1mg GOx)See all GOx kits ...
  • Product overview

    EasyLink GOx Conjugation Kit provides a simple and quick process to conjugate your primary antibodies with GOx.

    The conjugated antibody can be used straight away in WB, ELISA, IHC etc

    Learn more about buffer compatibility, protein/secondary antibody conjugation and labelling chemistry in our FAQs.

    This kit is sufficient for 1 labeling reaction of 1mg of antibody.

  • Notes

    Amount and volume of antibody

    The best ratio for any new antibody reagent must be determined by experimentation but 80-100µg of IgG antibody for every 100µg of EL-GOx usually gives optimal results. The 100µg quantity of antibody corresponds to an Antibody:GOx molar ratio of 1:1 (Mw of GOx is 160kDa).

    The volume in which the antibody is added ideally should be between 400 and 1000µl.

    Protocol

    1. Before you add antibody to the EL-GOx mix, add 100µl of EL-Modifier reagent for 1ml of antibody to be labeled. Mix gently.
    2. Remove the screw cap from the vial of EL-GOx mix and pipette the antibody sample (with added EL-Modifier) directly onto the lyophilised material. Resuspend gently by withdrawing and re-dispensing the liquid once or twice using a pipette.
    3. Place the cap back on the vial and leave the vial standing for 3 hours in the dark at room temperature (20-25°C). Alternatively, and often more conveniently, conjugations can be set up and left overnight, as the longer incubation time has no negative effect on the conjugate.
    4. After incubating for 3 hours (or more), add 1µl of EL-Quencher reagent for every 10µl of antibody used. The conjugate can be used after 30 minutes.

    Storage of conjugates

    For any new conjugate, initial storage at 4°C is recommended. A preservative may be desirable for long-term storage. Other storage conditions (e.g. frozen at -70°C or stored at -20°C with 50% glycerol) may also be satisfactory. The best conditions for any particular conjugate must be determined by experimentation.

    Sample Buffer

    Ideally, the antibody to be labeled should be in 10-50mM amine-free buffer pH range 6.5 to 8.5. However, many buffers outside these limits of concentration and pH can be accommodated. Modest concentrations of Tris buffer are also tolerated.

    Amine-free buffers, including MES, MOPS, HEPES and phosphate are compatible if they are in the concentration range 10-50mM and have pH values in the range 6.5-8.5, as the addition of EL-Modifier provides the conditions necessary for efficient conjugation. Common non-buffering salts (e.g. sodium chloride), chelating agents (e.g. EDTA), and sugars may be present, as they have no effect on conjugation efficiency. Azide (0.02-0.1%) has little or no effect. If the amine-free buffer is relatively concentrated and outside the pH range 6.6-8.5 you may need to add more EL-modifier for each 10µl of antibody. Excess EL-Modifier is provided so that you can check the pH of the buffer after the addition of the modifier. Ideally the pH should be around 7.3-7.6, though efficient conjugation occurs anywhere between pH 6.8 and 7.8. Avoid buffer components that are nucleophilic, as these may react with EasyLink chemicals. If your buffer contains primary amines (e.g. amino acids, ethanolamine) and/or thiols (e.g. mercaptoethanol, DTT), you should consider using our Concentration and Purification Kits (ab102776 or ab102783). (Note: Unusually, for an amine, Tris has little effect on conjugation efficiency as long as the concentration is 20mM or less).

    Disclaimer

    Labeling of the antibody will not work if the conjugation blocks the active paratope. This situation is rare.

  • Tested applicationsConjugation more details

Properties

  • Alternative names
      Glucose oxidase

Applications

Our Abpromise guarantee covers the use of ab102886 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Notes
Conjugation Conjugation

EasyLink Glucose Oxidase Conjugation Kit (1 x 1mg GOx) images

  • This illustration demonstrates a general procedure and will slightly vary dependent on the conjugate used.

References for EasyLink Glucose Oxidase Conjugation Kit (1 x 1mg GOx) (ab102886)

ab102886 has not yet been referenced specifically in any publications.

Product Wall

There are currently no Abreviews or Questions for ab102886.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"