Read our guarantee »Anti-HP1 gamma antibody
See all HP1 gamma products (11) ...
Mouse monoclonal to HP1 gamma
WB, ICC/IF, IHC-Pmore details
Reacts with
Human
Recombinant full length protein, corresponding to amino acids 1-184 of Human HP1 gamma
Liquid
Shipped at 4°C. Upon delivery aliquot and store at -20°C or -80°C. Avoid repeated freeze / thaw cycles.
Preservative: None
PBS, pH 7.2
Concentration information loading...
Protein G purified
Monoclonal
IgG2a
kappa
Our Abpromise guarantee covers the use of ab56978 in the following tested applications.
The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.
WB: Use a concentration of 1 - 5 µg/ml.Predicted molecular weight: 21 kDa.
ICC/IF: Use a concentration of 10 µg/ml
IHC-P: Use a concentration of 1 µg/mlPerform heat mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol.
Seems to be involved in transcriptional silencing in heterochromatin-like complexes. Recognizes and binds histone H3 tails methylated at 'Lys-9', leading to epigenetic repression. May contribute to the association of the heterochromatin with the inner nuclear membrane through its interaction with lamin B receptor (LBR). Involved in the formation of functional kinetochore through interaction with MIS12 complex proteins.
Contains 2 chromo domains.
Phosphorylated by PIM1. Phosphorylated during interphase and possibly hyper-phosphorylated during mitosis.
Nucleus. Associates with euchromatin and is largely excluded from constitutive heterochromatin. May be associated with microtubules and mitotic poles during mitosis.
Target information above from: UniProt accessionQ13185
The UniProt Consortium
The Universal Protein Resource (UniProt) in 2010
Nucleic Acids Res. 38:D142-D148 (2010).
Immunofluorescence - HP1 gamma antibody (ab56978)

HP1 gamma antibody (ab56978) used in immunofluorescence at 10ug/ml on HeLa cells.
Western blot - HP1 gamma antibody (ab56978)

HP1 gamma antibody (ab56978) at 1ug/lane + HeLa cell lysate at 25ug/lane.
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections)-HP1 gamma antibody(ab56978)

IHC image of ab56978 staining in human colon formalin fixed paraffin embedded tissue section, performed on a Leica BondTM system using the standard protocol F. The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH6, epitope retrieval solution 1) for 20 mins. The section was then incubated with ab56978, 1µg/ml, for 15 mins at room temperature and detected using an HRP conjugated compact polymer system. DAB was used as the chromogen. The section was then counterstained with haematoxylin and mounted with DPX.
For other IHC staining systems (automated and non-automated) customers should optimize variable parameters such as antigen retrieval conditions, primary antibody concentration and antibody incubation times.
This product has been referenced in:
See 1 publication for this product
Publishing research using ab56978? Please let us know so that we can cite the reference in this datasheet
Concentration of lot no. is
Concentration not available for this lot.
Find concentration of your lot:

HP1 gamma antibody (ab56978) used in immunofluorescence at 10ug/ml on HeLa cells.

HP1 gamma antibody (ab56978) at 1ug/lane + HeLa cell lysate at 25ug/lane.

IHC image of ab56978 staining in human colon formalin fixed paraffin embedded tissue section, performed on a Leica BondTM system using the standard protocol F. The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH6, epitope retrieval solution 1) for 20 mins. The section was then incubated with ab56978, 1µg/ml, for 15 mins at room temperature and detected using an HRP conjugated compact polymer system. DAB was used as the chromogen. The section was then counterstained with haematoxylin and mounted with DPX.
For other IHC staining systems (automated and non-automated) customers should optimize variable parameters such as antigen retrieval conditions, primary antibody concentration and antibody incubation times.
1
Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"