| | | | Western blot - Angiotensin Converting Enzyme 2 antibody - Carboxy catalytic domain (ab38941)  (enlarge) | |
| |
| Product Name | Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
| | See all Angiotensin Converting Enzyme 2 antibodies (10)... |
| Product type | Primary antibodies |
| Description | Rabbit polyclonal to Angiotensin Converting Enzyme 2 - Carboxyterminal end catalytic domain |
| Immunogen | Synthetic peptide corresponding to the carboxy end of the catalytic domain of Human Angiotensin Converting Enzyme 2, between the zinc binding site and the sheddase cleavage site.
(Peptide available as ab41283.) |
| Reacts with | Hu |
| Predicted to react (species key) | Ms (Due to sequence homology) |
| Specificity | ab38941 recognises the Carboxy end of Catalytic domain of Angiotensin Converting Enzyme 2. We have a range of domain specific antibodies for this target. For a full list please see all Angiotensin Converting Enzyme 2 antibodies |
| Tested applications (see key) | WB |
|
| Abreviews | |
|
| Application notes (see key) | Recommended dilutions WB: A recommended starting concentration for Western blots is 1:1000 when using colorimetric substrates such as BCIP/NBT, and 1:5000 for chemiluminescent substrates. Higher concentrations of antibody may be needed for samples from more distantly related species. The full-length sequence for ACE-2 encodes an 805 amino acid protein with predicted mass of 92kDa. However,glycosylation and other post-translational modifications make the apparent molecular weight on SDS PAGE gels larger, about 120 kDa by Western blot. Many smaller forms may be seen on Western blot of culture media and biological fluid. Dilution optimised using Chromogenic detection. Not yet tested in other applications. Optimal dilutions/concentrations should be determined by the end user. |
| Cellular localization | Cell membrane; single pass type I membrane protein and secreted (processed form). |
| Research areas | Cardiovascular >> Vasculature >> Vasoconstriction >> Other Cardiovascular >> Heart >> Contractility >> Inotropics Cardiovascular >> Blood >> Blood Pressure regulation Cell Biology >> Proteolysis / Ubiquitin >> Proteolytic enzymes >> Metalloprotease >> ACEs |
| Relevance | Angiotensin converting enzyme 2 (ACE2) plays a central role in vascular, renal, and myocardial physiology. In contrast to its homolog ACE, ACE2 expression is restricted to heart, kidney, and testis. Recently ACE2 has also been shown to be a functional receptor of the SARS coronavirus. The normal function of ACE2 is to convert the inactive vasoconstrictor angiotensin I (AngI) to Ang1-9 and the active form AngII to Ang1 7, unlike ACE, which converts AngI to AngII. While the role of these vasoactive peptides is not well understood, lack of ACE2 expression in ace2-/ace2- mice leads to severely reduced cardiac contractility, indicating its importance in regulating heart function. ACE1 inhibitors such as catopril and lisinopril do not block ACE2 activity. ACE2 is restricted to the testis, heart, kidney and colon. The full length sequence for ACE2 encodes an 805 amino acid protein with predicted mass of 92.46 kDa and a pI of 5.22. |
| | Alternative names for Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain (ab38941) |
| Database links | The links below go to external sites and will open in a new browser window |
| Raised in | Rabbit |
| Clonality | Polyclonal |
| Isotype | IgG |
| Purity | Immunogen affinity purified |
| Storage buffer | Preservative: 0.05% Sodium Azide Constituents: 50% Glycerol Material safety datasheets (MSDS) for this product: Glycerol MSDS Sodium Azide MSDS
|
| Form | Liquid |
| Concentration | 1.000 mg/ml |
| Storage instructions | Shipped at 4°C. Upon delivery aliquot and store at -20°C. Avoid freeze / thaw cycles. |
| |
At Abcam, we have one centralized database to hold all of our product information, so that everything we know about this Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain is on this datasheet. But please do contact us if you would like any reassurance! |
 |
|
| See below for Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain images, references, products related to ab38941 and other tools. |
| |
Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain images: |
Western blot - Angiotensin Converting Enzyme 2 antibody - Carboxy catalytic domain (ab38941) All lanes : Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain (ab38941) at 1/1000 dilution
Lane 1 : ACE2 at 0.05 µg Lane 2 : ACE2 at 0.01 µg Lane 3 : ACE2 at 0.001 µg
Predicted band size : 92 kDa Observed band size : 116 kDa (why is the actual band size different from the predicted?) Additional bands at : 78 kDa (possible cleavage fragment). |
| |
| |
| Search PubMed (MEDLINE) for references to Angiotensin Converting Enzyme 2 |
| |
Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain - more information |
Customer reviews (feedback) regarding Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
Customer FAQs regarding Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
Protocols for Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
Price and availability of products related to Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
| |
Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain - related products: |
| |
| |
Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain - other tools: |
Contact Abcam with a Technical Enquiry about Angiotensin Converting Enzyme 2 antibody - Carboxyterminal end catalytic domain |
| |
All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"