  • Product overview

    The ELISPOT assay is designed to enumerate cytokine producing cells in a single cell suspension. This method has the advantage of requiring a minimum of in-vitro manipulations allowing cytokine production analysis as close as possible to in-vivo conditions in a highly specific way. This technique is designed to determine the frequency of cytokine producing cells under a given stimulation, and the follow-up of such frequency during a treatment and/or a pathological state. Elispot assay constitutes an ideal tool in the TH1 / TH2 response, vaccine development, viral infection monitoring and treatment, cancerology, infectious diseases, autoimmune diseases and transplantation.

    The Elispot assay is based on sandwich immuno-enzyme technology. Cell secreted cytokines or soluble molecules are captured by coated antibodies avoiding diffusion in supernatant, protease degradation or binding on soluble membrane receptors. After cell removal, the captured cytokines are revealed by tracer antibodies and appropriate conjugates.


    Principle

    After cell stimulation, locally produced cytokines are captured by IFN gamma and Granzyme B specific monoclonal antibodies. After cell lysis, trapped cytokine molecules are revealed by a secondary anti- IFN gamma FITC conjugated antibody and a biotinylated anti-Granzyme B antibody. Those are in turn recognised by anti-FITC green fluorescent dye and streptavidin-phycoerythrin conjugates. PVDF-bottomed-well plates are then read under a UV light beam. Green fluorescent spots indicate IFN gamma production while Granzyme B is revealed by red spots. Yellow spots will indicate dual cytokine producing cells.

  • Tested applications
    Suitable for: FluroSpotmore details
  • Platform
    Reagents

Properties

  • Storage instructions
    Store at +4°C. Please refer to protocols.
  • Components 5 x 96 tests 10 x 96 tests 15 x 96 tests 20 x 96 tests
    Anti-FITC antibody green fluorescence conjugate. 1 vial 2 vials 3 vials 4 vials
    Biotinylated detection antibody for Granzyme B (resuspend in 0.55mL). 1 x 1ml 2 x 1ml 3 x 1ml 4 x 1ml
    Bovine Serum Albumin 1 x 1g 2 x 1g 3 x 1g 4 x 1g
    Capture antibody for Granzyme B 1 x 500µl 2 x 500µl 3 x 500µl 4 x 500µl
    Human IFN? Capture antibody 1 x 500µl 2 x 500µl 3 x 500µl 4 x 500µl
    FITC conjugated detection antibody for IFNg (resuspend in 0.55mL) 1 vial 2 vials 3 vials 4 vials
    Fluorescence buffer 1 x 2.5ml 2 x 2.5ml 3 x 2.5ml 4 x 2.5ml
    Streptavidin-phycoerythrin conjugate. 1 vial 2 vials 3 vials 4 vials
  • Research areas
  • Relevance
    Interferon Gamma is produced by lymphocytes activated by specific antigens or mitogens. IFN-gamma, in addition to having antiviral activity, has important immunoregulatory functions. It is a potent activator of macrophages, it has antiproliferative effects on transformed cells and it can potentiate the antiviral and antitumor effects of the type I interferons. Granzyme B is necessary for target cell lysis in cell-mediated immune responses. It cleaves after Asp. Seems to be linked to an activation cascade of caspases (aspartate-specific cysteine proteases) responsible for apoptosis execution. Cleaves caspase-3, -7, -9 and 10 to give rise to active enzymes mediating apoptosis.
  • Alternative names
    • CSPB
    • Cytotoxic T lymphocyte proteinase 2
    • Granzyme 2
    • Granzyme B
    • GZMB
    • HLP
    • IFI
    • IFN gamma
    • IFNG
    • Immune interferon
    see all
  • Database links

Applications

Our Abpromise guarantee covers the use of ab48467 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
FluroSpot Use at an assay dependent dilution.

References

ab48467 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

There are currently no Customer reviews or Questions for ab48467.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"

Sign up