Mouse Axl Multiplex Immunoassay Kit (ab215151)

Overview

  • Product name
    Mouse Axl Multiplex Immunoassay Kit
    See all Axl kits
  • Detection method
    Flow cytometry-fluorescent
  • Precision
    Intra-assay
    Sample n Mean SD CV%
    Serum 3 5.4%
    Inter-assay
    Sample n Mean SD CV%
    Serum 3 8.7%
  • Sample type
    Cell culture supernatant, Urine, Serum, Heparin Plasma, EDTA Plasma, Citrate Plasma
  • Sensitivity
    5.82 pg/ml
  • Range
    41.1 pg/ml - 90000 pg/ml
  • Recovery

    Sample specific recovery
    Sample type Average % Range
    Cell culture supernatant 71 65% - 80%
    Serum 102 98% - 111%
    Heparin Plasma 80 74% - 85%
    EDTA Plasma 97 89% - 115%
    Citrate Plasma 95 86% - 105%

  • Species reactivity
    Reacts with: Mouse
  • Product overview

    Our multiplex immunoassays use the Firefly® particle technology to enable the quantitative measurement of many mouse proteins and peptides at the same time using as little as 12.5 μL of sample per well.
    The assay takes approximately 3.5 hours, followed by particle analysis using a validated flow cytometer model and then data analysis using our free Firefly Analysis Workbench software. 


    Benefits of the assays:
    - Save time and conserve samples by measuring many analytes at the same time in each sample.
    - Easily build the right panel for your experiment with simple custom panel assembly, convenient pre-mixed pre-designed panels and the ability to add new analytes to pre-designed panels.
    - Run sensitive & accurate assays, built around antibody pairs that are validated with appropriate biological samples.
    - Use one platform for both multiplex miRNA and multiplex immunoassays with Firefly particle-based assays.


    Find out more about Firefly particle-based multiplex immunoassays


    Important - Use of the Firefly Multiplex Immunoassay Kit also requires the purchase of:
    - a) A Mouse Multiplex Immunoassay Core Kit, ab209499; and
    - b) A Multiplex Immunoassay Protein Standard Mix such as ab215123.


    Firefly® is a registered trade mark in the United States and is registered as a European Union Trade Mark.

  • Notes

    The following information provides the sensitivity range and recommended starting dilutions for validated biological samples.

    Sensitivity range - 4.76 - 7.23 pg/mL

    Recommended Dilution Range
    Serum Plasma-Citrate Plasma-EDTA Plasma-Heparin Cell Culture Supernatant Urine
    1:4 1:4 1:4 1:4 1:4 1:4

     

Properties

Images

  • Mean background-subtracted data values are graphed. 

  • Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).  The mean Axl concentration was determined to be 110.4 ng/mL with a range of 68.6-205.1 ng/mL.                              

  • The concentrations of Axl were interpolated from the Axl standard curves and corrected for sample dilution. Undiluted samples are as follows:  serum 25%, plasma (citrate) 25%, plasma (EDTA) 25%, and plasma (heparin) 25%.  The interpolated dilution factor corrected mean values are plotted.  The mean Axl concentration was determined to be 101.4 ng/mL in serum, 72.4 ng/mL in plasma (citrate), 57.0 ng/mL in plasma (EDTA), and 65.0 ng/mL and in plasma (heparin).

  • Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2).  The concentrations of Axl were interpolated from the Axl standard curves and corrected for sample dilution. Undiluted samples are as follows:   25% male and female urine.  The interpolated dilution factor corrected mean values are plotted.  The mean Axl concentration was determined to be 53.3 pg/mL in female urine and 42.1 pg/mL in male urine.   

  • Interpolated concentrations of native Axl in splenocyte supernatants.  The concentrations of Axl were interpolated from the Axl standard curves and corrected for sample dilution. Undiluted samples are as follows:   25% splenocyte supernatants.  The interpolated dilution factor corrected mean values are plotted.  The mean Axl concentration was determined to be 5.3 pg/mL in unstimulated splenocyte and 4.6 pg/mL in PHA-stimulated splenocyte supernatants.

References

ab215151 has not yet been referenced specifically in any publications.