  • Product name
    DoubleStain IHC Kit: R&Rt on human/mouse tissue (DAB & AP/Red)
  • Assay type
    Polymer Multiplex
  • Product overview

    Abcam's Doublestain IHC Kit (ab183283) is designed for use with user supplied rabbit and rat primary antibodies to detect two distinct antigens on human and mouse tissue or cell samples. This kit has been tested on paraffin embedded tissue, however, it can also be used to stain frozen specimens and freshly prepared monolayer cell smears.

     

    Double staining is a common method used in immunohistostaining, allowing for the detection of two distinct antigens in a single tissue. This kit supplies the user with two polymer enzyme conjugates: Rat HRP polymer (minimal cross reaction to mouse) and Rabbit AP polymer with two distinct substrates/chromogens, DAB and Permanent Red. DAB chromogen reacts with the Rat HRP Polymer to produce a brown color. Permanent Red reacts with Rabbit AP Polymer to produce a red color. Abcam's Doublestain IHC Kit (ab183283) is a non-biotin system avoiding the extra steps involved in blocking non-specific binding due to endogenous biotin.

  • Tested applications
    Suitable for: IHC-Fr, IHC-Pmore details

Properties

  • Storage instructions
    Store at +4°C. Please refer to protocols.
  • Components 12 ml 36 ml 120 ml
    Aqueous Mounting Medium 1 x 15ml 2 x 18ml 1 x 120ml
    DAB Chromogen (20x) 1 x 1.5ml 1 x 2ml 1 x 6ml
    DAB Substrate 1 x 12ml 2 x 18ml 1 x 120ml
    Permanent Red Activator (5x) 1 x 3ml 1 x 7.2ml 2 x 12ml
    Permanent Red Chromogen (100x) 1 x 150µl 1 x 360µl 1 x 1.2ml
    Permanent Red Substrate 1 x 15ml 2 x 18ml 1 x 120ml
    Rabbit AP Polymer 1 x 6ml 1 x 18ml 1 x 60ml
    Rat HRP Polymer 1 x 6ml 1 x 18ml 1 x 60ml
  • Research areas

Applications

Our Abpromise guarantee covers the use of ab183283 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

Application Abreviews Notes
IHC-Fr Use at an assay dependent concentration.
IHC-P Use at an assay dependent concentration.

Protocols

References

ab183283 has not yet been referenced specifically in any publications.

Customer reviews and Q&As

DAB worked fine, AP/Red did not

Below average Excellent 5/5 (Ease of Use)
Abreviews
The reagents for the DAB protocol worked fine, but the AP/Red reagents never successfully produced any staining, above a very weak pink, even in positive control slides.