Skip to main content

ab169808 is for simultaneous detection of 23 Human Angiogenic Factors.

Be the first to review this product! Submit a review

Images

Multiplex Protein Detection - Human Angiogenesis Antibody Array - Membrane (23 targets) (AB169808), expandable thumbnail

Publications

Key facts

Assay type
Semi-quantitative
Reactive species
Human
Target
ANGPT1
(See target data below)

Target data

Function

Binds and activates TEK/TIE2 receptor by inducing its dimerization and tyrosine phosphorylation. Plays an important role in the regulation of angiogenesis, endothelial cell survival, proliferation, migration, adhesion and cell spreading, reorganization of the actin cytoskeleton, but also maintenance of vascular quiescence. Required for normal angiogenesis and heart development during embryogenesis. After birth, activates or inhibits angiogenesis, depending on the context. Inhibits angiogenesis and promotes vascular stability in quiescent vessels, where endothelial cells have tight contacts. In quiescent vessels, ANGPT1 oligomers recruit TEK to cell-cell contacts, forming complexes with TEK molecules from adjoining cells, and this leads to preferential activation of phosphatidylinositol 3-kinase and the AKT1 signaling cascades. In migrating endothelial cells that lack cell-cell adhesions, ANGT1 recruits TEK to contacts with the extracellular matrix, leading to the formation of focal adhesion complexes, activation of PTK2/FAK and of the downstream kinases MAPK1/ERK2 and MAPK3/ERK1, and ultimately to the stimulation of sprouting angiogenesis. Mediates blood vessel maturation/stability. Implicated in endothelial developmental processes later and distinct from that of VEGF. Appears to play a crucial role in mediating reciprocal interactions between the endothelium and surrounding matrix and mesenchyme.

Additional Targets

ANGPT2, PLG, COL18A1, CSF3, CSF2, CCL1, IL1A, IL1B, IL10, IL2, IL4, CXCL11, CCL7, CCL13, MMP1, PECAM1, TEK, TNF, PLAUR, KDR, FLT4

Alternative names

What's included?

1 x 8 Membranes
Components
1,000X HRP-Conjugated Streptavidin
1 x 50 µL
1X Blocking Buffer
2 x 25 mL
20X Wash Buffer I
1 x 20 mL
20X Wash Buffer II
1 x 20 mL
2X Cell Lysis Buffer
1 x 16 mL
8-Well Incubation Tray (with Lid)
1 x 1 Unit
Biotinylated Antibody Cocktail (C2)
4 x 1 Vial
Detection Buffer C
1 x 2.5 mL
Detection Buffer D
1 x 2.5 mL
Human Angiogenesis Antibody Array Membranes (C2)
2 x 4 Unit
Plastic sheets
1 x 1 Unit

Recommended products

ab169808 is for simultaneous detection of 23 Human Angiogenic Factors.

Key facts

Assay type
Semi-quantitative
Reactive species
Human
Target
ANGPT1
Applications
Multiplex Protein Detection
Detection method
Luminescent
Sample types
Saliva, Urine, Plasma, Cell culture extracts, Tissue Extracts, Cell culture media, Cell culture supernatant, Milk, Serum, Other biological fluids, Whole Blood, Cell Lysate

Storage

Shipped at conditions
Blue Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Notes

ab169808 is for simultaneous detection of 23 Human Angiogenic Factors. Suitable for all liquid sample types.

Targets: Angiopoietin 1, Angiopoietin 2, Angiostatin, Endostatin, G-CSF, GM-CSF, I-309, IL-10, IL-1 alpha, IL-1 beta, IL-2, IL-4, I-TAC, MCP-3, MCP-4, MMP-1, MMP-9, PECAM-1, Tie-2, TNF alpha, uPAR, VEGFR2, VEGFR3

Cytokine arrays are an antibody-pair-based assay, analogous to ELISA, but using a membrane as a substrate rather than a plate. Capture antibodies are supplied arrayed/spotted on a membrane with each pair of spots representing a different analyte. Sample is added (0.2-1ml of 1 sample to each membrane), and then paired biotinylated detector antibodies and streptavidin HRP. The cytokine array is analyzed using the same methods as a chemiluminescent western blot. Comparison between samples can be by eye or using densitometry software for a semi-quantitative comparison.


**A table listing all of our human membrane antibody cytokine arrays and other arrays and the analytes they measure is available .**"


Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.

Product promise

We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.

In the unlikely event of one of our products not working as expected, you are covered by our product promise.

Full details and terms and conditions can be found here:
Terms & Conditions.

1 product image

  • Multiplex Protein Detection - Human Angiogenesis Antibody Array - Membrane (23 targets) (ab169808), expandable thumbnail

    Multiplex Protein Detection - Human Angiogenesis Antibody Array - Membrane (23 targets) (ab169808)

    Typical results obtained with Abcam Membrane Antibody Arrays. These membranes were probed with conditioned media from two different cell lines. Membranes were exposed to film at room temperature for 1 minute.

Downloads

Product protocols

For this product, it's our understanding that no specific protocols are required. You can:

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com