JavaScript is disabled in your browser. Please enable JavaScript to view this website.

Fixation and permeabilization buffers

Reduce preparation time with easy-to-use fixation and permeabilization buffers optimized for flow cytometry. Part of a portfolio of over 250 application reagents with 4.5k+ citations, these buffers are compatible with a wide range of antibodies and cell types to ensure consistent experimental results.
Browse Fix & Perm buffers
button-secondary

What are fixation and permeabilization buffers?

Also known as fix & perm buffers, these specialized reagents are designed to optimize the preparation of cells for immunophenotyping via flow cytometry. These buffers simplify the processes of cell fixation and cell permeabilization, making them essential tools for researchers studying intracellular processes. They maintain cell morphology and antigen integrity, ensuring high-quality staining and reliable results.

Why are fixation and permeabilization important in flow cytometry?

Fixation and permeabilization buffers help researchers investigate:

These workflows can provide a more complete picture of cellular activity than surface marker analysis alone. In many studies, researchers combine surface and intracellular staining to identify specific cell populations while simultaneously examining their functional state.

Properly preparing the sample is particularly important for generating reliable data, as antigen integrity helps reduce variability and improve staining quality.

Read our fix & perm for flow cytometry guide and flow cytometry troubleshooting guide.

Key features

Enhanced cell preservation

Fixation and permeabilization buffers stabilize cell structures and antigens, enabling accurate identification and analysis.

Compatibility

We’ve designed these kits to integrate seamlessly with a wide range of antibodies and reagents from our flow cytometry portfolio, allowing you to achieve consistent, reliable results without extra steps.

Ease of use

Simplifies the sample preparation workflow, reducing the steps required to prepare cells for analysis.

Specifications

Formulation

Each buffer is formulated to maintain optimum pH and ionic strength for antibody binding.

Packaging

Available in various volumes to suit different research scale needs, from small to large batches.

Benefits

Applications and use cases

Fix & perm buffers are invaluable in multiple research scenarios:

Cancer research

Facilitate the identification of cancerous cells and understand their mechanisms by allowing detailed analysis of intracellular and surface antigens.

Infectious disease research

Aid in the characterization of host-pathogen interactions by permitting the simultaneous staining of surface and internal markers.

Cell signaling studies

Allow for the investigation of signal transduction pathways involving intracellular cytokines and other proteins.

Intracellular proteins

Intracellular proteins provide important information about cell function, activation status, and biological responses that can’t be determined from surface markers alone. Located within the cytoplasm, nucleus, or other internal cellular compartments, these proteins require fixation and permeabilization before they can be detected by flow cytometry.

Intracellular proteins are analyzed to investigate immune responses, cellular signaling pathways, and mechanisms of disease. Depending on the application, targets may include:

Intracellular cytokine staining is particularly valuable because it enables researchers to measure cytokine production at the single-cell level while simultaneously identifying the cell population responsible for the response.

The choice of fixation and permeabilization strategy can influence staining performance, as different intracellular targets may require different preparation conditions. For example, cytoplasmic proteins, nuclear transcription factors, and phosphoproteins can each require specific buffer systems to preserve target accessibility and staining quality.

By enabling access to intracellular targets, fix and perm buffers expand the analytical capabilities of flow cytometry beyond cell identification alone, helping researchers gain deeper insights into cellular activity, immune function, and biological processes.

Staining protocol

Successful flow cytometry experiments depend on careful sample preparation and staining conditions. While individual protocols may vary according to cell type, target antigen, and antibody panel, most staining workflows follow a series of key preparation steps designed to maximize signal quality and minimize background staining.

For experiments involving both surface and intracellular targets, surface staining is generally performed first while cell membranes remain intact. Cells are then fixed to preserve cellular structures and target proteins, followed by permeabilization to allow antibodies access to intracellular antigens. After intracellular staining, excess reagents are removed through washing steps before the samples are acquired on a flow cytometer.

A standard intracellular staining protocol for flow cytometry generally includes:

  1. Prepare and wash the cell sample.
  2. Stain cell surface markers where required.
  3. Fix cells to preserve morphology and antigen integrity.
  4. Permeabilize the cells to enable intracellular antibody access.
  5. Incubate with antibodies against intracellular targets.
  6. Wash to remove unbound antibodies and reduce background signal.
  7. Resuspend the cells in an appropriate buffer for flow cytometry analysis.

Careful optimization of antibody concentrations, incubation times, and washing conditions can help improve staining consistency and data quality. Using validated fixation and permeabilization reagents can also support reproducible results across different cell types and applications, particularly in multiparameter flow cytometry experiments where both surface and intracellular markers are being analyzed.

By following a structured staining protocol, researchers can generate reliable data while preserving the biological information needed to accurately characterize cell populations and cellular function.

View all flow cytometry buffers, reagents & equipment.

FAQ

What types of cells can be processed with fix and perm buffers?

Fix and perm buffers are versatile and can be used with a wide range of cell types, including peripheral blood mononuclear cells, cultured cells, and tissue-derived cells.

Can fix and perm buffers be used with all antibodies?

These buffers are designed to be compatible with a wide array of antibodies used in flow cytometry, but it's advisable to check specific antibody recommendations.

How do fix and perm buffers impact cell viability?

These buffers are intended for use in assays where cell viability post-treatment is not a concern, as the fixation process compromises cell viability.

Are these buffers suitable for multiplex applications?

Yes, fix and perm buffers facilitate multiplex staining by allowing access to both surface and intracellular antigens without compromising the staining quality of either.

We’ve created our fix and perm buffers to make flow cytometry prep easier and more consistent. With fewer steps and reliable performance, they help you achieve clear results, fast.

Explore fix and perm buffers

Browse now
button-primary