There are a variety of parameters that can be used to monitor cell viability.
1 Images
Functional Studies - Cell Viability Assay Kit (Fluorometric - Green) (AB112122)
  • FuncS

Supplier Data

Functional Studies - Cell Viability Assay Kit (Fluorometric - Green) (AB112122)

CHO-K1 cell number response was measured with ab112122. CHO-K1 cells at 0 to 5,000 cells/well/100 µL were seeded overnight in a black wall/clear bottom 96-well plate. The cells were incubated with 100 µL/well of Green dye-loading solution for 1 hour at 37 °C. The fluorescence intensity was measured at Ex/Em = 490/ 525 nm. The fluorescence intensity was linear (R2 = 1) to the cell number as indicated. The detection limit was 30 cells/well (n=6).

Key facts

Detection method

Fluorescent

Sample types

Suspension cells, Adherent cells

Assay type

Quantitative

Assay Platform

Microplate reader, Fluor. microscope, Flow cyt.

Product details

There are a variety of parameters that can be used to monitor cell viability. The green fluorescent dye used in the kit is a hydrophobic compound. It easily permeates intact live cells and gets enhanced fluorescence upon entering into live cells. The hydrolysis of the non-fluorescent substrate by intracellular esterases generates a strongly green fluorescent hydrophilic product that is well-retained in the cell cytoplasm. The green fluorophore generated by the non-fluorescent substrate used in the kit has the spectral properties of fluorescein at Ex/Em = ~490 nm/520 nm. When well excited with the Argon Laser at 488 nm, the fluorophore emits intense green fluorescence at ~520 nm.ab112122 provides all the essential components with an optimized cell-labeling protocol for fluorescence microplate assays. It can also be used with a fluorescence microscope equipped with a FITC filter set.ab112122 provides an effective tool of labeling cells for fluorescence microplate and microscopic investigations of cellular functions. It is useful for a variety of studies, including cell adhesion, chemotaxis, multidrug resistance, cell viability, apoptosis and cytotoxicity. ab112122 is suitable for proliferating and non-proliferating cells. Visit our for tips and troubleshooting.

Review the to learn about more kits to perform a , and .

What's included?

{ "values": { "5x96Tests": { "sellingSize": "5 x 96 Tests", "publicAssetCode":"ab112122-5x96Tests", "assetComponentDetails": [ { "size":"1 x 50 mL", "name":"Assay Buffer", "number":"AB112122-CMP01", "productcode":"" }, { "size":"5 x 1 Vial", "name":"CellGreen fluorescent dye", "number":"AB112122-CMP03", "productcode":"" }, { "size":"1 x 200 µL", "name":"DMSO", "number":"AB112122-CMP02", "productcode":"" } ] } } }

Properties and storage information

Shipped at conditions
Blue Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Product protocols

Target data

Publications (2)

Recent publications for all applications. Explore the full list and refine your search

Investigative radiology 58:388-395 PubMed36729074

2023

Multimodal In Vivo Tracking of Chimeric Antigen Receptor T Cells in Preclinical Glioblastoma Models.

Applications

Unspecified application

Species

Unspecified reactive species

Wei Emma Wu,Edwin Chang,Linchun Jin,Shiqin Liu,Ching-Hsin Huang,Rozy Kamal,Tie Liang,Nour Mary Aissaoui,Ashok J Theruvath,Laura Pisani,Michael Moseley,Tanya Stoyanova,Ramasamy Paulmurugan,Jianping Huang,Duane A Mitchell,Heike E Daldrup-Link

iScience 25:103770 PubMed35146387

2022

Establishment of a developmental toxicity assay based on human iPSC reporter to detect FGF signal disruption.

Applications

Unspecified application

Species

Unspecified reactive species

Seiya Kanno,Yusuke Okubo,Tatsuto Kageyama,Lei Yan,Satoshi Kitajima,Junji Fukuda
View all publications
websiteProtocolBooklet
en

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com