Skip to main content

Intracellular Oxygen Concentration Assay (ab197245) is an easy mix and measure 96 well fluorescence plate reader based approach for the analysis of intracellular oxygen concentration at the cell monolayer.

Be the first to review this product! Submit a review

Images

Cellular Activity - Intracellular Oxygen Concentration Assay (AB197245), expandable thumbnail
  • Cellular Activity - Intracellular Oxygen Concentration Assay (AB197245), expandable thumbnail
  • Cellular Activity - Intracellular Oxygen Concentration Assay (AB197245), expandable thumbnail
  • Cellular Activity - Intracellular Oxygen Concentration Assay (AB197245), expandable thumbnail
  • Cellular Activation - Intracellular Oxygen Concentration Assay (AB197245), expandable thumbnail

Publications

Key facts

Detection method
Fluorescent
Sample types
Adherent cells, Suspension cells
Assay type
Quantitative
Reactive species
Human
Assay time
1h 30m

What's included?

96 Test
Components
Intracellular O2 probe
1 x 1 Vial

Recommended products

Intracellular Oxygen Concentration Assay (ab197245) is an easy mix and measure 96 well fluorescence plate reader based approach for the analysis of intracellular oxygen concentration at the cell monolayer.

Key facts

Detection method
Fluorescent
Sample types
Adherent cells, Suspension cells
Assay type
Quantitative
Reactive species
Human
Assay time
1h 30m
Assay Platform
Microplate reader

Storage

Shipped at conditions
Blue Ice
Appropriate short-term storage conditions
+4°C
Appropriate long-term storage conditions
+4°C
Storage information
+4°C

Notes

Intracellular Oxygen Concentration Assay (ab197245) is an easy mix and measure 96 well fluorescence plate reader based approach for the analysis of intracellular oxygen concentration at the cell monolayer. The assay is based on the ability of oxygen to quench the excited state of the oxygen-sensitive probe. The probe is taken up via nonspecific energy dependent endocytosis and, after washing, the cells are monitored on a fluorescence plate reader (dual-read TR-F required for full oxygen quantitation). The probe phosphorescence is quenched by intracellular oxygen in a non-chemical, reversible manner allowing the measurement of average intracellular O2 levels and facilitating real-time monitoring of relative changes in cellular oxygen consumption. The probe signal increases with a reduction in intracellular oxygen and deceases with an increase in intracellular oxygen. The probe is excitable at 360-400 or 535 nm and emits at 630-680 nm. Optimal filter combinations are Ex/Em = 340/642 nm.

The flexible plate reader format, allows multiparametric or multiplex combination with a range of other reagents and it is suitable for HTP automation.

Learn more about the full range of . Or review the full for other assays for metabolites, metabolic enzymes, mitochondrial function, and oxidative stress.

Product promise

We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.

In the unlikely event of one of our products not working as expected, you are covered by our product promise.

Full details and terms and conditions can be found here:
Terms & Conditions.

6 product images

  • Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245)

    Excitation and emission spectra of O2 probe.

    Excitation and Emission spectra of Intracellular O2 probe, showing normalized excitation (Ex 360-400nm; Peak 380nm) and emission (Em 630-670nm; Peak 650nm).

  • Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245)

  • Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245)

    HEK293T cell oxygenation. HEK293T cells were cultured in 2D and measured at ambient oxygen. Intracellular O2 levels were ~ 14%. Reducing instrument O2 to 6% caused cellular oxygenation to drop to ~2%. Assay performed using a CLARIOstart equipped with an ACU module (BMG Labtech).

  • Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activity - Intracellular Oxygen Concentration Assay (ab197245)

    Sample callibration data.

    Sample Calibration Data. Intra O2 probe Lifetime profiles measured at decreasing [O2] with parallel glucose oxidase treatment to achieve 0% O2.

  • Cellular Activation - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activation - Intracellular Oxygen Concentration Assay (ab197245)

    Relationship between probe lifetime (τ) and applied [O2].

    Relationship between probe lifetime (τ) and applied [O2]. Applying a first order exponential fit generates a calibration function of O2% = A1 x Exp(-τ / t1). Example: O2% = 659.3 x Exp(-τ / 8.475).

  • Cellular Activation - Intracellular Oxygen Concentration Assay (ab197245), expandable thumbnail

    Cellular Activation - Intracellular Oxygen Concentration Assay (ab197245)

    Measuring the impact of cell metabolism on iPS-derived cardiomyocyte oxygenation. During measurement, cells are treated with antimycin (ETC inhibitor) and isoproterenol (β-adrenoreceptor agonist).

Downloads

Product protocols

For this product, it's our understanding that no specific protocols are required. You can:

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com