Alexa Fluor® 594 Conjugation Kit (Fast) - Lightning-Link® (ab269822) offers several standout features:

- Rapid Conjugation: achieve Alexa Fluor® 594 labeling in under 20 minutes with just 30 seconds of hands-on time.
- High Efficiency: ensures 100% antibody recovery, meaning no loss of valuable antibodies.
- Versatility: suitable for conjugating antibodies, proteins, and peptides. Alexa Fluor® 594 labeled antibodies can be used immediately in applications such as Western blot (WB), ELISA, and Immunohistochemistry (IHC) without further purification.
1 Images
Schematic Diagram - Alexa Fluor® 594 Conjugation Kit (Fast) - Lightning-Link® (AB269822)
  • Schematic Diagram

Supplier Data

This illustration demonstrates a general procedure of how the Lightning-Link®(Fast) labeling technology enables the direct labeling of antibodies or proteins.

Simply pipette your antibody or biomolecule of choice into the vial of a lyophilized mixture containing the label of interest and incubate for just 15 minutes. Please see the ab269822 protocol booklet for more details.

Learn more about our Lightning-Link® conjugation kits here

Key facts

Product details

Alexa Fluor® 594 Conjugation Kit (Fast) - Lightning-Link® (ab269822) uses a simple and quick process for labeling / conjugation of antibodies. It can also be used to conjugate other proteins or peptides.

To conjugate an antibody to Alexa Fluor® 594 using this kit:
- add modifier to antibody and incubate for 15 min
- add quencher and incubate for 5 min

The Alexa Fluor® 594 conjugated antibody can be used immediately in Flow cytometry, WB, ELISA, IHC etc. No further purification is required and 100% of the antibody is recovered for use.

Learn about our antibody labeling kits and their advantages here.

Learn about buffer compatibility below; for incompatible buffers and low antibody concentrations, use our antibody purification and concentration kits.
Custom size conjugation kits up to 100 mg are available on demand. Please contact us to discuss your requirements.

Amount and volume of antibody for conjugation to Alexa Fluor® 594

Kit size Recommended
amount of antibody1
Maximum
amount of antibody
Maximum antibody
volume2
3 x 10 µg 3 x 10 µg 3 x 20 µg 3 x 10 µL
100 µg 100 µg 200 µg 100 µL
3 x 100 µg 3 x 100 µg 3 x 200 µg 3 x 100 µL
1 mg 1 x 1 mg 1 x 2 mg 1 x 1 mL

1 Using the maximum amount of antibody may result in less labelling per antibody.

2 Ideal antibody concentration is 1mg/mL. 0.5 - 1 mg/mL can be used if the maximum antibody volume is not exceeded. Antibodies > 2mg/mL or < 0.5 mg/mL should be diluted /concentrated.

Buffer Requirements for Conjugation

Buffer should be pH 6.5-8.5.

Compatible buffer constituents
If a concentration is shown, then the constituent should be no more than the concentration shown. If several constituents are close to the limit of acceptable concentration, then this can inhibit conjugation.

50mM / 0.6% Tris1 0.1% BSA2 50% glycerol
0.1% sodium azide PBS Potassium phosphate
Sodium chloride HEPES Sucrose
Sodium citrate EDTA Trehalose

1 Tris buffered saline is almost always ≤ 50 mM / 0.6%
2 BSA can also interfere with the use of the conjugated antibody in tissue staining.

Incompatible buffer constituents

Thiomerosal Proclin Glycine
Arginine Glutathione DTT

If a constituent of the buffer containing your antibody or protein is not listed above, please contact us.

Only purified antibodies are suitable for use, ie. where other proteins, peptides, or amino acids are not present: antibodies in ascites fluid, serum or hybridoma culture media are incompatible.

Storing and handling conjugation kits

Lyophilized Lightning-Link® components are hygroscopic.

Kits are intentionally shipped at ambient temperature with silica gel to avoid exposure to moisture. Upon receipt, store the kit frozen and protect from moisture. Before opening the outer container, allow the lyophilized components to reach room temperature to minimize condensation.

This product is manufactured by Expedeon, an Abcam company, and was previously called Lightning-Link® Rapid Alexa Fluor® 594 Labeling Kit. 335-0015 is the same as the 1 mg size. 335-0010 is the same as the 3 x 100 µg size. 335-0030 is the same as the 3 x 10 µg size. 335-0005 is the same as the 100 µg size.

Alexa Fluor® is a registered trademark of Molecular Probes, Inc, a Thermo Fisher Scientific Company. The Alexa Fluor® dye included in this product is provided under an intellectual property license from Life Technologies Corporation. As this product contains the Alexa Fluor® dye, the purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). As this product contains the Alexa Fluor® dye the sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: in manufacturing; (ii) to provide a service, information, or data in return for payment (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are sold for use in research. For information on purchasing a license to this product for purposes other than research, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.

What's included?

{ "values": { "3x10g": { "sellingSize": "3 x 10 µg", "publicAssetCode":"ab269822-3x10ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269822-CMP03" }, { "size":"3 x 10 µg", "name":"Alexa Fluor 594® mix (Lyophilized)", "number":"AB269822-CMP01" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269822-CMP02" } ] }, "3x100g": { "sellingSize": "3 x 100 µg", "publicAssetCode":"ab269822-3x100ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269822-CMP03" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269822-CMP02" }, { "size":"3 x 100 µg", "name":"Alexa Fluor 594® mix (Lyophilized)", "number":"AB269822-CMP01" } ] }, "1mg": { "sellingSize": "1 mg", "publicAssetCode":"ab269822-1mg", "assetComponentDetails": [ { "size":"1 x 1 mg", "name":"Alexa Fluor 594® mix (Lyophilized)", "number":"AB269822-CMP01" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269822-CMP02" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269822-CMP03" } ] }, "100g": { "sellingSize": "100 µg", "publicAssetCode":"ab269822-100ug", "assetComponentDetails": [ { "size":"1 x 100 µg", "name":"Alexa Fluor 594® mix (Lyophilized)", "number":"AB269822-CMP01", "productcode":"" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269822-CMP02", "productcode":"" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269822-CMP03", "productcode":"" } ] } } }

Properties and storage information

Shipped at conditions
Ambient - Cannot Ship with Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Product protocols

Target data

Publications (11)

Recent publications for all applications. Explore the full list and refine your search

Advanced healthcare materials 14:e2401192 PubMed38837879

2024

T Cells Spatially Regulate B Cell Receptor Signaling in Lymphomas through H3K9me3 Modifications.

Applications

Unspecified application

Species

Unspecified reactive species

Lucy S Britto,Deepali Balasubramani,Sona Desai,Phunterion Phillips,Neev Trehan,Ethel Cesarman,Jean L Koff,Ankur Singh

Antioxidants (Basel, Switzerland) 12: PubMed38136165

2023

Extracellular Vesicles and Their Renin-Angiotensin Cargo as a Link between Metabolic Syndrome and Parkinson's Disease.

Applications

Unspecified application

Species

Unspecified reactive species

Maria A Pedrosa,Carmen M Labandeira,Nerea Lago-Baameiro,Rita Valenzuela,Maria Pardo,Jose Luis Labandeira-Garcia,Ana I Rodriguez-Perez

Alzheimer's & dementia : the journal of the Alzheimer's Association 20:819-836 PubMed37791598

2023

APOE Christchurch-mimetic therapeutic antibody reduces APOE-mediated toxicity and tau phosphorylation.

Applications

Unspecified application

Species

Unspecified reactive species

Claudia Marino,Paula Perez-Corredor,Michael O'Hare,Annie Heuer,Natalia Chmielewska,Harper Gordon,Anita S Chandrahas,Lucia Gonzalez-Buendia,Santiago Delgado-Tirado,Tri H Doan,Timothy E Vanderleest,Said Arevalo-Alquichire,Robert A Obar,Carolina Ortiz-Cordero,Andres Villegas,Diego Sepulveda-Falla,Leo A Kim,Francisco Lopera,Robert Mahley,Yadong Huang,Yakeel T Quiroz,Joseph F Arboleda-Velasquez

Analytical methods : advancing methods and applications 15:3483-3489 PubMed37424294

2023

Development of a cellulose-based 96-well plate vertical flow pull-down assay.

Applications

Unspecified application

Species

Unspecified reactive species

Hoi Lok Cheng,Huan Jia,Sing Mei Lim,Say Yong Ng,Patthara Kongsuphol,Megan E McBee,Hadley D Sikes

Frontiers in veterinary science 10:1117591 PubMed36816182

2023

Stage of infection with subsp. impacts expression of Rab5, Rab7, and CYP27B1 in macrophages within the ileum of naturally infected cows.

Applications

Unspecified application

Species

Unspecified reactive species

Taylor L T Wherry,Mark Heggen,Adrienne L Shircliff,Shankumar Mooyottu,Judith R Stabel

Frontiers in immunology 13:946643 PubMed36177009

2022

Human differentiated eosinophils release IL-13 in response to IL-33 stimulation.

Applications

Unspecified application

Species

Unspecified reactive species

Amiko M Uchida,Gabrielle Ro,Li Qiang,Kathryn A Peterson,June Round,Michael Dougan,Stephanie K Dougan

Clinical chemistry 68:668-679 PubMed35348673

2022

ALK-Fusion Transcripts Can Be Detected in Extracellular Vesicles (EVs) from Nonsmall Cell Lung Cancer Cell Lines and Patient Plasma: Toward EV-Based Noninvasive Testing.

Applications

Unspecified application

Species

Unspecified reactive species

Estela Sánchez-Herrero,Carmen Campos-Silva,Yaiza Cáceres-Martell,Lucía Robado de Lope,Sandra Sanz-Moreno,Roberto Serna-Blasco,Alejandro Rodríguez-Festa,Dunixe Ares Trotta,Paloma Martín-Acosta,Cristina Patiño,María José Coronado,Alexandra Beneitez,Ricardo Jara,Nerea Lago-Baameiro,Tamara Camino,Alberto Cruz-Bermúdez,María Pardo,Víctor González-Rumayor,Mar Valés-Gómez,Mariano Provencio,Atocha Romero

Bioengineering & translational medicine 7:e10293 PubMed35600666

2022

Finger stick blood test to assess postvaccination SARS-CoV-2 neutralizing antibody response against variants.

Applications

Unspecified application

Species

Unspecified reactive species

Sing Mei Lim,Hoi Lok Cheng,Huan Jia,Patthara Kongsuphol,Bhuvaneshwari D/O Shunmuganathan,Ming Wei Chen,Say Yong Ng,Xiaohong Gao,Shuvan Prashant Turaga,Sascha P Heussler,Jyoti Somani,Sharmila Sengupta,Dousabel M Y Tay,Megan E McBee,Barnaby E Young,Paul A MacAry,Hadley D Sikes,Peter R Preiser

Basic research in cardiology 116:25 PubMed33847835

2021

SKI activates the Hippo pathway via LIMD1 to inhibit cardiac fibroblast activation.

Applications

Unspecified application

Species

Unspecified reactive species

Natalie M Landry,Sunil G Rattan,Krista L Filomeno,Thomas W Meier,Simon C Meier,Sarah J Foran,Claire F Meier,Navid Koleini,Robert R Fandrich,Elissavet Kardami,Todd A Duhamel,Ian M C Dixon

Cell reports 27:3972-3987.e6 PubMed31242427

2019

Physical and Molecular Landscapes of Mouse Glioma Extracellular Vesicles Define Heterogeneity.

Applications

Unspecified application

Species

Unspecified reactive species

Aron Gyuris,Jose Navarrete-Perea,Ala Jo,Simona Cristea,Shuang Zhou,Kyle Fraser,Zhiyun Wei,Anna M Krichevsky,Ralph Weissleder,Hakho Lee,Steve P Gygi,Al Charest
View all publications
websiteProtocolBooklet
en
websiteProtocolBooklet
zh

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com