JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB201797

Dylight® 350 Conjugation Kit (Fast) - Lightning-Link®

Be the first to review this product! Submit a review

|

(3 Publications)

Dylight® 350 Conjugation Kit (Fast) - Lightning-Link® (ab201797) offers several standout features:

- Rapid Conjugation: achieve Dylight® 350 labeling in under 20 minutes with just 30 seconds of hands-on time.
- High Efficiency: ensures 100% antibody recovery, meaning no loss of valuable antibodies.
- Versatility: suitable for conjugating antibodies, proteins, and peptides. Dylight® 350 labeled antibodies can be used immediately in applications such as Flow cytometry, ELISA, and Immunohistochemistry (IHC) without further purification.
1 Images
Schematic Diagram - Dylight® 350 Conjugation Kit (Fast) - Lightning-Link® (AB201797)
  • Schematic Diagram

Supplier Data

This illustration demonstrates a general procedure of how the Lightning-Link®(Fast) labeling technology enables the direct labeling of antibodies or proteins.

Simply pipette your antibody or biomolecule of choice into the vial of a lyophilized mixture containing the label of interest and incubate for just 15 minutes. Please see the ab201797 protocol booklet for more details.

Learn more about our Lightning-Link® conjugation kits here

Key facts

Product details

DyLight® 350 Conjugation Kit (Fast) - Lightning-Link® (ab201797) uses a simple and quick process for labeling / conjugation of antibodies. It can also be used to conjugate other proteins or peptides.

To conjugate an antibody to DyLight® 350 using this kit:
- add modifier to antibody and incubate for 15 min
- add quencher and incubate for 5 min

The DyLight® 350 conjugated antibody can be used immediately in Flow cytometry, WB, ELISA, IHC etc. No further purification is required and 100% of the antibody is recovered for use.

Learn about our antibody labeling kits and their advantages here.

Learn about buffer compatibility below; for incompatible buffers and low antibody concentrations, use our antibody purification and concentration kits.
Custom size conjugation kits up to 100 mg are available on demand. Please contact us to discuss your requirements.

Amount and volume of antibody for conjugation to Dylight® 350

Kit size Recommended
amount of antibody1
Maximum
amount of antibody
Maximum antibody
volume2
3 x 10 µg 3 x 10 µg 3 x 20 µg 3 x 10 µL
100 µg 1 x 100 µg 1 x 200 µg 1 x 100 µL
3 x 100 µg 3 x 100 µg 3 x 200 µg 3 x 100 µL
1 mg 1 x 1 mg 1 x 2 mg 1 x 1 mL

1 Using the maximum amount of antibody may result in less labelling per antibody.

2 Ideal antibody concentration is 1mg/ml. 0.5 - 1 mg/ml can be used if the maximum antibody volume is not exceeded. Antibodies > 2 mg/mL or < 0.5 mg/ml should be diluted /concentrated.

Buffer Requirements for Conjugation

Buffer should be pH 6.5-8.5.

Compatible buffer constituents
If a concentration is shown, then the constituent should be no more than the concentration shown. If several constituents are close to the limit of acceptable concentration, then this can inhibit conjugation.

50mM / 0.6% Tris1 0.1% BSA2 50% glycerol
0.1% sodium azide PBS Potassium phosphate
Sodium chloride HEPES Sucrose
Sodium citrate EDTA Trehalose

1 Tris buffered saline is almost always ≤ 50 mM / 0.6%
2 BSA can also interfere with the use of the conjugated antibody in tissue staining.

Incompatible buffer constituents

Thiomerosal Proclin Glycine
Arginine Glutathione DTT

If a constituent of the buffer containing your antibody or protein is not listed above, please contact us.

Only purified antibodies are suitable for use, ie. where other proteins, peptides, or amino acids are not present: antibodies in ascites fluid, serum or hybridoma culture media are incompatible.

Storing and handling conjugation kits

Lyophilized Lightning-Link® components are hygroscopic.

Kits are intentionally shipped at ambient temperature with silica gel to avoid exposure to moisture. Upon receipt, store the kit frozen and protect from moisture. Before opening the outer container, allow the lyophilized components to reach room temperature to minimize condensation.

This product is manufactured by Expedeon, an Abcam company, and was previously called Lightning-Link® Rapid DyLight® 350 Labeling Kit. 320-0015 is the same as the 1 mg size. 320-0010 is the same as the 3 x 100 µg size. 320-0030 is the same as the 3 x 10 µg size. 320-0005 is the same as the 100 µg size.

What's included?

{ "values": { "3x10g": { "sellingSize": "3 x 10 µg", "publicAssetCode":"ab201797-3x10ug", "assetComponentDetails": [ { "size":"3 x 10 µg", "name":"Dylight® 350 Conjugation Mix", "number":"AB201797-CMP01" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201797-CMP02" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201797-CMP03" } ] }, "3x100g": { "sellingSize": "3 x 100 µg", "publicAssetCode":"ab201797-3x100ug", "assetComponentDetails": [ { "size":"3 x 100 µg", "name":"Dylight® 350 Conjugation Mix", "number":"AB201797-CMP01" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201797-CMP03" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201797-CMP02" } ] }, "1mg": { "sellingSize": "1 mg", "publicAssetCode":"ab201797-1mg", "assetComponentDetails": [ { "size":"1 x 1 mg", "name":"Dylight® 350 Conjugation Mix", "number":"AB201797-CMP01" }, { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201797-CMP02" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201797-CMP03" } ] }, "100g": { "sellingSize": "100 µg", "publicAssetCode":"ab201797-100ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB201797-CMP02", "productcode":"" }, { "size":"1 x 100 µg", "name":"Dylight® 350 Conjugation Mix", "number":"AB201797-CMP01", "productcode":"" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB201797-CMP03", "productcode":"" } ] } } }

Properties and storage information

Shipped at conditions
Ambient - Cannot Ship with Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Product protocols

Target data

Publications (3)

Recent publications for all applications. Explore the full list and refine your search

Journal of diabetes research 2022:3555889 PubMed35399705

2022

Mitochondrial Dynamics in the Metabolic Memory of Diabetic Retinopathy.

Applications

Unspecified application

Species

Unspecified reactive species

Ghulam Mohammad,Renu A Kowluru

JCI insight 2:e90626 PubMed28239654

2017

Flow virometric sorting and analysis of HIV quasispecies from plasma.

Applications

Unspecified application

Species

Unspecified reactive species

Thomas Musich,Jennifer C Jones,Brandon F Keele,Lisa M Miller Jenkins,Thorsten Demberg,Thomas S Uldrick,Robert Yarchoan,Marjorie Robert-Guroff

Forensic science international 232:173-9 PubMed24053878

2013

Simultaneous labeling of multiple components in a single fingermark.

Applications

Unspecified application

Species

Unspecified reactive species

Annemieke van Dam,Maurice C G Aalders,Kevin van de Braak,Huub J J Hardy,Ton G van Leeuwen,Saskia A G Lambrechts
View all publications
websiteProtocolBooklet
en
websiteProtocolBooklet
zh

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com