AB102887

Glucose Oxidase Conjugation Kit - Lightning-Link®

Be the first to review this product! Submit a review

|

(9 Publications)

Glucose Oxidase Conjugation Kit - Lightning-Link® (ab102887) offers several standout features:

- Rapid Conjugation: achieve Glucose Oxidase (GOx) labeling in under 4 hours with just 30 seconds of hands-on time.
- High Efficiency: ensures 100% antibody recovery, meaning no loss of valuable antibodies.
- Versatility: suitable for conjugating antibodies, proteins, and peptides. GOx-labeled antibodies can be used immediately in applications such as Western blot, ELISA, and Immunohistochemistry (IHC) without further purification.
1 Images
Schematic Diagram - Glucose Oxidase Conjugation Kit - Lightning-Link® (AB102887)
  • Schematic Diagram

Supplier Data

This illustration demonstrates a general procedure of how Lightning-Link® labeling technology enables the direct labeling of antibodies or proteins.

Simply pipette your antibody or biomolecule of choice into the vial of a lyophilized mixture containing the label of interest and incubate for around 3 hours. Please see the ab102887 protocol booklet for more details.

Learn more about our Lightning-Link® conjugation kits here

Key facts

Product details

Glucose Oxidase Conjugation Kit / Glucose Oxidase Labeling Kit ab102887 uses a simple and quick process for glucose oxidase labeling / conjugation of antibodies. It can also be used to conjugate other proteins or peptides. Learn about our . To conjugate an antibody to Glucose Oxidase using this kit: - add modifier to antibody and incubate for 3 hrs - add quencher and incubate for 30 mins The glucose oxidase conjugated antibody can be used immediately in WB, ELISA, IHC etc. No further purification is required and 100% of the antibody is recovered for use. Learn about buffer compatibility below; for incompatible buffers and low antibody concentrations, use our rapid . Use the  to learn more about the technology, or about conjugating other proteins and peptides to Glucose Oxidase. Custom size conjugation kits up to 100 mg are available on demand. Please contact us to discuss your requirements.

This product is manufactured by Expedeon, an Abcam company, and was previously called Lightning-Link® GOx Labeling Kit. 706-0015 is the same as the 1 mg size. 706-0010 is the same as the 3 x 100 ug size. 706-0030 is the same as the 3 x 10 ug size.

Amount and volume of antibody for conjugation to Glucose Oxidase

Kit size Recommended maximum
amount of antibody
Maximum antibody
volume1
3 x 10 μg 3 x 10 μg 3 x 10 μL
3 x 100 μg 3 x 100 μg 3 x 100 μL
1 mg 1 x 1 mg 1 x 1 mL

1 Ideal antibody concentration is 1mg/ml. 0.5 - 1 mg/ml can be used if the maximum antibody volume is not exceeded. Antibodies > 1 mg/ml or < 0.5 mg/ml should be diluted /concentrated.

Buffer Requirements for Conjugation

Buffer should be pH 6.5-8.5.

Compatible buffer constituents
If a concentration is shown, then the constituent should be no more than the concentration shown. If several constituents are close to the limit of acceptable concentration, then this can inhibit conjugation.

50mM / 0.6% Tris1 0.1% BSA 50% glycerol
0.1% sodium azide PBS Potassium phosphate
Sodium chloride HEPES Sucrose
Sodium citrate EDTA Trehalose

1 Tris buffered saline is almost always ≤ 50 mM / 0.6%

Incompatible buffer constituents

Thiomerosal Proclin Glycine
Arginine Glutathione DTT

If a constituent of the buffer containing your antibody or protein is not listed above, please contact us.

Only purified antibodies are suitable for use, ie. where other proteins, peptides, or amino acids are not present: antibodies in ascites fluid, serum or hybridoma culture.

Storing and handling conjugation kits

Lyophilized Lightning-Link® components are hygroscopic.

Kits are intentionally shipped at ambient temperature with silica gel to avoid exposure to moisture. Upon receipt, store the kit frozen and protect from moisture. Before opening the outer container, allow the lyophilized components to reach room temperature to minimize condensation.

What's included?

{ "values": { "3x10g": { "sellingSize": "3 x 10 µg", "publicAssetCode":"ab102887-3x10ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB102887-CMP01" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB102887-CMP02" }, { "size":"3 x 10 µg", "name":"GOx mix", "number":"AB102887-CMP03" } ] }, "3x100g": { "sellingSize": "3 x 100 µg", "publicAssetCode":"ab102887-3x100ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB102887-CMP01" }, { "size":"3 x 100 µg", "name":"GOx mix", "number":"AB102887-CMP03" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB102887-CMP02" } ] }, "1mg": { "sellingSize": "1 mg", "publicAssetCode":"ab102887-1mg", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB102887-CMP01", "productcode":"" }, { "size":"1 x 1 mg", "name":"GOx mix", "number":"AB102887-CMP03", "productcode":"" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB102887-CMP02", "productcode":"" } ] } } }

Properties and storage information

Shipped at conditions
Ambient - Cannot Ship with Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Product protocols

Target data

Publications (9)

Recent publications for all applications. Explore the full list and refine your search

Biosensors 12: PubMed35323432

2022

Magnetic Immunosensor Coupled to Enzymatic Signal for Determination of Genomic DNA Methylation.

Applications

Unspecified application

Species

Unspecified reactive species

Yitao Liang,Bin Zhang,Zexin Xue,Xuesong Ye,Bo Liang

Sensors (Basel, Switzerland) 21: PubMed33670868

2021

Paper-Based Competitive Immunochromatography Coupled with an Enzyme-Modified Electrode to Enable the Wireless Monitoring and Electrochemical Sensing of Cotinine in Urine.

Applications

Unspecified application

Species

Unspecified reactive species

Nutcha Larpant,Pramod K Kalambate,Tautgirdas Ruzgas,Wanida Laiwattanapaisal

Biosensors & bioelectronics 148:111824 PubMed31698303

2019

Impact of assay format on miRNA sensing: Electrochemical microfluidic biosensor for miRNA-197 detection.

Applications

Unspecified application

Species

Unspecified reactive species

Hazal Kutluk,Richard Bruch,Gerald A Urban,Can Dincer

Advanced materials (Deerfield Beach, Fla.) 31:e1905311 PubMed31663165

2019

CRISPR/Cas13a-Powered Electrochemical Microfluidic Biosensor for Nucleic Acid Amplification-Free miRNA Diagnostics.

Applications

Unspecified application

Species

Unspecified reactive species

Richard Bruch,Julia Baaske,Claire Chatelle,Mailin Meirich,Sibylle Madlener,Wilfried Weber,Can Dincer,Gerald Anton Urban

Biosensors & bioelectronics 126:102-107 PubMed30396016

2018

A bisulfite treatment and PCR-free global DNA methylation detection method using electrochemical enzymatic signal engagement.

Applications

Unspecified application

Species

Unspecified reactive species

Ripon Bhattacharjee,Sofia Moriam,Nam-Trung Nguyen,Muhammad J A Shiddiky

Biosensors & bioelectronics 126:82-87 PubMed30396021

2018

Calorimetric sandwich-type immunosensor for quantification of TNF-α.

Applications

Unspecified application

Species

Unspecified reactive species

Saif Mohammad Ishraq Bari,Louis G Reis,Gergana G Nestorova

Proceedings of the National Academy of Sciences of 113:6403-8 PubMed27217569

2016

Enzymatically enhanced collisions on ultramicroelectrodes for specific and rapid detection of individual viruses.

Applications

Unspecified application

Species

Unspecified reactive species

Jeffrey E Dick,Adam T Hilterbrand,Lauren M Strawsine,Jason W Upton,Allen J Bard

Talanta 148:200-8 PubMed26653441

2015

Rapid detection of Escherichia coli O157:H7 and Salmonella Typhimurium in foods using an electrochemical immunosensor based on screen-printed interdigitated microelectrode and immunomagnetic separation.

Applications

Unspecified application

Species

Unspecified reactive species

Meng Xu,Ronghui Wang,Yanbin Li

Analytical chemistry 85:4863-8 PubMed23663141

2013

Glucose-oxidase label-based redox cycling for an incubation period-free electrochemical immunosensor.

Applications

Unspecified application

Species

Unspecified reactive species

Amardeep Singh,Seonhwa Park,Haesik Yang
View all publications
websiteProtocolBooklet
en
websiteProtocolBooklet
zh

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com