JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB269900

PE/Atto 594 Conjugation Kit - Lightning-Link®

Be the first to review this product! Submit a review

|

(4 Publications)

PE/Atto 594 Conjugation Kit - Lightning-Link® (ab269900) offers several standout features:

- Rapid Conjugation: achieve PE/Atto 594 labeling in under 4 hours with just 30 seconds of hands-on time.
- High Efficiency: ensures 100% antibody recovery, meaning no loss of valuable antibodies.
- Versatility: suitable for conjugating antibodies, proteins, and peptides. PE/Atto 594 labeled antibodies can be used immediately in applications such as Flow cytometry, ELISA, and Immunohistochemistry (IHC) without further purification.
1 Images
Schematic Diagram - PE/Atto 594 Conjugation Kit - Lightning-Link® (AB269900)
  • Schematic Diagram

Supplier Data

This illustration demonstrates a general procedure of how Lightning-Link® labeling technology enables the direct labeling of antibodies or proteins.

Simply pipette your antibody or biomolecule of choice into the vial of a lyophilized mixture containing the label of interest and incubate for around 3 hours. Please see the ab269900 protocol booklet for more details.

Learn more about our Lightning-Link® conjugation kits here

Key facts

Product details

PE/Atto 594 Conjugation Kit - Lightning-Link® (ab269900) uses a simple and quick process for PE/Atto 594 labeling / conjugation of antibodies. It can also be used to conjugate other proteins or peptides.

To conjugate an antibody to PE/Atto 594 using this kit:
- add modifier to antibody and incubate for 15 mins
- add quencher and incubate for 5 mins

The PE/Atto 594 conjugated antibody can be used immediately in Flow cytometry and other applications. No further purification is required and 100% of the antibody is recovered for use.

Learn about our antibody labeling kits and their advantages here.

Learn about buffer compatibility below; for incompatible buffers and low antibody concentrations, use our antibody purification and concentration kits.
Custom size conjugation kits up to 100 mg are available on demand. Please contact us to discuss your requirements.

Amount and volume of antibody for conjugation to PE/Atto 594

Kit size Recommended
amount of antibody1
Maximum
amount of antibody
Maximum antibody
volume2
3 x 10 µg 3 x 10µg 3 x 10 µg 3 x 10 µL
60 µg 60 µg 60 µg 60 µL
3 x 60 µg 3 x 60 µg 3 x 60 µg 3 x 60 µL
600 µg 0.6 mg 0.6 mg 0.6 mL

1 Using the maximum amount of antibody may result in less labeling per antibody.

2 Ideal antibody concentration is 1mg/mL. 0.5 - 1 mg/mL can be used if the maximum antibody volume is not exceeded. Antibodies > 1 mg/mL or < 0.5 mg/mL should be diluted /concentrated.

Buffer Requirements for Conjugation

Buffer should be pH 6.5-8.5.

Compatible buffer constituents
If a concentration is shown, then the constituent should be no more than the concentration shown. If several constituents are close to the limit of acceptable concentration, then this can inhibit conjugation.

50mM / 0.6% Tris1 0.1% BSA2 50% glycerol
0.1% sodium azide PBS Potassium phosphate
Sodium chloride HEPES Sucrose
Sodium citrate EDTA Trehalose

1 Tris buffered saline is almost always ≤ 50 mM / 0.6%
2 BSA can also interfere with the use of the conjugated antibody in tissue staining.

Incompatible buffer constituents

Thiomerosal Proclin Glycine
Arginine Glutathione DTT

If a constituent of the buffer containing your antibody or protein is not listed above, please contact us.

Only purified antibodies are suitable for use, ie. where other proteins, peptides, or amino acids are not present: antibodies in ascites fluid, serum or hybridoma culture media are incompatible.

Storing and handling conjugation kits

Lyophilized Lightning-Link® components are hygroscopic.

Kits are intentionally shipped at ambient temperature with silica gel to avoid exposure to moisture. Upon receipt, store the kit frozen and protect from moisture. Before opening the outer container, allow the lyophilized components to reach room temperature to minimize condensation.

This product is manufactured by Expedeon, an Abcam company, and was previously called Lightning-Link® R-PE/Atto 594 Labeling Kit. 768-0015 is the same as the 600 µg size. 768-0010 is the same as the 3 x 60 µg size. 768-0030 is the same as the 3 x 10 µg size. 768-0005 is the same as the 60 µg size.

What's included?

{ "values": { "60g": { "sellingSize": "60 µg", "publicAssetCode":"ab269900-60ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269900-CMP02" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269900-CMP03" }, { "size":"1 x 60 µg", "name":"PE/Atto 594 mix (Lyophilized)", "number":"AB269900-CMP01" } ] }, "600g": { "sellingSize": "600 µg", "publicAssetCode":"ab269900-600ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269900-CMP02" }, { "size":"1 x 600 µg", "name":"PE/Atto 594 mix (Lyophilized)", "number":"AB269900-CMP01" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269900-CMP03" } ] }, "3x60g": { "sellingSize": "3 x 60 µg", "publicAssetCode":"ab269900-3x60ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269900-CMP02" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269900-CMP03" }, { "size":"3 x 60 µg", "name":"PE/Atto 594 mix (Lyophilized)", "number":"AB269900-CMP01" } ] }, "3x10g": { "sellingSize": "3 x 10 µg", "publicAssetCode":"ab269900-3x10ug", "assetComponentDetails": [ { "size":"1 x 200 µL", "name":"Quencher reagent", "number":"AB269900-CMP02", "productcode":"" }, { "size":"3 x 10 µg", "name":"PE/Atto 594 mix (Lyophilized)", "number":"AB269900-CMP01", "productcode":"" }, { "size":"1 x 200 µL", "name":"Modifier reagent", "number":"AB269900-CMP03", "productcode":"" } ] } } }

Properties and storage information

Shipped at conditions
Ambient - Cannot Ship with Ice
Appropriate short-term storage conditions
-20°C
Appropriate long-term storage conditions
-20°C
Storage information
-20°C

Product protocols

Target data

Publications (4)

Recent publications for all applications. Explore the full list and refine your search

iScience 24:103312 PubMed34765928

2021

Reduced mitochondrial respiration in T cells of patients with major depressive disorder.

Applications

Unspecified application

Species

Unspecified reactive species

Stefanie Gamradt,Helge Hasselmann,Aline Taenzer,Jelena Brasanac,Victoria Stiglbauer,Arne Sattler,Max Sajitz-Hermstein,Sylwia Kierszniowska,Caren Ramien,Jan Nowacki,Lea Mascarell-Maricic,Katja Wingenfeld,Dominique Piber,Andreas Ströhle,Katja Kotsch,Friedemann Paul,Christian Otte,Stefan M Gold

iScience 24:103312 PubMed34765928

2021

Reduced mitochondrial respiration in T cells of patients with major depressive disorder.

Applications

Unspecified application

Species

Unspecified reactive species

Stefanie Gamradt,Helge Hasselmann,Aline Taenzer,Jelena Brasanac,Victoria Stiglbauer,Arne Sattler,Max Sajitz-Hermstein,Sylwia Kierszniowska,Caren Ramien,Jan Nowacki,Lea Mascarell-Maricic,Katja Wingenfeld,Dominique Piber,Andreas Ströhle,Katja Kotsch,Friedemann Paul,Christian Otte,Stefan M Gold

The EMBO journal 40:e108249 PubMed34296442

2021

SARS-CoV-2 nucleocapsid suppresses host pyroptosis by blocking Gasdermin D cleavage.

Applications

Unspecified application

Species

Unspecified reactive species

Juan Ma,Fangrui Zhu,Min Zhao,Fei Shao,Dou Yu,Jiangwen Ma,Xusheng Zhang,Weitao Li,Yan Qian,Yan Zhang,Dong Jiang,Shuo Wang,Pengyan Xia

Methods in molecular biology (Clifton, N.J.) 1389:187-94 PubMed27460246

2016

Using Image-Based Flow Cytometry to Assess Monocyte Oxidized LDL Phagocytosis Capacity.

Applications

Unspecified application

Species

Unspecified reactive species

Andrea L Henning,Adam S Venable,Eric A Prado,Brian K McFarlin
View all publications
websiteProtocolBooklet
en
websiteProtocolBooklet
zh

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com