Human C8a (Complement C8a) ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human C8a (Complement C8a) ELISA Kit is a single-wash 90-min Simplestep used to quantify Human C8a (Complement C8a) with a sensitivity of 40.141 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
Complement component C8 alpha chain, Complement component 8 subunit alpha, C8A
- sELISA
Supplier Data
Sandwich ELISA - Human C8a (Complement C8a) ELISA Kit (AB288173)
Interpolated concentrations of C8a in normal human serum donors.
Serum of ten individual healthy human male donors was measured in duplicate. Interpolated dilution factor corrected values are plotted (mean +- SD, n=2). The mean C8a concentration was determined to be 55.3 ug/mL with a range of 38.35 - 73.45 ug/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human C8a (Complement C8a) ELISA Kit (AB288173)
Interpolated concentrations of human C8a in serum, plasma (EDTA), plasma (citrate), and plasma (heparin). Interpolated concentration of native C8a was measured in duplicate at different sample concentrations. Undiluted samples are as follows : serum 1 : 8,000, plasma (EDTA)1 : 8,000, plasma (citrate)1 : 8,000, and plasma (heparin)1 : 4,000. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.
- sELISA
Supplier Data
Sandwich ELISA - Human C8a (Complement C8a) ELISA Kit (AB288173)
Interpolated concentrations of human C8a in milk and saliva. Interpolated concentration of native C8a was measured in duplicate at different sample concentrations. Undiluted samples are as follows : milk 5% and saliva 10%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.
- sELISA
Supplier Data
Sandwich ELISA - Human C8a (Complement C8a) ELISA Kit (AB288173)
Example of human C8a standard curve in Sample Diluent NS. Example of human C8a standard curve. Background-subtracted data values (mean +/- SD) are graphed.
Reactivity data
Product details
Human C8a (Complement C8a) ELISA Kit (ab288172) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of Human Complement C8a protein in cell culture supernatant, plasma, milk, saliva and serum samples. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human Complement C8a with 40.141 pg/mL sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
-Single-wash protocol reduces assay time to 90 minutes or less
-High sensitivity, specificity and reproducibility from superior antibodies
-Fully validated in biological samples
-96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Supplementary information
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
The C8a chain works in concert with C8 beta and C8 gamma to form the C8 complex of the complement system. This protein becomes part of the larger MAC a lytic complex that facilitates cell membrane disruptions thereby initiating cell lysis. The membrane attack complex plays a defensive role against pathogenic microorganisms contributing to innate immunity.
Pathways
The complement system involving C8a plays a central role in the innate immune pathway and the alternative pathway of complement activation. These pathways are essential for the protection against infections. The C5 convertase acts upstream of C8a cleaving C5 to C5b which then associates with C6 and C7 allowing C8a and its counterparts C8b and C8g to bind and initiate MAC formation. C9 is the final protein to bind completing the complex and resulting in the lysis of the target.
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com