Human CD163 ELISA Kit, Chemiluminescent is a 55-min single-wash SimpleStep Ignite™ ELISA for the rapid quantification of Human CD163 with higher sensitivity and broader measuring range.
- Single 30 min incubation and single-wash step for results in less than an hour.
- Chemiluminescent detection allows a broad dynamic range: 43.9 - 32000 pg/ml with a sensitivity of 16 pg/mL.
- Design your own immunoassay: we also offer the conjugation-ready antibody pair.
- Patent pending
View Alternative Names
CD163, M130, Scavenger receptor cysteine-rich type 1 protein M130, Hemoglobin scavenger receptor
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
Interpolated concentrations of native CD163 in stimulated human PBMC cell culture supernatant samples. PBMC samples were stimulated for 46 hours with 1.5% PHA-M. The concentrations of CD163 were measured in duplicates, interpolated from the CD163 standard curves and corrected for sample dilution. Undiluted samples are as follows : stimulated PBMC supernatant 25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CD163 concentration was determined to be 22 ng/mL in stimulated PBMC supernatant.
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
Dynamic range comparison between the Chemiluminescent Human CD163 SimpleStep ELISA, colorimetric Human CD163 SimpleStep ELISA (ab274394), and leading colorimetric competitor. The Chemiluminescent SimpleStep ELISA kit shows increased sensitivity and dynamic range.
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
Standard curve comparison between the Chemiluminescent Human CD163 SimpleStep ELISA and colorimetric Human CD163 SimpleStep ELISA (ab274394) in Sample Diluent 25BS. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
Interpolated concentrations of native CD163 in human serum and plasma samples. The concentrations of CD163 were measured in duplicates, interpolated from the CD163 standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 1%, plasma (citrate) 1%, plasma (heparin) 1%, and plasma (EDTA) 1%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CD163 concentration was determined to be 704 ng/mL in serum, 552 ng/mL in plasma (citrate), 545 ng/ml in plasma (heparin), and 515 ng/mL in plasma (EDTA).
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
Serum from ten individual healthy human female donors was measured in duplicate. Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CD163 concentration was determined to be 563 ng/mL with a range of 338 – 1,030 ng/mL.
- sELISA
Lab
Sandwich ELISA - Human CD163 ELISA Kit, Chemiluminescent (AB325896)
SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
Reactivity data
Product details
How the assay works
Human CD163 ELISA Kit, Chemiluminescent (ab325896) SimpleStep Ignite™ ELISA employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep Ignite™ ELISA kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human CD163 (ab325896) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-CD163 antibody [EPR22675-13] - BSA and Aside free (Capture) ab274440
- Anti-CD163 antibody [EPR22675-102] - BSA and Aside free (Detector) ab274441
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com