Human Fibrinogen ELISA Kit, Chemiluminescent
- SimpleStep Ignite™ ELISA
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human Fibrinogen ELISA Kit, Chemiluminescent is a 55-min single-wash SimpleStep Ignite™ ELISA for the rapid quantification of Human Fibrinogen with higher sensitivity and broader measuring range.
- Single 30 min incubation and single-wash step for results in less than an hour.
- Chemiluminescent detection allows a broad dynamic range: 82.3 - 60000 pg/ml with a sensitivity of 40.37pg/mL.
- Design your own immunoassay: we also offer the conjugation-ready antibody pair.
-Patent pending
View Alternative Names
Fibrinogen alpha chain, FGA
- sELISA
Lab
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
- sELISA
Lab
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Standard curve comparison between the Chemiluminescent Human Fibrinogen SimpleStep ELISA and colorimetric Human Fibrinogen SimpleStep ELISA (ab241383) in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Dynamic range comparison between the Chemiluminescent Human Fibrinogen SimpleStep ELISA, colorimetric Human Fibrinogen SimpleStep ELISA (ab241383), and leading chemiluminescent competitor. The Chemiluminescent SimpleStep ELISA kit shows increased sensitivity and increased dynamic range.
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Percent reactivity against related fibrinogen proteins.
The following recombinant/native proteins were prepared at 50 ng/mL and assayed for cross-reactivity. Percent reactivity is determined by interpolating the protein concentrations from the standard curve and expressing the interpolated concentrations as a percentage of the protein concentration assayed at the same concentration.
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Serum from ten individual healthy human female donors was measured in duplicate.
Interpolated dilution factor corrected values are plotted (mean +/- SD n=2). The mean Fibrinogen concentration was determined to be 1070 ng/mL with a range of 647 – 2027 ng/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Interpolated concentrations of native Fibrinogen in human serum and plasma samples.
The concentrations of Fibrinogen were measured in duplicates interpolated from the Fibrinogen standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 1 : 670 plasma (citrate) 1 : 5x105 plasma (EDTA) 1 : 5x105 and plasma (heparin) 1 : 5x105. The interpolated dilution factor corrected values are plotted (mean +/- SD n=2). The mean Fibrinogen concentration was determined to be 3.45 µg/mL in serum 2.86 mg/mL in plasma (citrate) 2.96 mg/mL in plasma (EDTA) and 2.64 mg/mL in plasma (heparin).
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Interpolated concentrations of native Fibrinogen in human urine saliva milk and cell culture supernatant samples.
The concentrations of Fibrinogen were measured in duplicates interpolated from the Fibrinogen standard curves and corrected for sample dilution. Undiluted samples are as follows : urine 1 : 1.7 saliva 1 : 133 milk 1 : 133 and HepG2 supernatant 1 : 500. The interpolated dilution factor corrected values are plotted (mean +/- SD n=2). The mean Fibrinogen concentration was determined to be 5.93 ng/mL in urine 934.5 ng/mL in saliva 199.7 ng/mL in milk and 1.35 µg/mL in HepG2 supernatant.
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Linearity of dilution is determined based on interpolated values from the standard curve. Linearity of dilution defines a sample concentration interval in which interpolated target concentrations are directly proportional to sample dilution.
Native Fibrinogen was measured in the following biological samples in a 2-fold dilution series. Sample dilutions are made in Sample Diluent NS.
- sELISA
Supplier Data
Sandwich ELISA - Human Fibrinogen ELISA Kit, Chemiluminescent (AB326383)
Linearity of dilution is determined based on interpolated values from the standard curve. Linearity of dilution defines a sample concentration interval in which interpolated target concentrations are directly proportional to sample dilution.
Native Fibrinogen was measured in the following biological samples in a 2-fold dilution series. Sample dilutions are made in Sample Diluent NS.
Reactivity data
Product details
How the assay works
Human Fibrinogen ELISA Kit, Chemiluminescent (ab326383) SimpleStep Ignite™ ELISA employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep Ignite™ ELISA kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human Fibrinogen (ab326383) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-Fibrinogen antibody [EPR19765-189] - BSA and Azide free (Capture) ab244636
- Anti-Fibrinogen antibody [EPR19765-63] - BSA and Azide free (Detector) ab244897
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com