Human Heme Oxygenase 1 ELISA Kit, Fluorescent
- CatchPoint SimpleStep ELISA
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human Heme Oxygenase 1 ELISA Kit, Fluorescent is a single-wash 90-min Simplestep used to quantify Human Heme Oxygenase 1 with a sensitivity of 3.5 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Fluorescent Sandwich ELISA - 530/570/590 nm readout : works on any standard plate reader
View Alternative Names
HO, HO1, HMOX1, Heme oxygenase 1, HO-1
- ELISA
Supplier Data
ELISA - Human Heme Oxygenase 1 ELISA Kit, Fluorescent (AB229429)
- sELISA
Supplier Data
Sandwich ELISA - Human Heme Oxygenase 1 ELISA Kit, Fluorescent (AB229429)
Serum from ten individual healthy human male donors was measured in duplicate.
Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Heme Oxygenase 1 concentration was determined to be 1,630 pg/mL with a range of 391 – 3,198 pg/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human Heme Oxygenase 1 ELISA Kit, Fluorescent (AB229429)
Example of human Heme Oxygenase 1 (HO 1) standard curve in Sample Diluent NS.
Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Human Heme Oxygenase 1 ELISA Kit, Fluorescent (AB229429)
Interpolated concentrations of native Heme Oxygenase 1 in human liver homogenate extract and A549 cell extract based on a 15.6 μg/mL liver homogenate extract and 5 μg/mL A549 cell extract load. The concentrations of Heme Oxygenase 1 were measured in duplicate and interpolated from the Heme Oxygenase 1 standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Heme Oxygenase 1 concentration was determined to be 3.30 ng/mL in liver homogenate extract and 1.60 ng/mL in A549 cell extract.
- sELISA
Supplier Data
Sandwich ELISA - Human Heme Oxygenase 1 ELISA Kit, Fluorescent (AB229429)
Interpolated concentrations of native Heme Oxygenase 1 in human serum and plasma (EDTA) samples.
The concentrations of Heme Oxygenase 1 were measured in duplicate, interpolated from the Heme Oxygenase 1 standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 50%, plasma (EDTA) 25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Heme Oxygenase 1 concentration was determined to be 1.37 ng/mL in serum and 2.12 ng/mL in plasma (EDTA).
Reactivity data
Product details
Human Heme Oxygenase 1 ELISA Kit, Fluorescent ab229429 is a rapid single-wash 90-min sandwich ELISA to measure Human Heme Oxygenase 1 in serum, heparin plasma, citrate plasma, EDTA plasma, cell culture extracts, culture extracts. This CatchPoint SimpleStep sensitivity is 3.5 pg/mL.
How the assay works
Human Heme Oxygenase 1 CatchPoint SimpleStep ELISA employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. CatchPoint HRP Development Solution containing the Stoplight Red Substrate is added. During incubation, the substrate is catalyzed by HRP generating a fluorescent product. Signal is generated proportionally to the amount of bound analyte and the intensity is measured in a fluorescence plater reader at 530/570/590 nm Excitation/Cutoff/Emission. This kit is optimised for Molecular Devices Readers: If using a Molecular Devices' plate reader supported by SoftMax® Pro software, a preconfigured protocol for these CatchPoint SimpleStep ELISA Kits is available with all the protocol and analysis settings at www.softmaxpro.org.
Assay Specificity
Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human Heme Oxygenase 1 ELISA Kit, Fluorescent ab229429 protocol summary
1. Mix: add samples/standards to the wells together with the capture and detector antibody cocktail. Incubate 1 hr at room temperature
2. Wash
3. Add TMB development solution - incubate for 10 min
4. Add Stop solution
5. Read the results on a fluorescent plate reader at 530/570/590 nm Excitation/Cutoff/Emission.
Colorimetric version
This kit is also available with a colorimetric readout as Human Heme Oxygenase 1 ELISA Kit ab207621.
Both the fluroescent and colorimetric version share the same antibody pair and protein standard.
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation
- Anti-Heme Oxygenase 1 antibody [EPR18689-5] - BSA and Azide free (Capture) ab242951
- Anti-Heme Oxygenase 1 antibody [EPR18689-126] - BSA and Azide free (Detector) ab242982
Heme oxygenase 1 is an enzyme that functions in heme catabolism. The activity of heme oxygenase 1 is to cleave the heme ring to form biliverdin. There are two isozymes of heme oxygenase that have 56% amino acid sequence identity: inducible heme oxygenase 1 and constitutively expressed heme oxygenase 2.
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Supplementary information
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
Heme Oxygenase 1 serves important protective functions in the body. It is not part of a larger complex but its products such as carbon monoxide and biliverdin have their own biological activities. Carbon monoxide produced by HO-1 has antiflammatory properties and can modulate apoptotic pathways. Biliverdin is reduced to bilirubin which acts as an antioxidant. The enzyme therefore directly influences cellular stress responses and maintains cellular homeostasis through these processes.
Pathways
Heme Oxygenase 1 is integrally involved in oxidative stress response and heme metabolism. It participates in the cellular response to oxidative damage by reducing oxidative stress and promoting cytoprotection. Through its heme degradation activity it is connected with the synthesis of biologically active molecules like bilirubin and carbon monoxide. Heme Oxygenase 1 activity is related to other proteins in oxidative stress pathways such as Nuclear Factor Erythroid 2-Related Factor 2 (Nrf2) which regulates its expression and globins which are sources of heme for HO-1 activity.
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com