Human IL-1 beta ELISA Kit, Chemiluminescent
- Recombinant
- SimpleStep Ignite™ ELISA
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human IL-1 beta ELISA Kit, Chemiluminescent is a 55-min single-wash SimpleStep Ignite™ ELISA for the rapid quantification of Human IL-1 beta with higher sensitivity and broader measuring range.
- Single 30 min incubation and single-wash step for results in less than an hour.
- Chemiluminescent detection allows a broad dynamic range: 5.49 - 4000 pg/ml with a sensitivity of 3.95 pg/mL.
- Design your own immunoassay: we also offer the conjugation-ready antibody pair.
- Patent pending
View Alternative Names
IL1F2, IL1B, Interleukin-1 beta, IL-1 beta, Catabolin
- sELISA
Lab
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
- sELISA
Lab
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
Standard curve comparison between the Chemiluminescent Human IL-1 beta SimpleStep ELISA and colorimetric Human IL-1 beta SimpleStep ELISA (ab214025) in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
THP-1 cells were cultured unstimulated or stimulated with 5 µg/mL Lipopolysaccharide (LPS). Conditioned media was harvested after 48 hours. IL-1 beta was measured in 100% unstimulated and LPS stimulated THP-1 supernatant. The concentrations of IL-1 beta were measured in duplicate and interpolated from the IL-1 beta standard curves. The interpolated values are plotted (mean +/- SD, n=2). The mean IL-1 beta concentration was determined to be 718 pg/mL in LPS stimulated THP-1 supernatant. There was no detectable signal in unstimulated supernatant.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
Human peripheral blood mononuclear cells were cultured unstimulated or stimulated with 10 µg/mL PHA. Conditioned media was harvested after 48 hours. IL-1 beta was measured in 50% unstimulated and PHA stimulated PBMC supernatant. The concentrations of IL-1 beta were measured in duplicate, interpolated from the IL-1 beta standard curves and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-1 beta concentration was determined to be 1,273 pg/mL in PHA stimulated PBMC supernatant. There was no detectable signal in unstimulated supernatant.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
Serum from ten individual healthy human male donors was measured in duplicate. Interpolated values are plotted (mean +/- SD, n=2). IL-1 beta was measured in 2 donor serum samples (30 pg/mL and 140 pg/mL) and the remaining 8 samples measured less than the lowest point of the IL-1 beta standard curve.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-1 beta ELISA Kit, Chemiluminescent (AB325901)
Interpolated concentrations of native IL-1 beta in human PHA stimulated PBMC supernatant and LPS stimulated THP-1 supernatant samples. The concentrations of IL-1 beta were measured in duplicates, interpolated from the IL-1 beta standard curves and corrected for sample dilution. Undiluted samples are as follows : PBMC supernatant 50% and 100% THP-1 supernatant. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-1 beta concentration was determined to be 1,301 pg/mL in PBMC supernatant and 734 pg/mL in THP-1 supernatant.
Reactivity data
Product details
How the assay works
Human IL-1 beta ELISA Kit, Chemiluminescent (ab325901) SimpleStep Ignite™ ELISA employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep Ignite™ ELISA kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human IL-1 beta (ab325901) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-IL-1 beta antibody [EPR18815-27] BSA and Azide free (Capture) ab242561
- Anti-IL-1 beta antibody [EPR18815-128] BSA and Azide free (Detector) ab242986
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com