Human IL-10 ELISA Kit, Fluorescent is a single-wash 90-min Simplestep used to quantify Human IL-10 with a sensitivity of 2.1 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Fluorescent Sandwich ELISA - 530/570/590 nm readout : works on any standard plate reader
Application | Reactivity | Dilution info | Notes |
---|---|---|---|
Application sELISA | Reactivity Reacts | Dilution info - | Notes - |
Select an associated product type
Major immune regulatory cytokine that acts on many cells of the immune system where it has profound anti-inflammatory functions, limiting excessive tissue disruption caused by inflammation. Mechanistically, IL10 binds to its heterotetrameric receptor comprising IL10RA and IL10RB leading to JAK1 and STAT2-mediated phosphorylation of STAT3 (PubMed:16982608). In turn, STAT3 translocates to the nucleus where it drives expression of anti-inflammatory mediators (PubMed:18025162). Targets antigen-presenting cells (APCs) such as macrophages and monocytes and inhibits their release of pro-inflammatory cytokines including granulocyte-macrophage colony-stimulating factor /GM-CSF, granulocyte colony-stimulating factor/G-CSF, IL-1 alpha, IL-1 beta, IL-6, IL-8 and TNF-alpha (PubMed:11564774, PubMed:1940799, PubMed:7512027). Interferes also with antigen presentation by reducing the expression of MHC-class II and co-stimulatory molecules, thereby inhibiting their ability to induce T cell activation (PubMed:8144879). In addition, controls the inflammatory response of macrophages by reprogramming essential metabolic pathways including mTOR signaling (By similarity).
Interleukin-10, IL-10, Cytokine synthesis inhibitory factor, CSIF, IL10
Human IL-10 ELISA Kit, Fluorescent is a single-wash 90-min Simplestep used to quantify Human IL-10 with a sensitivity of 2.1 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Fluorescent Sandwich ELISA - 530/570/590 nm readout : works on any standard plate reader
Sample | n | C.V. |
---|---|---|
Sample Supernatant | n 5 | C.V. 5.2 |
Sample | n | C.V. |
---|---|---|
Sample Supernatant | n 3 | C.V. 3.2 |
Sample type | Average % | Range |
---|---|---|
Sample type Cell culture supernatant | Average % = 108 | Range 105 - 111 % |
Sample type Serum | Average % = 109 | Range 108 - 112 % |
Sample type EDTA Plasma | Average % = 109 | Range 103 - 118 % |
Sample type Heparin Plasma | Average % = 116 | Range 113 - 117 % |
Sample type Citrate plasma | Average % = 111 | Range 105 - 119 % |
Sample type Cell culture media | Average % = 106 | Range 102 - 111 % |
IL-10 in vitro CatchPoint SimpleStep ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of IL-10 protein in human serum, plasma, and cell culture supernatant samples
The CatchPoint SimpleStep ELISA employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. CatchPoint HRP Development Solution containing the Stoplight Red Substrate is added. During incubation, the substrate is catalyzed by HRP generating a fluorescent product. Signal is generated proportionally to the amount of bound analyte and the intensity is measured in a fluorescence plater reader at 530/570/590 nm Excitation/Cutoff/Emission.
Interleukin 10 (IL-10) is a cytokine involved in immunoregulation through the promotion of Th2 response and inhibition of Th1 responses. It is produced by cells of hematopoietic origin, keratinocytes, placental cytotrophoblasts, and hepatic stellate cells.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Human IL-10 Standard Curve Comparison.
Standard Curve comparison between human IL-10 current (new) SimpleStep ELISA kit and original ELISA kit. The current SimpleStep ELISA kit shows increased sensitivity.
Interpolated concentrations of native IL-10 in human PBMC cell culture supernatant samples.
The concentrations of IL-10 were measured in duplicates, interpolated from the IL-10 standard curves and corrected for sample dilution. Undiluted samples are as follows: stimulated PBMC cell culture supernatant 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-10 concentration was determined to be 462 pg/ml in stimulated PBMC cell culture supernatant. PBMC cell culture supernatant samples were stimulated for 46 hours with 1.5% PHA. Unstimulated PBMC cell culture supernatant samples were also measured; all values were below the detectable range of the assay.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com