Human IL-15RA ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human IL-15RA ELISA Kit is a single-wash 90-min Simplestep used to quantify Human IL-15RA with a sensitivity of 5.79 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Different formats for different needs: 384-well plate for higher throughput
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
CD215, Interleukin-15 receptor subunit alpha, IL-15 receptor subunit alpha, IL-15R-alpha, IL-15RA, IL15RA
- sELISA
Lab
Sandwich ELISA - Human IL-15RA ELISA Kit (AB264618)
Example of human IL-15RA standard curve in 96-well vs. 384-well plate. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-15RA ELISA Kit (AB264618)
Interpolated concentrations of native IL-15RA in human cell culture supernatant samples.
The concentrations of IL-15RA were measured in duplicates, interpolated from the IL-15RA standard curves and corrected for sample dilution. Undiluted samples are as follows : unstimulated PBMCs 50% and stimulated PBMCs 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-15RA concentration was determined to be undetectable in unstimulated PBMCs and 90.8 pg/mL in stimulated PBMCs.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-15RA ELISA Kit (AB264618)
Interpolated concentrations of native IL-15RA in human serum and plasma.
The concentrations of IL-15RA were measured in duplicates, interpolated from the IL-15RA standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 50% and plasma (citrate) 50%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-15RA concentration was determined to be 170.6 pg/mL in serum and 157.8 pg/mL in plasma (citrate).
- sELISA
Supplier Data
Sandwich ELISA - Human IL-15RA ELISA Kit (AB264618)
Representative image of Human IL-15RA ELISA Kit (ab264618)
Components shown from left to right :
- Sample diluent NS
- 10X Human IL-15RA Capture Antibody
- 10X Human IL-15RA Detector Antibody
- Human IL-15RA Lyophilised Purified Protein (2 vials)
- 50X Cell Extraction Enhancer Solution (ab193971)
- Stop Solution
- TMB solution
- 10X Wash Buffer PT (ab206977)
- Antibody Diluent 4BI
SimpleStep Pre-Coated 96-Well Microplate (ab206978) - shown behind bottles / vials.
Plate Seals - shown underneath bottles / vials.
Note : The vial labels shown in this image use generic names for illustrative purposes only and may not exactly match the specific component names included in the ELISA kit.
Note : Colors of solutions in image may not precisely match the shade of colors in the actual kit.
- sELISA
Supplier Data
Sandwich ELISA - Human IL-15RA ELISA Kit (AB264618)
Example of human IL-15RA standard curve in Sample Diluent NS + 1.5X Enhancer.
The IL-15RA standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
Reactivity data
Product details
Human IL-15RA ELISA Kit (ab264618) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of IL-15RA protein in cell culture supernatant, cit plasma, and serum. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human IL-15RA with 5.79 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
Interleukin-15 receptor subunit alpha is one of the three subunits that is part of its hematopoietin receptor family. IL-15RA contributes to IL-15 mediated effects such as cell survival, cell proliferation, and activation of T and B lymphocytes. This kit recognizes extracellular fragment of IL-15RA, which is solubilized and binds to IL-15 with high affinity. IL-15 does not interfere in ab264618.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com