Human MX1 ELISA Kit is a single-wash 90-min SimpleStep ELISA® for the quantitative measurement of Human MX1 in Cell Lysate, Tissue Extracts samples.
Application | Reactivity | Dilution info | Notes |
---|---|---|---|
Application sELISA | Reactivity Reacts | Dilution info - | Notes - |
Interferon-induced dynamin-like GTPase with antiviral activity against a wide range of RNA viruses and some DNA viruses. Its target viruses include negative-stranded RNA viruses and HBV through binding and inactivation of their ribonucleocapsid. May also antagonize reoviridae and asfarviridae replication. Inhibits thogoto virus (THOV) replication by preventing the nuclear import of viral nucleocapsids. Inhibits La Crosse virus (LACV) replication by sequestering viral nucleoprotein in perinuclear complexes, preventing genome amplification, budding, and egress. Inhibits influenza A virus (IAV) replication by decreasing or delaying NP synthesis and by blocking endocytic traffic of incoming virus particles. Enhances ER stress-mediated cell death after influenza virus infection. May regulate the calcium channel activity of TRPCs.
Interferon-induced GTP-binding protein Mx1, Interferon-induced protein p78, Interferon-regulated resistance GTP-binding protein MxA, Myxoma resistance protein 1, Myxovirus resistance protein 1, IFI-78K, MX1
Human MX1 ELISA Kit is a single-wash 90-min SimpleStep ELISA® for the quantitative measurement of Human MX1 in Cell Lysate, Tissue Extracts samples.
Sample | n | mean | SD | C.V. |
---|---|---|---|---|
Sample Extract | n 8 | mean - | SD - | C.V. 5.9 |
Sample | n | mean | SD | C.V. |
---|---|---|---|---|
Sample Extract | n 3 | mean - | SD - | C.V. 7.5 |
Sample type | Average % | Range |
---|---|---|
Sample type Cell Lysate | Average % = 93 | Range 84 - 99 % |
Sample type Tissue Extracts | Average % = 105 | Range 98 - 113 % |
Human MX1 SimpleStep ELISA® kit is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of MX1 protein in Cell Lysate, Tissue extracts. Quantitate Human MX1 with 14.15 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
-Single-wash protocol reduces assay time to 90 minutes or less
-High sensitivity, specificity and reproducibility from superior antibodies
-Fully validated in biological samples
-96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (Pre-coated 384 well Microplate SimpleStep ELISA® ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Interpolated concentration of native MX1 was measured in duplicate at different sample concentrations. Undiluted samples are as follows: 25 µg/mL Daudi + IFN alpha Extract, and 50 µg/mL tonsil tissue extract. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Cell Extraction Buffer PTR.
Daudi cells were treated overnight with 20 µg/mL human IFN-alpha then followed by protein extraction. Mock control Daudi cells accompanied cell treatment. Concentrations of human MX1 were measured in duplicate and interpolated against the standard curve. Results show the mean human MX1 was not detected (ND) in the mock samples compared to 2883 pg/mL in IFN-alpha treated samples.
Example of human MX1 standard curve. Background-subtracted data values (mean +/- SD) are graphed.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com