Human PAR1/Thrombin Receptor ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human PAR1/Thrombin Receptor ELISA Kit is a single-wash 90-min Simplestep used to quantify Human PAR1/Thrombin Receptor with a sensitivity of 1.21 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
CF2R, PAR1, TR, F2R, Proteinase-activated receptor 1, PAR-1, Coagulation factor II receptor, Thrombin receptor
- sELISA
Supplier Data
Sandwich ELISA - Human PAR1/Thrombin Receptor ELISA Kit (AB283544)
Interpolated concentrations of native PAR1/Thrombin Receptor in human HT-29 cell extract based on a 100 μg/mL extract load.
The concentrations of PAR1/Thrombin Receptor were measured in duplicate and interpolated from the PAR1/Thrombin Receptor standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean PAR1/Thrombin Receptor concentration was determined to be 236.37 pg/mL in HT-29 cell extract.
- sELISA
Supplier Data
Sandwich ELISA - Human PAR1/Thrombin Receptor ELISA Kit (AB283544)
Interpolated concentrations of native PAR1/Thrombin Receptor in human serum, plasma and cell culture supernatant samples.
The concentrations of PAR1/Thrombin Receptor were measured in duplicates, interpolated from the PAR1/Thrombin Receptor standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 50%, plasma (EDTA) 50%, plasma (heparin) 100%, HT-29 supernatant 50%, and A375 supernatant 100%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean PAR1/Thrombin Receptor concentration was determined to be 420.97 pg/mL in serum, 464.59 pg/mL in plasma (EDTA), 97.80 pg/mL in plasma (heparin), 360.01 pg/mL in HT-29 supernatant and 28.52 pg/mL in A375 supernatant.
- sELISA
Supplier Data
Sandwich ELISA - Human PAR1/Thrombin Receptor ELISA Kit (AB283544)
Example of human PAR1/Thrombin Receptor standard curve in Sample Diluent NS.
The PAR1/Thrombin Receptor standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
Reactivity data
Product details
Human PAR1/Thrombin Receptor ELISA kit (ab272199) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of Human PAR1/Thrombin Receptor protein in human serum, plasma, cell culture supernatant, and cell culture extract samples. It uses our proprietary SimpleStep ELISA® technology. Quantitate Human PAR1/Thrombin Receptor with 1.21 pg/mL sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
-Single-wash protocol reduces assay time to 90 minutes or less
-High sensitivity, specificity and reproducibility from superior antibodies
-Fully validated in biological samples
-96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
Human PAR1/Thrombin Receptor also known as Protease-activated receptor 1 or coagulation factor II (thrombin) receptor is a protein that in humans is encoded by the F2R gene. Human PAR1 is a G protein-coupled receptor and one of four protease-activated receptors involved in the regulation of thrombotic response. Highly expressed in platelets and endothelial cells, human PAR1 plays a key role in mediating the interplay between coagulation and inflammation, which is important in the pathogenesis of inflammatory and fibrotic lung diseases. Human PAR1 is also involved both in disruption and maintenance of endothelial barrier integrity, through interaction with either thrombin or activated protein C, respectively.
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com