Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent
- Recombinant
- SimpleStep Ignite™ ELISA
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent is a 55-min single-wash SimpleStep Ignite™ ELISA for the rapid quantification of Human Polymeric immunoglobulin receptor (PIGR) with higher sensitivity and broader measuring range.
- Single 30 min incubation and single-wash step for results in less than an hour.
- Chemiluminescent detection allows a broad dynamic range: 109.74 - 80000 pg/ml with a sensitivity of 40.88 pg/mL.
- Design your own immunoassay: we also offer the conjugation-ready antibody pair.
- Patent pending
View Alternative Names
Polymeric immunoglobulin receptor, PIgR, Poly-Ig receptor, Hepatocellular carcinoma-associated protein TB6, PIGR
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
Standard curve comparison between the Chemiluminescent Human Polymeric immunoglobulin receptor SimpleStep ELISA and colorimetric Human Polymeric immunoglobulin receptor SimpleStep ELISA (ab282302) in 1X Cell Extraction Buffer PTR. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
Interpolated concentrations of native Polymeric immunoglobulin receptor in human serum and plasma samples. The concentrations of Polymeric immunoglobulin receptor were measured in duplicates, interpolated from the Polymeric immunoglobulin receptor standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 1.25%, plasma (citrate) 1.25%, plasma (EDTA) 1.25% and plasma (heparin) 1.25%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Polymeric immunoglobulin receptor concentration was determined to be 613.22 ng/mL in serum, 713.68 ng/mL in plasma (citrate), 789.90 ng/mL in plasma (EDTA), and 666.13 ng/mL in plasma (heparin).
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
1 : 320 diluted Serum from ten individual healthy human female donors were measured in duplicate. Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Polymeric immunoglobulin receptor concentration was determined to be 962.86 ng/mL with a range of 231.17 – 2,272.98 ng/mL.
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
Standard curve comparison between the Chemiluminescent Human Polymeric immunoglobulin receptor SimpleStep ELISA and colorimetric Human Polymeric immunoglobulin receptor SimpleStep ELISA (ab282302) in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
Interpolated concentrations of native Polymeric immunoglobulin receptor in human stomach tissue extract based on a 500 µg/mL extract load. The concentrations of Polymeric immunoglobulin receptor were measured in duplicate and interpolated from the Polymeric immunoglobulin receptor standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Polymeric immunoglobulin receptor concentration was determined to be 11.18 ng/mL in stomach tissue extract.
- sELISA
Lab
Sandwich ELISA - Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (AB325725)
SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
Reactivity data
Product details
Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (ab325725) is a rapid single-wash sandwich 55-min ELISA to measure Human Polymeric immunoglobulin receptor (PIGR) in Serum, Citrate Plasma, EDTA Plasma, Heparin Plasma, Cell Culture Supernatant, Tissue Extract with a sensitivity of 40.88 pg/mL.
How the assay works
Human Polymeric immunoglobulin receptor (PIGR) ELISA Kit, Chemiluminescent (ab325725) SimpleStep Ignite™ ELISA employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time. By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colorimetric ELISAs.
Assay Specificity
Our SimpleStep Ignite™ ELISA kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Human Polymeric immunoglobulin receptor (PIGR) (ab325725) protocol summary
1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature
2. Wash
3. Add ChemiHRP development solution - incubate for 2 min
4. Read the results on a plate reader capable of luminescence detection
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation:
- Anti-PIGR antibody [EPR23314-46] - BSA and Aside free (Capture) ab281273
- Anti-PIGR antibody [EPR23314-243] - BSA and Aside free (Detector) ab281123
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com