Human Protein Z ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Human Protein Z ELISA Kit is a single-wash 90-min Simplestep used to quantify Human Protein Z with a sensitivity of 7 pg/mL. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Different formats for different needs: 10x96 plates for bulk orders and 384-well plate for higher throughput
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
Vitamin K-dependent protein Z, PROZ
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Interpolated concentration of native Protein Z was measured in duplicate at different sample concentrations. Undiluted samples are as follows : Hep G2 cell culture supernatant 25% and milk 1 : 25. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Wash Buffer PT.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Serum of ten individual healthy human male donors was measured in duplicate. Interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). The mean Protein Z concentration was determined to be 5,437 ng/mL with a range of 3,862 – 10,048 ng/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Interpolated concentration of native Protein Z was measured in duplicate at different sample concentrations. Undiluted samples are as follows : serum 1 : 5,000, plasma (citrate) 1 : 2,500, plasma (EDTA) 1 : 2,500, and plasma (heparin) 1 : 5,000. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Wash Buffer PT.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Interpolated concentration of native Protein Z was measured in duplicate at different sample concentrations in 96-well vs. 384-well plates. Undiluted samples are 1 : 5,000 human serum. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Wash Buffer PT.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Serum of ten individual healthy human female donors was measured in duplicate. Interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). The mean Protein Z concentration was determined to be 3,666 ng/mL with a range of 1,195 – 7,833 ng/mL.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Interpolated concentration of native Protein Z was measured in duplicate at different sample concentrations. Undiluted samples are as follows : urine 25% and saliva 50%. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in 1X Wash Buffer PT.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Example of human Protein Z standard curve in 1X Wash Buffer PT. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Human Protein Z ELISA Kit (AB322365)
Example of human Protein Z standard curve in 1X Wash Buffer PT in 96-well vs. 384-well plate. Background-subtracted data values (mean +/- SD) are graphed.
Reactivity data
Product details
Human Protein Z SimpleStep ELISA® kit is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of Protein Z protein in Serum, Cit Plasma, EDTA Plasma, Hep Plasma, Cell culture supernatant, Urine, Saliva, Milk. Quantitate Human Protein Z with 7 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details.
Our SimpleStep ELISA® technology provides several benefits:
-Single-wash protocol reduces assay time to 90 minutes or less
-High sensitivity, specificity and reproducibility from superior antibodies
-Fully validated in biological samples
-96-wells plate breakable into 12 x 8 wells strips, available in 10-pack (10 x 96-well plates)
-Also available in a fully validated 384-well format.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com