Human Tau ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(1 Publication)
Human Tau ELISA Kit is a single-wash 90-min Simplestep used to quantify Human Tau with a sensitivity of 16 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Validated on a number of sample types including cerebrospinal fluid (CSF)
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
MAPTL, MTBT1, TAU, MAPT, Microtubule-associated protein tau, Neurofibrillary tangle protein, Paired helical filament-tau, PHF-tau
- ELISA
Supplier Data
ELISA - Human Tau ELISA Kit (AB273617)
- sELISA
Supplier Data
Sandwich ELISA - Human Tau ELISA Kit (AB273617)
Example of human Tau standard curve in Sample Diluent NS.
The Tau standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Unknown
Sandwich ELISA - Human Tau ELISA Kit (AB273617)
Interpolated concentrations of native Tau in human SH-SY5Y cell treated for 4 hours based on 80 μg/mL extract loads and human brain tissue based on a 3.5 µg/mL extract load.
The concentrations of Tau were measured in duplicate and interpolated from the Tau standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Tau concentration was determined to be 2,500 pg/mL in SH-SY5Y mock treated extract, 2,233 pg/mL in SH-SY5Y staurosporine treated extract and 1,849 pg/mL in human brain extract. Staurosporine treatment induces Tau cleavage. As expected, there is minimum difference in Tau concentration between the staurosporine treated and mock-treated SH-SY5Y cell extract, as this kit does not differentiate between the full-length and cleaved form of Tau protein. The cleaved Tau fragment can be specifically measured using ab269557, Cleaved Tau ELISA Kit (Human Asp738/Mouse Asp713).
- sELISA
Supplier Data
Sandwich ELISA - Human Tau ELISA Kit (AB273617)
Human Tau standard curve comparison.
Standard Curve comparison between the original Human Tau SimpleStep ELISA kit (ab210972) and current Human Tau SimpleStep ELISA kit (ab273617).
Reactivity data
You may be interested in:
Why is this recommended?
We recommend this product because it’s often used in the same experiment or related research.
We advise that you always check the datasheet to ensure it fits your experiments, or contact ourtechnical teamfor help.
Product details
Human Tau ELISA Kit ab273617 is a rapid single-wash 90-min ELISA kit to measure Human Tau in cerebral spinal fluid (CSF) cell culture extracts, tissue extracts, cell culture media, serum and plasma. This SimpleStep ELISA® sensitivity is 16 pg/mL.
How the assay works
Human Tau SimpleStep ELISA® employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details.
Assay Specificity
This kit recognizes both native and recombinant human Tau protein in serum, plasma (EDTA and heparin), cell culture supernatant, cerebrospinal fluid, cell and tissue extract samples only. Urine, milk, saliva samples have not been tested with this kit. This kit is incompatible with plasma (citrate) samples.
The kit is 100% reactive with human recombinant Tau-A isoform and 61% reactive with human recombinant Tau-F isoform.
Recombinant human UCHL-1 and alpha synuclein were prepared at 7 ng/mL and assayed for cross reactivity. No cross-reactivity was observed.
Recombinant human UCHL-1 and alpha synuclein were prepared at 50 ng/mL and 2 ng/mL and tested for interference with 2 ng/mL of recombinant human Tau. No interference with was observed.
Human Tau ELISA Kit ab273617 protocol summary:
1. Mix: add samples/standards to the wells together with the capture and detector antibody cocktail. Incubate for 1 hr at room temperature
2. Wash
3. Add TMB development solution - incubate for 10 min
4. Add stop solution
5. Read the results on a plate reader at 450nm
How other researchers are using Human Tau ELISA kit ab237617
Human Tau ELISA kit ab237617 has been used in the study of microglial surveillance in neurodegenerative diseases (1).
Reference:
(1)Dayuan Wang et al. 2022, PMID:36873190
Design your own immunoassay
We offer the antibody pair used in this kit in a BSA and Azide-free format, ready for conjugation
- Human/Mouse Tau Antibody Pair - BSA and Azide free ab253413
- Anti-Tau antibody [EPR22524-211] - BSA and Azide free (Capture) ab259552
- Anti-Tau antibody [EPR22521-17] - BSA and Azide free (Detector) ab259658
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Publications (1)
Recent publications for all applications. Explore the full list and refine your search
Acta pharmaceutica Sinica. B 13:834-851 PubMed36873190
2023
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Associated Products
Alternative Version
Assay Kits
AB253350
Human GSDMD Antibody Pair - BSA and Azide free
matched-antibody-pair-kits
human-gsdmd-antibody-pair-bsa-and-azide-free-ab253350
0
(0 reviews)
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com