Rat Erythropoietin ELISA Kit (EPO)
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(1 Publication)
Rat Erythropoietin ELISA Kit (EPO) is a single-wash 90-min Simplestep used to quantify Rat Erythropoietin (EPO) with a sensitivity of 2.8 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
Erythropoietin, Epo
- ELISA
Supplier Data
ELISA - Rat Erythropoietin ELISA Kit (EPO) (AB274398)
- sELISA
Supplier Data
Sandwich ELISA - Rat Erythropoietin ELISA Kit (EPO) (AB274398)
Example of rat Erythropoietin standard curve in Sample Diluent NS.
The Erythropoietin standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Rat Erythropoietin ELISA Kit (EPO) (AB274398)
Interpolated concentrations of native Erythropoietin in Sprague Dawley (SD) rat serum and plasma samples.
The concentrations of Erythropoietin were measured in duplicates, interpolated from the Erythropoietin standard curves and corrected for sample dilution. Undiluted samples are as follows : serum 100%, plasma (citrate) 100%, plasma (EDTA) 100% and plasma (heparin) 100%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Erythropoietin concentration was determined to be 135 pg/mL in neat serum, 98 pg/mL in neat plasma (citrate) , 45 pg/mL in neat plasma (EDTA) and 73 pg/mL in neat plasma (heparin).
- sELISA
Supplier Data
Sandwich ELISA - Rat Erythropoietin ELISA Kit (EPO) (AB274398)
Interpolated concentrations of native Erythropoietin in Wistar and Fischer rat serum samples.
The concentrations of Erythropoietin were measured in duplicates, interpolated from the Erythropoietin standard curves and corrected for sample dilution. Undiluted samples are as follows : Wistar serum 100% and Fischer serum 100%. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Erythropoietin concentration was determined to be 108 pg/mL in neat Wistar rat serum and 64 pg/mL in neat Fischer rat serum.
Reactivity data
Product details
Rat Erythropoietin ELISA Kit (EPO) ab274398 is a rapid single-wash 90-min Sandwich ELISA to measure Rat Erythropoietin (EPO)in cell culture media, citrate plasma, EDTA plasma, heparin plasma, serum. This SimpleStep sensitivity is 2.8 pg/mL.
How the assay works
Rat Erythropoietin (EPO)SimpleStep ELISA®employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details.
Assay Specificity
Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.
Please refer to our protocol booklet for more details.
Rat Erythropoietin ELISA Kit (EPO) ab274398 protocol summary
1. Mix: add samples/standards to the wells together with the capture and detector antibody cocktail. Incubate 1 hr at room temperature
2. Wash
3. Add TMB development solution - incubate for 10 min
4. Add Stop solution
5. Read the results on a plate reader at 450 nm
Erythropoietin is the principal hormone involved in the regulation of erythrocyte proliferation and differentiation and the maintenance of a physiological level of circulating erythrocyte mass. Erythropoietin binds to EPOR leading to EPOR dimerization and JAK2 activation thereby activating specific downstream effectors, including STAT1 and STAT3. Erythropoietin is a secreted protein produced by kidney or liver of adult mammals and by liver of fetal or neonatal mammals. Human erythropoietin is used for the treatment of anemia. Variations affecting the human EPO gene are associated with microvascular complications of diabetes 2. Rat Erythropoietin has 94% amino acids sequence identity to mouse Erythropoietin, and 83% identity to the human Erythropoietin.
The standard is affinity purified.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Supplementary information
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
Erythropoietin regulates blood oxygen levels by stimulating erythrocyte production. It is not part of a larger complex but interacts directly with the erythropoietin receptor activating intracellular pathways necessary for erythroid progenitor cell survival and proliferation. Eyrthropoietin production increases in response to low oxygen levels in tissues ensuring adequate oxygen delivery throughout the body by increasing red blood cell count.
Pathways
Erythropoietin predominantly influences the JAK-STAT signaling pathway. Upon binding to its receptor on erythroid progenitors it activates this pathway leading to gene expression changes that promote survival and proliferation of these cells. This pathway is also involved in various immune responses and cell growth processes. Erythropoietin signaling has a regulatory relationship with other growth factors like thrombopoietin which is another hematopoietic hormone.
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Publications (1)
Recent publications for all applications. Explore the full list and refine your search
Frontiers in pharmacology 13:876573 PubMed35517793
2022
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com