Rat IL-33 ELISA Kit
- Recombinant
- SimpleStep
- What is this?
Be the first to review this product! Submit a review
|
(2 Publications)
Rat IL-33 ELISA Kit is a single-wash 90-min Simplestep used to quantify Rat IL-33 with a sensitivity of 6 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.
- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Design your own immunoassay: we also offer the conjugation-ready antibody pair
View Alternative Names
Interleukin-33, IL-33, Il33
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Comparison of IL-33 in unstimulated and LPS stimulated lung and spleen tissue supernatants.
Lung tissue was cultured for 6 days in the presence or absence (mock) of 5 μg/mL LPS. Spleen tissue was cultured for 18 hours in the presence or absence (mock) of 1 μg/mL LPS. The concentrations of IL-33 were measured in three different dilutions of the supernatant samples in duplicates and interpolated from the IL-33 standard curve. The interpolated values are plotted (mean +/- SD, n=3). The mean IL-33 concentration was determined to be 965.8 pg/mL in LPS stimulated lung tissue culture supernatant, 940.4 in unstimulated lung tissue culture supernatant, 1,463 pg/mL in LPS stimulated spleen tissue culture supernatant, 1,165 pg/mL in unstimulated spleen tissue culture supernatant, and undetectable in RPMI1640 media containing 10% FBS (not shown).
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Rat Il-33 Standard Curve Comparison.
Standard Curve comparison between Rat IL-33 SimpleStep ELISA kit and traditional ELISA kit from leading competitor. SimpleStep ELISA kit shows comparable sensitivity.
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Example of rat IL-33 standard curve in Sample Diluent NS.
Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Example of rat IL-33 standard curve in Sample Diluent 50BP.
Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Example of rat IL-33 standard curve in 1X Cell Extraction Buffer PTR.
Background-subtracted data values (mean +/- SD) are graphed.
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Interpolated concentrations of native IL-33 in rat lung tissue culture supernatant samples and rat spleen tissue supernatant samples.
Interpolated concentrations of native IL-33 in stimulated (LPS) and unstimulated (mock) 6 days rat lung tissue culture supernatant samples and stimulated and unstimulated 18 hours rat spleen tissue supernatant samples. The concentrations of IL-33 were measured in duplicates, interpolated from the IL-33 standard curves and corrected for sample dilution. Undiluted samples are as follows : lung (LPS) neat, lung (mock) neat, spleen (LPS) neat, and spleen (mock) neat. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-33 concentration was determined to be 931.1 pg/mL in LPS stimulated lung tissue supernatant, 940.4 pg/mL in unstimulated rat lung tissue supernatant, 1,503 pg/mL in LPS stimulated spleen tissue supernatant, and 1,185 pg/mL in unstimulated spleen tissue supernatant.
- sELISA
Supplier Data
Sandwich ELISA - Rat IL-33 ELISA Kit (AB236714)
Interpolated concentrations of native IL-33 in rat kidney tissue extract based on a 500 μg/mL extract load.
The concentrations of IL-33 were measured in duplicate and interpolated from the IL-33 standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean IL-33 concentration was determined to be 464.4 pg/mL in kidney tissue extract.
Reactivity data
Product details
Rat IL-33 ELISA Kit (ab236714) is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of IL-33 protein in cit plasma, hep plasma, serum, tissue extracts, and cell culture supernatant. It uses our proprietary SimpleStep ELISA® technology. Quantitate Rat IL-33 with 6 pg/ml sensitivity.
SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:
- Single-wash protocol reduces assay time to 90 minutes or less
- High sensitivity, specificity and reproducibility from superior antibodies
- Fully validated in biological samples
- 96-wells plate breakable into 12 x 8 wells strips
A 384-well SimpleStep ELISA® microplate (ab203359) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.
REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.
Precision
Recovery
What's included?
Properties and storage information
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
- Download websiteProtocolBooklet|en
Target data
Publications (2)
Recent publications for all applications. Explore the full list and refine your search
Frontiers in pharmacology 15:1345645 PubMed38476328
2024
Applications
Unspecified application
Species
Unspecified reactive species
American journal of physiology. Heart and circulatory physiology 326:H1006-H1016 PubMed38363211
2024
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com