Human CXCL2 Antibody Pair - BSA and Azide free is a kit containing recombinant capture and detector antibodies in a carrier-free formulation for the measurement of Human CXCL2.
Application | Reactivity | Dilution info | Notes |
---|---|---|---|
Application sELISA | Reactivity Reacts | Dilution info - | Notes - |
Select an associated product type
Produced by activated monocytes and neutrophils and expressed at sites of inflammation. Hematoregulatory chemokine, which, in vitro, suppresses hematopoietic progenitor cell proliferation. GRO-beta(5-73) shows a highly enhanced hematopoietic activity.
GRO2, GROB, MIP2A, SCYB2, CXCL2, C-X-C motif chemokine 2, Growth-regulated protein beta, Macrophage inflammatory protein 2-alpha, Gro-beta, MIP2-alpha
Human CXCL2 Antibody Pair - BSA and Azide free is a kit containing recombinant capture and detector antibodies in a carrier-free formulation for the measurement of Human CXCL2.
The Antibody Pair can be used to quantify Human CXCL2. BSA and Azide free antibody pairs include unconjugated capture and detector antibodies suitable for sandwich ELISAs. The antibodies are provided at an approximate concentration of 1 mg/ml as measured by the protein A280 method. The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Both capture and detector antibodies are rabbit monoclonal antibodies delivering consistent, specific, and sensitive results.
For additional information on the performance of the antibody pair, see the equivalent SimpleStep ELISA® Kit (Human MIP2 ELISA Kit (CXCL2) ab184862), which uses the same antibodies. However, due to differences in their formulation, this antibody pair cannot be used with the consumables provided with our SimpleStep ELISA Kits. Please note that the range provided for the pairs is only an estimation based on the performance of the related product using the same antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody pair in your assay.
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with <1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
The pair can be used in variety of assays and platforms including but not limited to:
Our antibody pairs are supplied in a carrier-free format that is conjugation-ready:
We can label antibodies for you: get in touch today to discuss how we can help accelerate your assay development with custom conjugation services.
Pairs are screened in biological samples, including plasma and serum, to ensure specificity in complex samples.
Please note:
The recommended antibody orientation is based on internal optimization in sandwich ELISA. Antibody orientation is assay dependent and needs to be optimized for each assay type.
The range provided for this antibody pair is based on initial sandwich ELISA validation data using recombinant protein. Performance and range of the antibody pair will depend on the specific characteristics of your assay, including standard protein selection.
We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibodies in other assays.
Antibody properties:
Capture antibody: recombinant rabbit monoclonal (unconjugated) – 100 µg
Detector antibody: recombinant rabbit monoclonal (unconjugated) - 100 µg
Concentration: ~1 mg/ml
Storage buffer: 100% PBS
Form: Liquid
Isotype: IgG
Recombinant monoclonal antibodies offer several advantages including:
- High batch-to-batch consistency and reproducibility
- Improved sensitivity and specificity
- Long-term security of supply
- Animal-free production
Meso Scale Discovery and MSD are registered trademarks of Meso Scale Diagnostics, LLC.
AlphaLISA, AlphaScreen, and DELFIA are registered trademarks of PerkinElmer, Inc.
Simoa is a registered trademark of Quanterix, Inc.
SMC is a registered trademark of Merck KGaA, Darmstadt, Germany.
The CXCL2 protein also known as macrophage inflammatory protein 2 (MIP-2) or KC in the mouse model functions as a chemokine. It weighs approximately 7.8 kDa and is part of the CXC chemokine family. CXCL2 is mainly expressed in macrophages neutrophils and certain epithelial cells. It plays an important role in mediating the migration of these cells to sites of inflammation or injury.
CXCL2 attracts and activates neutrophils as part of the innate immune response. It acts independently not as part of a larger complex to provoke a chemotactic response guiding neutrophils to areas of tissue injury. CXCL2 also promotes the release of other cytokines and enzymes that contribute to inflammation. Its activity is mediated through its interaction with receptors like CXCR2 on target cell surfaces.
CXCL2 is involved in inflammatory signaling and leukocyte migration. It holds importance in the chemokine signaling pathway which regulates leukocyte trafficking. CXCL2 interacts with proteins like CXCR2 influencing the inflammation process by activating downstream kinases and other signal transduction molecules such as mitogen-activated protein kinases (MAPKs).
CXCL2 is connected to inflammatory conditions and diseases like sepsis and inflammatory bowel disease (IBD). Elevated levels of CXCL2 can enhance the inflammatory response which is linked to the progression of these conditions. The protein is also associated with tumor necrosis factor-alpha (TNF-alpha) which amplifies inflammation and tissue damage during disease processes.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Representative Human MIP2 standard curve using sandwich ELISA method.
Representative standard curve from corresponding SimpleStep ELISA® Kit (Human MIP2 ELISA Kit (CXCL2) ab184862), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com