Human/Monkey MIP-1 alpha/CCL3 Antibody Pair - BSA and Azide free is a kit containing recombinant capture and detector antibodies in a carrier-free formulation for the measurement of Human/Monkey MIP-1 alpha/CCL3.
Application | Reactivity | Dilution info | Notes |
---|---|---|---|
Application sELISA | Reactivity Reacts | Dilution info - | Notes - |
Select an associated product type
Monokine with inflammatory and chemokinetic properties. Binds to CCR1, CCR4 and CCR5. One of the major HIV-suppressive factors produced by CD8+ T-cells. Recombinant MIP-1-alpha induces a dose-dependent inhibition of different strains of HIV-1, HIV-2, and simian immunodeficiency virus (SIV).
G0S19-1, MIP1A, SCYA3, CCL3, C-C motif chemokine 3, G0/G1 switch regulatory protein 19-1, Macrophage inflammatory protein 1-alpha, PAT 464.1, SIS-beta, Small-inducible cytokine A3, Tonsillar lymphocyte LD78 alpha protein, MIP-1-alpha
Human/Monkey MIP-1 alpha/CCL3 Antibody Pair - BSA and Azide free is a kit containing recombinant capture and detector antibodies in a carrier-free formulation for the measurement of Human/Monkey MIP-1 alpha/CCL3.
The Antibody Pair can be used to quantify Human MIP1a. BSA and Azide free antibody pairs include unconjugated capture and detector antibodies suitable for sandwich ELISAs. The antibodies are provided at an approximate concentration of 1 mg/ml as measured by the protein A280 method. The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Both capture and detector antibodies are rabbit monoclonal antibodies delivering consistent, specific, and sensitive results.
For additional information on the performance of the antibody pair, see the equivalent SimpleStep ELISA® Kit (Human MIP-1 alpha/CCL3 ELISA Kit ab214569), which uses the same antibodies. However, due to differences in their formulation, this antibody pair cannot be used with the consumables provided with our SimpleStep ELISA Kits. Please note that the range provided for the pairs is only an estimation based on the performance of the related product using the same antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody pair in your assay.
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with <1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
The pair can be used in variety of assays and platforms including but not limited to:
Our antibody pairs are supplied in a carrier-free format that is conjugation-ready:
We can label antibodies for you: get in touch today to discuss how we can help accelerate your assay development with custom conjugation services.
Pairs are screened in biological samples, including plasma and serum, to ensure specificity in complex samples.
Please note:
The recommended antibody orientation is based on internal optimization in sandwich ELISA. Antibody orientation is assay dependent and needs to be optimized for each assay type.
The range provided for this antibody pair is based on initial sandwich ELISA validation data using recombinant protein. Performance and range of the antibody pair will depend on the specific characteristics of your assay, including standard protein selection.
We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibodies in other assays.
Antibody properties:
Capture antibody: recombinant rabbit monoclonal (unconjugated) – 100 µg
Detector antibody: recombinant rabbit monoclonal (unconjugated) - 100 µg
Concentration: ~1 mg/ml
Storage buffer: 100% PBS
Form: Liquid
Isotype: IgG
Recombinant monoclonal antibodies offer several advantages including:
- High batch-to-batch consistency and reproducibility
- Improved sensitivity and specificity
- Long-term security of supply
- Animal-free production
Meso Scale Discovery and MSD are registered trademarks of Meso Scale Diagnostics, LLC.
AlphaLISA, AlphaScreen, and DELFIA are registered trademarks of PerkinElmer, Inc.
Simoa is a registered trademark of Quanterix, Inc.
SMC is a registered trademark of Merck KGaA, Darmstadt, Germany.
MIP-1 alpha also known as CCL3 is a chemokine that plays a critical role in the immune system. With a molecular weight of around 8 kDa it is primarily expressed in activated T-cells macrophages and fibroblasts. MIP-1 alpha acts as a signaling protein that binds to receptors on target cells directing the movement of immune cells. Researchers commonly refer to it using various alternative names such as MIP-1a and CCL3-alpha rat and it is frequently measured using assays like MIP-1 alpha ELISA for experimental analyses.
Proteins including MIP-1 alpha participate in the recruitment and activation of diverse immune cells aiding the inflammatory response. Through interaction with receptors like CCR1 and CCR5 MIP-1 alpha mobilizes cells like natural killer cells and monocytes. This chemokine does not generally form part of a larger protein complex but interacts directly with membrane receptors to exert its function in immune cell chemotaxis.
MIP-1 alpha operates in the context of both the inflammatory response and the chemokine signaling pathways. Its involvement in these pathways helps mediate the trafficking of leukocytes. Notably MIP-1 alpha interacts with proteins such as CCR1 and CCR5 to transmit signals that instigate immune responses. These proteins are integral to its role in modulating immunity providing targets for research into controlling inflammatory processes.
MIP-1 alpha closely relates to conditions such as rheumatoid arthritis and HIV infection. In rheumatoid arthritis its overexpression can lead to excessive inflammation and joint destruction. Meanwhile in HIV infection MIP-1 alpha interacts with CCR5 a co-receptor necessary for the virus entry into cells. This dual relationship elucidates its potential as a therapeutic target in managing both inflammatory diseases and viral entry mechanisms.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Representative standard curve from corresponding SimpleStep ELISA® Kit (Human MIP-1 alpha/CCL3 ELISA Kit ab214569), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
Representative standard curve from corresponding SimpleStep ELISA® Kit (Human MIP-1 alpha/CCL3 ELISA Kit ab214569), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com