Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266]
- BOND RX™ Validated
- RabMAb
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal Cardiac Troponin T antibody - conjugated to Alexa Fluor® 488. Suitable for Flow Cyt (Intra), IHC-P and reacts with Mouse, Rat, Human samples.
View Alternative Names
TnTc, Cardiac muscle troponin T, cTnT, TNNT2
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Immunohistochemical analysis of paraffin-embedded Human skeletal muscle tissue labeling Cardiac Troponin T with ab314676 at 1/100 (5.0 µg/ml). Negative control : no staining on human skeletal muscle. The section was incubated with ab314676 for 60 mins at room temperature (shown in green). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Immunohistochemical analysis of paraffin-embedded Human cardiac muscle tissue labeling Cardiac Troponin T with ab314676 at 1/100 (5.0 µg/ml). Cytoplasmic staining on human cardiac myocytes. The section was incubated with ab314676 for 60 mins at room temperature (shown in green). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Immunohistochemical analysis of paraffin-embedded Rat cardiac muscle tissue labeling Cardiac Troponin T with ab314676 at 1/100 (5.0 µg/ml). Cytoplasmic staining on rat cardiac myocytes. The section was incubated with ab314676 for 60 mins at room temperature (shown in green). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Immunohistochemical analysis of paraffin-embedded Mouse cardiac muscle tissue labeling Cardiac Troponin T with ab314676 at 1/100 (5.0 µg/ml). Cytoplasmic staining on mouse cardiac myocytes. The section was incubated with ab314676 for 60 mins at room temperature (shown in green). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins.
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized HL-1 (mouse atrial muscle cell) cells labelling Cardiac Troponin T with ab314676 at 1/500 dilution (0.1 µg)/(Red) compared with a Rabbit IgG monoclonal [EPR25A] - Isotype Control (Alexa Fluor® 488) (ab199091) (Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266] (AB314676)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized H9c2(2-1) (rat cardiomyoblast) cells labelling Cardiac Troponin T with ab314676 at 1/500 dilution (0.1 µg)/(Red) compared with a Rabbit IgG monoclonal [EPR25A] - Isotype Control (Alexa Fluor® 488) (ab199091) (Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
Related conjugates and formulations (3)
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Cardiac Troponin T antibody [EPR20266]
-
660 APC
APC Anti-Cardiac Troponin T antibody [EPR20266]
-
578 PE
PE Anti-Cardiac Troponin T antibody [EPR20266]
Reactivity data
Product details
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Alexa Fluor® is a registered trademark of Molecular Probes, Inc, a Thermo Fisher Scientific Company. The Alexa Fluor® dye included in this product is provided under an intellectual property license from Life Technologies Corporation. As this product contains the Alexa Fluor® dye, the purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). As this product contains the Alexa Fluor® dye the sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: in manufacturing; (ii) to provide a service, information, or data in return for payment (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are sold for use in research. For information on purchasing a license to this product for purposes other than research, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com