Anti-CD31 [EPR17259] Alexa Fluor® 647 conjugated antibody (ab305210) rabbit monoclonal antibody that is used to detect CD31 in IHC-P, mIHC. Suitable for Human, Mouse, Rat samples.
- Validated for multiplex IHC on the Leica BOND® MAX using Opal reagents
-Using biophysical QC, antibody identity is confirmed at a molecular level for unrivalled batch-batch consistency
pH: 7.4
Preservative: 0.02% Sodium azide
Constituents: 68% PBS, 30% Glycerol (glycerin, glycerine), 1% BSA
mIHC | IHC-P | |
---|---|---|
Human | Tested | Tested |
Mouse | Expected | Tested |
Rat | Expected | Tested |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info 1/100 | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Mouse, Rat | Dilution info Use at an assay dependent concentration. | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info 1/100 | Notes Perform heat-mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol. |
Species Mouse | Dilution info 1/100 | Notes Perform heat-mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol. |
Species Rat | Dilution info 1/100 | Notes Perform heat-mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol. |
Select an associated product type
Cell adhesion molecule which is required for leukocyte transendothelial migration (TEM) under most inflammatory conditions (PubMed:17580308, PubMed:19342684). Tyr-690 plays a critical role in TEM and is required for efficient trafficking of PECAM1 to and from the lateral border recycling compartment (LBRC) and is also essential for the LBRC membrane to be targeted around migrating leukocytes (PubMed:19342684). Trans-homophilic interaction may play a role in endothelial cell-cell adhesion via cell junctions (PubMed:27958302). Heterophilic interaction with CD177 plays a role in transendothelial migration of neutrophils (PubMed:17580308). Homophilic ligation of PECAM1 prevents macrophage-mediated phagocytosis of neighboring viable leukocytes by transmitting a detachment signal (PubMed:12110892). Promotes macrophage-mediated phagocytosis of apoptotic leukocytes by tethering them to the phagocytic cells; PECAM1-mediated detachment signal appears to be disabled in apoptotic leukocytes (PubMed:12110892). Modulates bradykinin receptor BDKRB2 activation (PubMed:18672896). Regulates bradykinin- and hyperosmotic shock-induced ERK1/2 activation in endothelial cells (PubMed:18672896). Induces susceptibility to atherosclerosis (By similarity). Isoform Delta15. Does not protect against apoptosis.
CD31, Platelet endothelial cell adhesion molecule, PECAM-1, EndoCAM, GPIIA', PECA1, PECAM1
Anti-CD31 [EPR17259] Alexa Fluor® 647 conjugated antibody (ab305210) rabbit monoclonal antibody that is used to detect CD31 in IHC-P, mIHC. Suitable for Human, Mouse, Rat samples.
- Validated for multiplex IHC on the Leica BOND® MAX using Opal reagents
-Using biophysical QC, antibody identity is confirmed at a molecular level for unrivalled batch-batch consistency
pH: 7.4
Preservative: 0.02% Sodium azide
Constituents: 68% PBS, 30% Glycerol (glycerin, glycerine), 1% BSA
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
For more information, read more on recombinant antibodies.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Alexa Fluor® is a registered trademark of Molecular Probes, Inc, a Thermo Fisher Scientific Company. The Alexa Fluor® dye included in this product is provided under an intellectual property license from Life Technologies Corporation. As this product contains the Alexa Fluor® dye, the purchase of this product conveys to the buyer the non-transferable right to use the purchased product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). As this product contains the Alexa Fluor® dye the sale of this product is expressly conditioned on the buyer not using the product or its components, or any materials made using the product or its components, in any activity to generate revenue, which may include, but is not limited to use of the product or its components: in manufacturing; (ii) to provide a service, information, or data in return for payment (iii) for therapeutic, diagnostic or prophylactic purposes; or (iv) for resale, regardless of whether they are sold for use in research. For information on purchasing a license to this product for purposes other than research, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.
We have tested this species and application combination and it works. It is covered by our product promise.
We have not tested this specific species and application combination in-house, but expect it will work. It is covered by our product promise.
This species and application combination has not been tested, but we predict it will work based on strong homology. However, this combination is not covered by our product promise.
We do not recommend this combination. It is not covered by our product promise.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Immunofluorescence analysis of human rectum adenocarcinoma labelled with ab305210. Image was acquired using Cell DIVE Multiplexed Imaging Solution (Leica Microsystems).
Formalin fixed paraffin embedded (FFPE) sections were incubated with ab305210 at 1/100 dilution, for 1h at room temperature. Nuclear DNA was labelled with DAPI (Red). Deparaffinization, antigen retrieval, biomarker labeling and imaging was performed following Cell DIVE recommended standard protocol. Cell DIVE automatically processed the image to perform autofluorescence removal, distortion correction, blank glass subtraction, flat-field correction, and stitching.
Immunohistochemical analysis of paraffin-embedded Rat lung tissue labeling CD31 with ab305210 at 1/100 (5.0 ug/ml). Positive staining on rat lung. The section was incubated with ab305210 for 60 mins at room temperature (shown in red). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument.Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins. Negative control: PBS instead of the primary antibody.
Immunohistochemical analysis of paraffin-embedded Mouse lung tissue labeling CD31 with ab305210 at 1/100 (5.0 ug/ml). Positive staining on endothelial cells of mouse lung. The section was incubated with ab305210 for 60 mins at room temperature (shown in red). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument.Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins. Negative control: PBS instead of the primary antibody.
Immunohistochemical analysis of paraffin-embedded Human lung tissue labeling CD31 with ab305210 at 1/100 (5.0 ug/ml). Positive staining on endothelial cells of human lung. The section was incubated with ab305210 for 60 mins at room temperature (shown in red). Nuclear DNA was labeled with DAPI (shown in blue). The section was then mounted using Fluoromount®.The immunostaining was performed on a Leica Biosystems BOND RX instrument. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 40 mins. Negative control: PBS instead of the primary antibody.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com