Rabbit Recombinant Monoclonal Angiotensinogen antibody. Carrier free. Suitable for sELISA and reacts with Human samples.
Constituents: 100% PBS
sELISA | |
---|---|
Human | Expected |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info Use at an assay dependent concentration. | Notes - |
Essential component of the renin-angiotensin system (RAS), a potent regulator of blood pressure, body fluid and electrolyte homeostasis. Angiotensin-2. Acts directly on vascular smooth muscle as a potent vasoconstrictor, affects cardiac contractility and heart rate through its action on the sympathetic nervous system, and alters renal sodium and water absorption through its ability to stimulate the zona glomerulosa cells of the adrenal cortex to synthesize and secrete aldosterone (PubMed:10619573, PubMed:17138938). Acts by binding to angiotensin receptors AGTR1 and AGTR2 (PubMed:1567413). Also binds the DEAR/FBXW7-AS1 receptor (By similarity). Angiotensin-3. Stimulates aldosterone release. Angiotensin 1-7. Is a ligand for the G-protein coupled receptor MAS1 (By similarity). Has vasodilator and antidiuretic effects. Has an antithrombotic effect that involves MAS1-mediated release of nitric oxide from platelets (By similarity).
SERPINA8, AGT, Angiotensinogen, Serpin A8
Rabbit Recombinant Monoclonal Angiotensinogen antibody. Carrier free. Suitable for sELISA and reacts with Human samples.
Constituents: 100% PBS
ab276023 is a BSA and Azide Free antibody supplied in an unconjugated format and it is suitable for sandwich ELISAs to quantify Human AGT. The recommended pair for sandwich ELISA is:
Capture: ab276023, Human AGT Capture Antibody (unconjugated)
Detector: Anti-Angiotensinogen antibody [EPR24118-74] - BSA and Azide free (Detector) ab276024, Human AGT Detector Antibody (unconjugated)
The reference range value is 0.156 - 20 ng/ml.
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
This product is a recombinant monoclonal antibody, which offers several advantages including:
For more information, read more on recombinant antibodies.
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. The carrier-free buffer and high concentration allow for increased conjugation efficiency.
This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Please note that the range provided for this antibody is only an estimation based on the performance of the product using the recommended antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody in your assay.
Angiotensinogen also known as AGT is a precursor to angiotensin peptides and plays a mechanical role in the renin-angiotensin system. It is a glycoprotein with a mass of approximately 60 kDa and is mainly produced in the liver. This protein circulates in the bloodstream where it waits for renin to cleave it. Angiotensinogen's presence is significant in various tissues but primarily it functions within the plasma after hepatic secretion.
Angiotensinogen is critical in the regulation of blood pressure and fluid balance. It serves as the substrate for renin an enzyme that initiates a cascade leading to the production of angiotensin I which further converts into active forms like angiotensin II. Angiotensinogen does not operate as part of a larger protein complex but interacts closely with enzymes and other substrates to mediate its effects on the cardiovascular system.
Angiotensinogen is an essential component of the renin-angiotensin-aldosterone system (RAAS) which helps regulate blood pressure and electrolyte balance. The pathway involves the conversion of angiotensinogen to angiotensin I by renin followed by the conversion to angiotensin II by angiotensin-converting enzyme (ACE). This system also has connections with proteins such as aldosterone which is involved in sodium and water retention influencing cardiovascular health.
Angiotensinogen links to hypertension and cardiovascular diseases. The protein's interaction with renin and ACE results in the formation of angiotensin II a potent vasoconstrictor that increases blood pressure. Elevated levels of angiotensinogen are often observed in individuals with high 117/85 blood pressure indicating a risk for chronic conditions. Managing angiotensinogen levels through RAAS modulation is a therapeutic strategy for controlling these disorders.
We have tested this species and application combination and it works. It is covered by our product promise.
We have not tested this specific species and application combination in-house, but expect it will work. It is covered by our product promise.
This species and application combination has not been tested, but we predict it will work based on strong homology. However, this combination is not covered by our product promise.
We do not recommend this combination. It is not covered by our product promise.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Example of Human AGT standard curve. Background-subtracted data values (mean +/- SD) are graphed.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com