Anti-APOBEC3G/A3G antibody [EPR25404-59]
- BOND RX™ Validated
- 20ul selling size
- RabMAb
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal APOBEC3G/A3G antibody. Suitable for IP, IHC-P, WB and reacts with Human, Transfected cell lysate - Human samples.
View Alternative Names
MDS019, APOBEC3G, DNA dC->dU-editing enzyme APOBEC-3G, APOBEC-related cytidine deaminase, APOBEC-related protein 9, CEM-15, Deoxycytidine deaminase, APOBEC-related protein, ARCD, ARP-9, CEM15, A3G
- IHC
Supplier Data
Immunohistochemistry - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Immunohistochemical analysis of paraffin-embedded human breast cancer tissue labeling APOBEC3G/A3G with ab302926 at 1/2000 (0.255 ug/ml) followed by ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Positive staining on immune cells in human breast cancer. The section was incubated with ab302926 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC
Supplier Data
Immunohistochemistry - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Immunohistochemical analysis of paraffin-embedded wild-type H9 cell pellet labeling APOBEC3G/A3G with ab302926 at 1/2000 (0.255 ug/ml) followed by ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Positive staining on wild-type H9 cell pellet (Panel A); No staining on wild-type Jurkat cell pellet (Panel B); No staining on wild-type 293T cell pellet (Panel C). The section was incubated with ab302926 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC
Supplier Data
Immunohistochemistry - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Immunohistochemical analysis of paraffin-embedded human tonsil tissue labeling APOBEC3G/A3G with ab302926 at 1/2000 (0.255 ug/ml) followed by ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Positive staining on immune cells in human tonsil. The section was incubated with ab302926 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is ready to use LeicaDS9800 (Bond® Polymer Refine Detection). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IP
Supplier Data
Immunoprecipitation - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
APOBEC3G/A3G was immunoprecipitated from 0.35 mg H9 (human lymphoma T lymphocyte) whole cell lysate 20 ug with ab302926 at 1/30 dilution (2ug in 0.35mg lysates). Western blot was performed on the immunoprecipitate using ab302926 at 1/1000 dilution. VeriBlot for IP secondary antibody(HRP)(ab131366) was used at 1/5000 dilution. Lane 1 : H9 whole cell lysate 20 ug Lane 2 : ab302926 IP in H9 whole cell lysate Lane 3 : Rabbit monoclonal IgG (ab172730) instead of ab302926 in H9 whole cell lysate Blocking and dilution buffer and concentration : 5% NFDM/TBST. Exposure time : 15 seconds.
All lanes:
Immunoprecipitation - Anti-APOBEC3G/A3G antibody [EPR25404-59] (ab302926) at 1/1000 dilution
Lane 1:
H9 (human lymphoma T lymphocyte), whole cell lysate 20 μg
Lane 2:
H9, whole cell lysate
Secondary
All lanes:
Immunoprecipitation - VeriBlot for IP Detection Reagent (HRP) (<a href='/en-us/products/reagents/veriblot-for-ip-detection-reagent-hrp-ab131366'>ab131366</a>) at 1/5000 dilution
Observed band size: 42 kDa
false
Exposure time: 15s
- WB
Supplier Data
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Blocking and diluting buffer and concentration : 5% NFDM/TBST Exposure time : 180 seconds
All lanes:
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (ab302926) at 1/1000 dilution
Lane 1:
Human tonsil tissue lysate 20 μg
Lane 2:
Human heart tissue lysate 20 μg
Secondary
All lanes:
Goat Anti-Rabbit IgG (HRP) with minimal cross-reactivity with human IgG at 1/2000 dilution
Observed band size: 42 kDa
false
Exposure time: 180s
- WB
Supplier Data
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Blocking and diluting buffer and concentration : 5% NFDM/TBST This antibody does not cross-react with human APOBEC3A or APOBEC3B Exposure time : 180 seconds
All lanes:
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (ab302926) at 1/1000 dilution
Lane 1:
293T transfected with human APOBEC3G expression vector containi a myc-His-tag®, whole cell lysate, 20 μg
Lane 2:
293T transfected with human APOBEC3A expression vector containi a myc-His-tag®, whole cell lysate, 20 μg
Lane 3:
293T transfected with human APOBEC3B expression vector containi a myc-His-tag®, whole cell lysate, 20 μg
Secondary
All lanes:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/100000 dilution
Observed band size: 42 kDa
false
Exposure time: 180s
- WB
Supplier Data
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (AB302926)
Blocking and diluting buffer and concentration : 5% NFDM/TBST Negative control : Jurkat (PMID : 14527406) Exposure time : 180 seconds
All lanes:
Western blot - Anti-APOBEC3G/A3G antibody [EPR25404-59] (ab302926) at 1/1000 dilution
Lane 1:
H9 (human lymphoma T lymphocyte), whole cell lysate 20 μg
Lane 2:
Jurkat (human T cell leukemia T lymphocyte), whole cell lysate 20 μg
Secondary
All lanes:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/20000 dilution
Observed band size: 42 kDa
false
Exposure time: 180s
Related conjugates and formulations (1)
-
Anti-APOBEC3G/A3G antibody [EPR25404-59] - BSA and Azide free
Reactivity data
Product details
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Supplementary information
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
APOBEC3G acts as a host defense mechanism against retroviral infections particularly HIV-1. It incorporates into budding virions where it exerts its antiviral effect. A3G functions within the APOBEC protein family complex that participates in innate immunity. This antiviral activity helps to inhibit viral replication by inducing lethal mutations in the viral genome.
Pathways
APOBEC3G is vital in the HIV-1 life cycle disruption pathway. It interacts with other cellular factors such as the viral protein Vif which counters APOBEC3G’s activity by targeting it for proteasomal degradation. The protein is also involved in the regulation of gene expression pathways linked to innate immune responses.
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com