Anti-beta V Tubulin antibody [AA17] - BSA and Azide free
- Recombinant
- BOND RX™ Validated
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Mouse Recombinant Monoclonal TBB6 antibody. Carrier free. Suitable for IHC-P, WB and reacts with Human samples.
View Alternative Names
Tubulin beta-6 chain, Tubulin beta class V
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human cardiac muscle tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Negative control : no staining on human cardiac muscle.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human gastric cancer tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human gastric cancer.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human ovarian cancer tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human ovarian cancer.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human lung cancer tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human lung cancer.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human colon cancer tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human colon cancer.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human tonsil tissue labeling beta V Tubulin with ab322871 at 1/2000 dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human tonsil.
The section was incubated with ab322871 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- WB
Supplier Data
Western blot - Anti-beta V Tubulin antibody [AA17] - BSA and Azide free (AB324805)
This data was developed using ab322871, the same antibody clone in a different buffer formulation.
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
Low expression : HT-29, Jurkat
In Western blot, Anti-GAPDH antibody [EPR16891] - Loading Control (ab181602) staining at 1/200000 dilution.
All lanes:
Western blot - Anti-beta V Tubulin antibody [AA17] (<a href='/en-us/products/primary-antibodies/beta-v-tubulin-antibody-aa17-ab322871'>ab322871</a>) at 1/1000 dilution
Lane 1:
HeLa (human cervical adenocarcinoma epithelial cell) whole cell lysate at 20 µg
Lane 2:
NCI-H929 (human Bone B lymphocyte) whole cell lysate at 20 µg
Lane 3:
DU 145 (human prostate carcinoma epithelial cell) whole cell lysate at 20 µg
Lane 4:
HT-29 (human colorectal adenocarcinoma epithelial cell) whole cell lysate at 20 µg
Lane 5:
Jurkat (human T cell leukemia T lymphocyte from peripheral blood) whole cell lysate at 20 µg
Secondary
All lanes:
Peroxidase-Conjugated Goat anti-Mouse IgG (H+L) at 1/10000 dilution
Observed band size: 50 kDa
false
Exposure time: 59s
Reactivity data
Product details
ab324805 is the carrier-free version of ab322871.
Want a custom formulation?
This antibody clone is manufactured by Abcam. If you require a custom buffer formulation or conjugation for your experiments, please contact orders@abcam.com
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com