Rabbit Recombinant Monoclonal BST2/Tetherin antibody. Suitable for IHC-P, IP, Flow Cyt, ICC/IF and reacts with Mouse samples. Cited in 1 publication.
pH: 7.2 - 7.4
Preservative: 0.01% Sodium azide
Constituents: PBS, 40% Glycerol (glycerin, glycerine), 0.05% BSA
IHC-P | IP | Flow Cyt | WB | ICC/IF | |
---|---|---|---|---|---|
Human | Not recommended | Not recommended | Not recommended | Not recommended | Not recommended |
Mouse | Tested | Tested | Tested | Not recommended | Tested |
Rat | Not recommended | Not recommended | Not recommended | Not recommended | Not recommended |
Species | Dilution info | Notes |
---|---|---|
Species Mouse | Dilution info 1/2000 | Notes Perform heat-mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol. |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info - | Notes Perform heat-mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol. |
Species Rat | Dilution info - | Notes Perform heat-mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol. |
Species | Dilution info | Notes |
---|---|---|
Species Mouse | Dilution info 1/30 | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Human, Rat | Dilution info - | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Mouse | Dilution info 1/500 | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Human, Rat | Dilution info - | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Mouse, Rat, Human | Dilution info - | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Mouse | Dilution info 1/100 | Notes - |
Species | Dilution info | Notes |
---|---|---|
Species Human, Rat | Dilution info - | Notes - |
Select an associated product type
IFN-induced antiviral host restriction factor which efficiently blocks the release of diverse mammalian enveloped viruses by directly tethering nascent virions to the membranes of infected cells. Acts as a direct physical tether, holding virions to the cell membrane and linking virions to each other. The tethered virions can be internalized by endocytosis and subsequently degraded or they can remain on the cell surface. In either case, their spread as cell-free virions is restricted. Its target viruses belong to diverse families, including retroviridae: human immunodeficiency virus type 1 (HIV-1), mouse mammary tumor virus (MMTV) and murine leukemia virus (MLV), filoviridae: ebola virus (EBOV), arenaviridae: lassa virus (LASV), and rhabdoviridae: vesicular stomatitis virus (VSV). Can inhibit cell surface proteolytic activity of MMP14 causing decreased activation of MMP15 which results in inhibition of cell growth and migration. Can stimulate signaling by LILRA4/ILT7 and consequently provide negative feedback to the production of IFN by plasmacytoid dendritic cells in response to viral infection. Plays a role in the organization of the subapical actin cytoskeleton in polarized epithelial cells.
CD317, Bone marrow stromal antigen 2, BST-2, HM1.24 antigen, Bst2
Rabbit Recombinant Monoclonal BST2/Tetherin antibody. Suitable for IHC-P, IP, Flow Cyt, ICC/IF and reacts with Mouse samples. Cited in 1 publication.
pH: 7.2 - 7.4
Preservative: 0.01% Sodium azide
Constituents: PBS, 40% Glycerol (glycerin, glycerine), 0.05% BSA
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
This product is a recombinant monoclonal antibody, which offers several advantages including:
For more information, read more on recombinant antibodies.
We have tested this species and application combination and it works. It is covered by our product promise.
We have not tested this specific species and application combination in-house, but expect it will work. It is covered by our product promise.
This species and application combination has not been tested, but we predict it will work based on strong homology. However, this combination is not covered by our product promise.
We do not recommend this combination. It is not covered by our product promise.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
Flow cytometric analysis of Mouse splenocyte cells labelling BST2/Tetherin with ab246508 at 1/500 dilution (Right) compared with a Rabbit monoclonal IgG (Rabbit IgG, monoclonal [EPR25A] - Isotype Control ab172730) isotype control (Left).A Goat anti rabbit IgG (Alexa Fluor® 488, Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) ab150077) at 1/2000 dilution was used as the secondary antibody.
Cells were stained with rabbit IgG (Left) or ab246508 (Right). Then stained with anti-CD45R conjugated to Alexa Fluor® 647.
Gated on viable cells.
Immunohistochemical analysis of paraffin-embedded Mouse spleen tissue labeling BST2/Tetherin with ab246508 at 1/2000 dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (Rabbit specific IHC polymer detection kit HRP/DAB ab209101). Positive staining on mouse spleen (PMID: 19903902).The section was incubated with ab246508 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (Rabbit specific IHC polymer detection kit HRP/DAB ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
BST2/Tetherin was immunoprecipitated from 0.35 mg EL4 (mouse lymphoma T lymphocyte) whole cell lysate with ab246508 at 1/30 dilution (2ug in 0.35mg lysates). Western blot was performed on the immunoprecipitate using ab246508 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP)(VeriBlot for IP Detection Reagent (HRP) ab131366) was used at 1/5000 dilution.
Lane 1: EL4 (mouse lymphoma T lymphocyte), whole cell lysate 10 ug
Lane 2: ab246508 IP in EL4 whole cell lysate
Lane 3: Rabbit monoclonal IgG (Rabbit IgG, monoclonal [EPR25A] - Isotype Control ab172730) instead of ab246508 in EL4 whole cell lysate.
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 15 seconds
BST2 is type II transmembrane glycoprotein with a molecular mass of 28-40 KD, which is consistent to the literature(PMID: 22520941; PMID: 19737401).
All lanes: Immunoprecipitation - Anti-BST2/Tetherin antibody [EPR23597-202] (ab246508)
Predicted band size: 20 kDa
Observed band size: 28-40 kDa
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% Triton X-100 permeabilized Mouse splenocyte cells labelling BST2/Tetherin with ab246508 at 1/100 dilution, followed by Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). Confocal image showing cytoplamic staining in mouse splenocyte Alexa Fluor® 594 Anti-alpha Tubulin antibody [DM1A] - Microtubule Marker ab195889 Anti-alpha Tubulin antibody (Alexa Fluor® 594) was used to counterstain tubulin at 1/200 dilution (Red). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control: Secondary antibody is Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution.
BST2/Tetherin was immunoprecipitated from 0.35 mg Mouse spleen tissue lysate 10ug with ab246508 at 1/30 dilution (2ug in 0.35mg lysates). Western blot was performed on the immunoprecipitate using ab246508 at 1/1000 dilution. VeriBlot for IP Detection Reagent (HRP)(VeriBlot for IP Detection Reagent (HRP) ab131366) was used at 1/5000 dilution. Lane 1: Mouse spleen tissue lysate 10ug
Lane 2: ab246508 IP in Mouse spleentissue lysate
Lane 3: Rabbit monoclonal IgG (Rabbit IgG, monoclonal [EPR25A] - Isotype Control ab172730) instead of ab246508 in mouse spleen tissue lysate
Blocking and dilution buffer and concentration: 5% NFDM/TBST.
Exposure time: 15 seconds
BST2 is type II transmembrane glycoprotein with a molecular mass of 28-40 KD, which is consistent to the literature(PMID: 22520941; PMID: 19737401).
All lanes: Immunoprecipitation - Anti-BST2/Tetherin antibody [EPR23597-202] (ab246508)
Predicted band size: 20 kDa
Observed band size: 28-40 kDa
Immunofluorescent analysis of 100% methanol-fixed EL.4 cells labelling BST2/Tetherin with ab246508 at 1/100 dilution, followed by Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). Confocal image showing cytoplasmic staining in EL.4 cell line. 100% methanol fixation is recommended. Alexa Fluor® 594 Anti-alpha Tubulin antibody [DM1A] - Microtubule Marker ab195889 Anti-alpha Tubulin antibody (Alexa Fluor® 594) was used to counterstain tubulin at 1/200 dilution (Red). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control: Secondary antibody is Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution.
Immunohistochemical analysis of paraffin-embedded Mouse skeletal muscle tissue labeling BST2/Tetherin with ab246508 at 1/2000 dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (Rabbit specific IHC polymer detection kit HRP/DAB ab209101). Negative control: No staining on mouse skeletal muscle (PMID: 19903902). The section was incubated with ab246508 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (Rabbit specific IHC polymer detection kit HRP/DAB ab209101).
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com