Anti-CD4 antibody [RM1136]
- BOND RX™ Validated
- Recombinant
- RabMAb
- Lab Essentials
- 20ul selling size
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Multiclonal CD4 antibody. Suitable for Flow Cyt, ICC/IF, IHC-P and reacts with Human, Mouse samples.
View Alternative Names
CD4, T-cell surface glycoprotein CD4, T-cell surface antigen T4/Leu-3
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Anti-CD4 antibody [RM1136] (AB316866)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% Tween-20 permeabilized Human PBMC (human primary peripheral blood mononuclear cell) cells labelling CD4 with ab316866 at 1/500 (1.066 ug/ml) dilution, followed by ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed antibody at 1/1000 2 ug/ml dilution (Green).
Confocal image showing membranous staining in subsets of human PBMCs (shown in green). The counterstain was observed in magenta. Nuclear DNA was labeled with DAPI (shown in blue). Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8).
Anti-human CD3 mouse monoclonal antibody (Alexa Fluor® 647) was used to counterstain tubulin at 1/200 2.5 dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control : Secondary antibody is ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 2 ug/ml dilution.
- Flow Cyt
Supplier Data
Flow Cytometry - Anti-CD4 antibody [RM1136] (AB316866)
Flow cytometric analysis of human PBMC (human peripheral blood mononuclear cell) cells labelling CD4 with ab316866 at 1/50 dilution (1 ug)/Right compared with a Rabbit monoclonal IgG (ab172730) / Left isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
Goat Anti-Rabbit IgG (Alexa Fluor® 488, ab150081) at 1/5000 dilution was used as the secondary antibody.
human PBMC are co-stained with CD3 conjugated Alexa Fluor®647.
Gated on viable cell.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD4 antibody [RM1136] (AB316866)
Immunohistochemical analysis of paraffin-embedded Human tonsil tissue labeling CD4 with ab316866 at 1/4000 (0.133 ug/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human tonsil. The section was incubated with ab316866 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD4 antibody [RM1136] (AB316866)
Immunohistochemical analysis of paraffin-embedded Human Hodgkin lymphoma tissue labeling CD4 with ab316866 at 1/4000 (0.133 ug/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human Hodgkin lymphoma. The section was incubated with ab316866 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- Flow Cyt
Supplier Data
Flow Cytometry - Anti-CD4 antibody [RM1136] (AB316866)
Flow cytometric analysis of human PBMC (human peripheral blood mononuclear cell) cells labelling CD4 with ab316866 at 1/50 dilution (1 ug)/Right compared with a Rabbit monoclonal IgG (ab172730) / Left isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
Goat Anti-Rabbit IgG (Alexa Fluor® 488, ab150081) at 1/5000 dilution was used as the secondary antibody.
human PBMC are co-stained with CD8a conjugated Pacific Blue (450/50BP).
Gated on viable cell.
- Flow Cyt
Supplier Data
Flow Cytometry - Anti-CD4 antibody [RM1136] (AB316866)
Flow cytometric analysis of mouse PBMC (mouse peripheral blood mononuclear cell) cells labelling CD4 with ab316866 at 1/50 dilution (1 ug)/Right compared with a Rabbit monoclonal IgG (ab172730) / Left isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
Goat Anti-Rabbit IgG (Alexa Fluor® 488, ab150081) at 1/5000 dilution was used as the secondary antibody.
mouse PBMC are co-stained with CD8a conjugated BV421 (440/50BP).
Gated on viable cell.
- Flow Cyt
Supplier Data
Flow Cytometry - Anti-CD4 antibody [RM1136] (AB316866)
Flow cytometric analysis of mouse PBMC (mouse peripheral blood mononuclear cell) cells labelling CD4 with ab316866 at 1/50 dilution (1 ug)/Right compared with a Rabbit monoclonal IgG (ab172730) / Left isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue).
Goat Anti-Rabbit IgG (Alexa Fluor® 488, ab150081) at 1/5000 dilution was used as the secondary antibody.
mouse PBMC are co-stained with CD3 conjugated Alexa Fluor®647.
Gated on viable cell.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-CD4 antibody [RM1136] (AB316866)
Immunohistochemical analysis of paraffin-embedded Human skeletal muscle tissue labeling CD4 with ab316866 at 1/4000 (0.133 ug/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Negative control : no staining on human skeletal muscle. The section was incubated with ab316866 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
Related conjugates and formulations (18)
-
Anti-CD4 antibody [RM1136] - BSA and Azide free
-
Anti-CD4 antibody [EPR20122]
-
Anti-CD4 antibody [SP35]
-
775 Alexa Fluor® 750
Alexa Fluor® 750 Anti-CD4 antibody [SP35]
-
660 APC
APC Anti-CD4 antibody [EPR20122]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-CD4 antibody [EPR20122]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-CD4 antibody [EPR20122]
-
578 PE
PE Anti-CD4 antibody [EPR20122]
-
Anti-CD4 antibody [EPR20122] - BSA and Azide free
-
Anti-CD4 antibody [SP35] - BSA and Azide free
-
660 APC
APC Anti-CD4 antibody [SP35]
-
HRP Anti-CD4 antibody [SP35]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-CD4 antibody [SP35]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-CD4 antibody [SP35]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-CD4 antibody [SP35]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-CD4 antibody [SP35]
-
578 PE
PE Anti-CD4 antibody [SP35]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-CD4 antibody [SP35]
Reactivity data
Product details
What are recombinant multiclonals?
Recombinant multiclonals are a mixture of recombinant antibodies co-expressed from a library of heavy and light chains. They offer several advantages including:
- - The sensitivity of polyclonal antibodies by recognising multiple epitopes
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
View our range of recombinant multiclonal antibodies.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com