Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free
- BOND RX™ Validated
- Recombinant
- RabMAb
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal COL8A1 antibody. Carrier free. Suitable for Dot, IHC-P and reacts with Recombinant fragment - Human, Human samples.
View Alternative Names
C3orf7, COL8A1, Collagen alpha-1(VIII) chain, Endothelial collagen
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human lung tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on stroma of human lung. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human placenta tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Low expression tissue : no staining on human placenta. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human cerebrum tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Low expression tissue : no staining on human cerebrum. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human colon carcinoma tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on stroma of human colon carcinoma. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human cardiac muscle tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on stroma of human cardiac muscle. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human testis tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on stroma of human testis. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human lung carcinoma tissue labeling COL8A1 with ab318972 at 1/2000 (0.264 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on stroma of human lung carcinoma. The section was incubated with ab318972 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- Dot
Supplier Data
Dot Blot - Anti-COL8A1 antibody [EPR28738-178] - BSA and Azide free (AB318973)
This data was developed using ab318972, the same antibody clone in a different buffer formulation.
Dot blot analysis of COL8A1 using ab318972 at 1 : 1000 (0.527 ug/ml) followed by a Goat Anti-Rabbit IgG, (H+L), Peroxidase conjugated (ab97051) at 1 : 100,000 dilution.
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
This antibody does not cross-react with human COL8A2.
All lanes:
Dot Blot - Anti-COL8A1 antibody [EPR28738-178] (<a href='/en-us/products/primary-antibodies/col8a1-antibody-epr28738-178-ab318972'>ab318972</a>) at 1/1000 dilution
Lane 1:
His-tagged human COL8A1 fragment
Lane 2:
His-tagged human COL8A2 fragment
Secondary
All lanes:
Dot Blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/100000 dilution
false
Exposure time: 81s
Related conjugates and formulations (1)
-
Anti-COL8A1 antibody [EPR28738-178]
Reactivity data
Product details
ab318973 is the carrier-free version of ab318972.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com