Anti-Collagen I antibody [EPR7785] – Mouse IgG1 (Chimeric) – BSA and Azide Free
- BOND RX™ Validated
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Mouse Recombinant Monoclonal COL1A1 antibody. Carrier free. Suitable for ICC/IF, IHC-P and reacts with Human samples.
View Alternative Names
Collagen alpha-1(I) chain, Alpha-1 type I collagen, COL1A1
- ICC/IF
Lab
Immunocytochemistry/ Immunofluorescence - Anti-Collagen I antibody [EPR7785] – Mouse IgG1 (Chimeric) – BSA and Azide Free (AB317799)
ab317799 staining Collagen alpha-1(I) chain in U2OS-COL1A1 cells. The cells were fixed with 100% methanol (5 min), permeabilized with 0.1% PBS-Triton X-100 for 5 minutes and then blocked with 1% BSA/10% normal goat serum/0.3M glycine in 0.1%PBS-Tween for 1h. The cells were then incubated overnight at 4°C with ab317799 at 1µg/ml and ab202272, Alexa Fluor® 594 Rabbit monoclonal [EP1332Y] to alpha Tubulin - Microtubule Marker (shown in pseudocolour magenta). Cells were then incubated with ab150117, Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 dilution (shown in green). Nuclear DNA was labelled with DAPI (shown in blue).
Also suitable in cells fixed with 4% paraformaldehyde (10 min).
Image was acquired with a high-content analyser (Operetta CLS, Perkin Elmer) and a maximum intensity projection of confocal sections is shown.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Collagen I antibody [EPR7785] – Mouse IgG1 (Chimeric) – BSA and Azide Free (AB317799)
Immunofluorescence staining of Collagen alpha-1(I) chain in sections of formalin-fixed paraffin-embedded human colon*. Performed on a Leica BOND. The section was pre-treated using heat mediated antigen retrieval with sodium citrate (pH6.0) for 20 minutes. The section was then incubated at room temperature for 1 hour with ab317799 at 1/500 dilution, and then incubated for 1 hour with ab150119 Goat Anti-Mouse IgG H&L (Alexa Fluor® 647) preadsorbed at 1/1000 dilution (shown in red). Nuclear DNA was labelled with DAPI (shown in blue). The section was then mounted using Dako Fluorescence Mounting Medium®. Image was taken with a confocal microscope (Leica-Microsystems, TCS SP8). For other IHC staining systems (automated and non-automated), customers should optimize variable parameters such as antigen retrieval conditions, antibody concentrations and incubation times. *Tissue obtained from the Human Research Tissue Bank, supported by the NIHR Cambridge Biomedical Research Centre.
Related conjugates and formulations (9)
-
Anti-Collagen I antibody [EPR7785] – Mouse IgG1 (Chimeric)
-
Anti-Collagen I antibody [EPR7785]
-
Anti-Collagen I antibody [EPR7785] - BSA and Azide free
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Collagen I antibody [EPR7785]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Collagen I antibody [EPR7785]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-Collagen I antibody [EPR7785]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-Collagen I antibody [EPR7785]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-Collagen I antibody [EPR7785]
-
775 Alexa Fluor® 750
Alexa Fluor® 750 Anti-Collagen I antibody [EPR7785]
Reactivity data
Product details
ab317799 is the carrier-free version of ab317789.
This mouse monoclonal chimeric antibody has been engineered from a RabMAb parent antibody (ab138492). By necessity, some rabbit sequence is retained as part of the variable domain. When multiplexing with other rabbit-derived antibodies, using cross absorbed Fc-reactive secondary antibodies are recommended.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Supplementary information
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
Collagen type I plays a central role in maintaining the extracellular matrix and supporting cellular environments. It interacts with other matrix proteins and cells forming complexes that help in tissue development and repair. Type I collagen is especially important in bone matrix working alongside minerals like hydroxyapatite to provide rigidity and support. Anti-collagen antibodies aid in studying its biological functions and interactions which are critical to understanding tissue dynamics.
Pathways
Collagen type I interacts with multiple signaling cascades involved in tissue remodeling and repair. It is a significant player in the TGF-β pathway which regulates fibrosis and wound healing processes. In these pathways proteins such as fibronectin and integrins work in concert with collagen type I to orchestrate cellular responses to damage. Researchers often examine its role in these pathways to uncover therapeutic possibilities for disease interventions.
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com