Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free
- RabMAb
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(1 Publication)
Rabbit Recombinant Monoclonal K2C4 antibody. Carrier free. Suitable for IHC-P, ICC/IF, IP, WB, Flow Cyt (Intra) and reacts with Human samples. Cited in 1 publication.
View Alternative Names
CYK4, KRT4, Cytokeratin-4, Keratin-4, Type-II keratin Kb4, CK-4, K4
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free (AB247316)
This data was developed using ab51599, the same antibody clone in a different buffer formulation.
Immunohistochemical staining of paraffin embedded human cervical carcinoma tissue using ab51599 (1/100). Goat anti-rabbit HRP (1/2000) used for secondary staining.
Perform heat mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol.
- ICC/IF
Unknown
Immunocytochemistry/ Immunofluorescence - Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free (AB247316)
This data was developed using ab51599, the same antibody clone in a different buffer formulation.
ICC/IF image of ab51599 stained A431 cells. The cells were 100% methanol fixed (5 min) and then incubated in 1%BSA / 10% normal goat serum / 0.3M glycine in 0.1% PBS-Tween for 1h to permeabilise the cells and block non-specific protein-protein interactions. The cells were then incubated with the antibody ab51599 at 1/100 dilution overnight at +4°C. The secondary antibody (pseudo-colored green) was Alexa Fluor® 488 goat anti- rabbit (ab150081) IgG (H+L) preadsorbed, used at a 1/1000 dilution for 1h. Alexa Fluor® 594 WGA was used to label plasma membranes (pseudo-colored red) at a 1/200 dilution for 1h at room temperature. DAPI was used to stain the cell nuclei (pseudo-colored blue) at a concentration of 1.43μM for 1hour at room temperature.
- Flow Cyt (Intra)
Lab
Flow Cytometry (Intracellular) - Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free (AB247316)
This data was developed using ab51599, the same antibody clone in a different buffer formulation. Intracellular Flow Cytometry analysis of HeLa (Human cervix adenocarcinoma epithelial cell) cells labeling Cytokeratin 4 with purified ab51599 at 1/100 dilution (10 μg/mL) (Red). Cells were fixed with 4% Paraformaldehyde and permeabilised with 90% Methanol. A Goat anti rabbit IgG (Alexa Fluor® 488, ab150077) secondary antibody was used at 1/2000. Isotype control - Rabbit monoclonal IgG (Black). Unlabeled control - Cells without incubation with primary antibody and secondary antibody (Blue).
- IP
Lab
Immunoprecipitation - Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free (AB247316)
This data was developed using ab51599, the same antibody clone in a different buffer formulation.
Purified ab51599 at 1/50 dilution (2μg) immunoprecipitating Cytokeratin 4 in HaCaT whole cell lysate.
Lane 1 (input) : HaCaT (Human skin keratinocyte) whole cell lysate 10μg
Lane 2 (+) : ab51599 + HaCaT whole cell lysate.
Lane 3 (-) : Rabbit monoclonal IgG (ab172730) instead of ab51599 in HaCaT whole cell lysate.
VeriBlot for IP Detection Reagent (HRP) (ab131366) (1/1000 dilution) was used for Western blotting.
Blocking Buffer and concentration : 5% NFDM/TBST.
Diluting buffer and concentration : 5% NFDM/TBST.
Observed band size : 59 kDa
All lanes:
Immunoprecipitation - Anti-Cytokeratin 4 antibody [EP1599Y] (<a href='/en-us/products/primary-antibodies/cytokeratin-4-antibody-ep1599y-ab51599'>ab51599</a>)
Predicted band size: 57 kDa
false
- WB
Unknown
Western blot - Anti-Cytokeratin 4 antibody [EP1599Y] - BSA and Azide free (AB247316)
This data was developed using ab51599, the same antibody clone in a different buffer formulation.
All lanes:
Western blot - Anti-Cytokeratin 4 antibody [EP1599Y] (<a href='/en-us/products/primary-antibodies/cytokeratin-4-antibody-ep1599y-ab51599'>ab51599</a>) at 1/1000 dilution
All lanes:
A431 cell lysate at 10 µg
Secondary
All lanes:
Goat anti-rabbit HRP at 1/2000 dilution
Predicted band size: 57 kDa
Observed band size: 59 kDa
false
Related conjugates and formulations (10)
-
Anti-Cytokeratin 4 antibody [EP1599Y]
-
775 Alexa Fluor® 750
Alexa Fluor® 750 Anti-Cytokeratin 4 antibody [EP1599Y]
-
578 PE
PE Anti-Cytokeratin 4 antibody [EP1599Y]
-
660 APC
APC Anti-Cytokeratin 4 antibody [EP1599Y]
-
HRP Anti-Cytokeratin 4 antibody [EP1599Y]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Cytokeratin 4 antibody [EP1599Y]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Cytokeratin 4 antibody [EP1599Y]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-Cytokeratin 4 antibody [EP1599Y]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-Cytokeratin 4 antibody [EP1599Y]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-Cytokeratin 4 antibody [EP1599Y]
Reactivity data
Product details
ab247316 is the carrier-free version of ab51599.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Publications (1)
Recent publications for all applications. Explore the full list and refine your search
Journal of orthopaedic surgery and research 18:477 PubMed37393232
2023
Applications
Unspecified application
Species
Unspecified reactive species
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com