Anti-Fibronectin antibody [EP-5] - BSA and Azide free
- BOND RX™ Validated
- Recombinant
- KO Validated
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Mouse Recombinant Monoclonal Fibronectin antibody. Carrier free. Suitable for IHC-P, ICC/IF, WB and reacts with Human samples.
View Alternative Names
FN, FN1, Fibronectin, Cold-insoluble globulin, CIG
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using ab281574 the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human colon cancer tissue labeling Fibronectin with ab281574 at 1/100 (10.52 ug/ml) dilution followed by a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) . Positive staining in stromal cells of human colon cancer.The section was incubated with ab281574 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) .
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using ab281574 the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human cervical cancer tissue labeling Fibronectin with ab281574 at 1/100 (10.52 ug/ml) dilution followed by a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) . Positive staining in stromal cells of human cervical cancer.The section was incubated with ab281574 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) .
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using ab281574 the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human prostatic hyperplasia tissue labeling Fibronectin with ab281574 at 1/100 (10.52 ug/ml) dilution followed by a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) . Positive staining in stromal cells of human prostatic hyperplasia.The section was incubated with ab281574 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond® Polymer Refine Detection) .
Heat mediated antigen retrieval with Citrate buffer (pH 6.0, epitope retrieval solution 1) for 20 mins
- ICC/IF
Lab
Immunocytochemistry/ Immunofluorescence - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using ab281574 the same antibody clone in a different buffer formulation.Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% TritonX-100 permeabilized U-87 MG cells labelling Fibronectin with ab281574 at 1/50 (21.04 ug/ml) dilution, followed by ab150113 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) antibody at 1/1000 dilution (Green). Confocal image showing cytoplasmic and membranous staining in U-87 MG cell line. ab179513 Anti-beta Tubulin rabbit monoclonal antibody was used to counterstain tubulin at 1/200 dilution (Red). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control : Secondary antibody is ab150113 Goat Anti-Mouse IgG H&L (Alexa Fluor® 488) at 1/1000 dilution.
- WB
Lab
Western blot - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using 281574, the same antibody clone in a different buffer formulation.
Blocking and diluting buffer and concentration : ntercept® (TBS) Blocking Buffer diluted with an equal volume of 0.1% TBS
The expression molecular weight observed is consistent with what has been described in the literature (PMID : 28367057).
Lanes 1-3 : Merged signal (red and green). Green - ab281574 observed at 285kDa. Red - loading control ab52901(Rabbit monoclonal [EP1331Y] to beta Tubulin) observed at 50 kDa.
Lanes 1-2 : ab281574 Anti-Fibronectin antibody was shown to react with Fibronectin in HAP1 cells in Western blot. Loss of signal was observed when Fibronectin knockout sample was used. Wild-type and Fibronectin knockout samples were subjected to SDS-PAGE.
ab281574 and Anti-beta Tubulin antibody [EP1331Y] - Loading Control (ab52901) were incubated at 4℃ overnight at 1 in 1000 dilution and 1 in 20000 dilution respectively. Blots were developed with Goat anti-Rabbit IgG H&L (IRDye® 680CW) preadsorbed (ab216777) and Goat anti-Mouse IgG H&L (IRDye® 800RD) preadsorbed (ab216772) secondary antibodies at 1 in 10000 dilution for 1 hour at room temperature before imaging.
All lanes:
Western blot - Anti-Fibronectin antibody [EP-5] (<a href='/en-us/products/primary-antibodies/fibronectin-antibody-ep-5-ab281574'>ab281574</a>) at 1/500 dilution
Lane 1:
Wild type HAP1(human chronic myelogenous leukemia near-haploid cell line), whole cell lysate at 20 µg
Lane 2:
Fibronectin knockout HAP1(human chronic myelogenous leukemia near-haploid cell line), whole cell lysate at 20 µg
Lane 3:
Human plasma lysate at 20 µg
Secondary
All lanes:
Goat Anti-Mouse IgG H&L (IRDye® 800CW) (<a href='/en-us/products/secondary-antibodies/goat-mouse-igg-h-l-irdye-800cw-preadsorbed-ab216772'>ab216772</a>) and Goat Anti-Rabbit IgG H&L (IRDye® 680RD) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-irdye-680rd-preadsorbed-ab216777'>ab216777</a>) at 1/10000 dilution
Predicted band size: 262 kDa
Observed band size: 285 kDa
false
- WB
Lab
Western blot - Anti-Fibronectin antibody [EP-5] - BSA and Azide free (AB281576)
This data was developed using 281574, the same antibody clone in a different buffer formulation.
Blocking and diluting buffer and concentration : 5% NFDM/TBST
Exposure time : Lane 1 : 125 seconds
Lane 2 : 70 seconds
All lanes:
Western blot - Anti-Fibronectin antibody [EP-5] (<a href='/en-us/products/primary-antibodies/fibronectin-antibody-ep-5-ab281574'>ab281574</a>) at 1/1000 dilution
Lane 1:
Human colon lysate at 10 µg
Lane 2:
U-87 MG (human glioblastoma-astrocytoma epithelial cell), whole cell lysate at 20 µg
Secondary
All lanes:
Peroxidase-Conjugated Goat anti-Mouse IgG (H+L) at 1/10000 dilution
Predicted band size: 262 kDa
Observed band size: 285 kDa
false
Reactivity data
Product details
ab281576 is the carrier-free version of ab281574.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Want a custom formulation?
This antibody clone is manufactured by Abcam. If you require a custom buffer formulation or conjugation for your experiments, please contact orders@abcam.com
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com