Rabbit Recombinant Monoclonal Vitronectin/S-Protein antibody - conjugated to HRP. Suitable for IHC-P, WB and reacts with Human samples.
pH: 7.4
Preservative: 0.1% Proclin 300 Solution
Constituents: PBS, 30% Glycerol (glycerin, glycerine), 1% BSA
IHC-P | WB | |
---|---|---|
Human | Tested | Tested |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info 1/100 | Notes ab199507 - Rabbit monoclonal IgG (HRP), is suitable for use an as isotype control with this antibody. Perform heat-mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol. |
Species | Dilution info | Notes |
---|---|---|
Species Human | Dilution info 1/5000 | Notes - |
Select an associated product type
Vitronectin is a cell adhesion and spreading factor found in serum and tissues. Vitronectin interact with glycosaminoglycans and proteoglycans. Is recognized by certain members of the integrin family and serves as a cell-to-substrate adhesion molecule. Inhibitor of the membrane-damaging effect of the terminal cytolytic complement pathway. Somatomedin-B is a growth hormone-dependent serum factor with protease-inhibiting activity.
Vitronectin, VN, S-protein, Serum-spreading factor, V75, VTN
Rabbit Recombinant Monoclonal Vitronectin/S-Protein antibody - conjugated to HRP. Suitable for IHC-P, WB and reacts with Human samples.
pH: 7.4
Preservative: 0.1% Proclin 300 Solution
Constituents: PBS, 30% Glycerol (glycerin, glycerine), 1% BSA
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
We have tested this species and application combination and it works. It is covered by our product promise.
We have not tested this specific species and application combination in-house, but expect it will work. It is covered by our product promise.
This species and application combination has not been tested, but we predict it will work based on strong homology. However, this combination is not covered by our product promise.
We do not recommend this combination. It is not covered by our product promise.
We are dedicated to supporting your work with high quality reagents and we are here for you every step of the way should you need us.
In the unlikely event of one of our products not working as expected, you are covered by our product promise.
Full details and terms and conditions can be found here:
Terms & Conditions.
This blot was produced using a 4-12% Bis-tris gel under the MOPS buffer system. The gel was run at 200V for 50 minutes before being transferred onto a Nitrocellulose membrane at 30V for 70 minutes. The membrane was then blocked for an hour using 2% Bovine Serum Albumin before being incubated with ab199310 overnight at 4°C. Antibody binding was visualised using ECL development solution ECL Substrate Kit (High Sensitivity) ab133406.
All lanes: Western blot - HRP Anti-Vitronectin/S-Protein antibody [EP873Y] (ab199310) at 1/5000 dilution
All lanes: Human Serum Tissue Lysate at 10 µg
Developed using the ECL technique.
Performed under reducing conditions.
Predicted band size: 54 kDa
Observed band size: 74 kDa
Exposure time: 2min
IHC image of Vitronectin/S-Protein staining in a section of formalin-fixed paraffin-embedded normal human liver*, performed on a Leica BOND. The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH6, epitope retrieval solution 1) for 20mins. The section was then incubated with ab199310 at 1/100 dilution for 15 mins at room temperature. DAB was used as the chromogen. The section was then counterstained with haematoxylin and mounted with DPX. The inset negative control image is taken from an identical assay without primary antibody.
For other IHC staining systems (automated and non-automated) customers should optimize variable parameters such as antigen retrieval conditions, primary antibody concentration and antibody incubation times.
*Tissue obtained from the Human Research Tissue Bank, supported by the NIHR Cambridge Biomedical Research Centre.
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com