Rabbit Recombinant Monoclonal LAIR1 antibody. Suitable for WB, IHC-P and reacts with Recombinant fragment - Human, Human samples.
View Alternative Names
CD305, LAIR1, Leukocyte-associated immunoglobulin-like receptor 1, LAIR-1, hLAIR1
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Immunohistochemical analysis of paraffin-embedded Human colon tissue labeling LAIR1 with ab323640 at 1/100 (4.89 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on immunocytes of human colon.
The section was incubated with ab323640 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling LAIR1 with ab323640 at 1/100 (4.89 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on Kupffer cells of human liver (PMID : 31019980).
The section was incubated with ab323640 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Immunohistochemical analysis of paraffin-embedded Human lung carcinoma tissue labeling LAIR1 with ab323640 at 1/100 (4.89 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human lung carcinoma.
The section was incubated with ab323640 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Immunohistochemical analysis of paraffin-embedded Human tonsil tissue labeling LAIR1 with ab323640 at 1/100 (4.89 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human tonsil.
The section was incubated with ab323640 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- WB
Supplier Data
Western blot - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
Low expression : human skeletal muscle.
In Western blot, Anti-GAPDH antibody [EPR16891] - Loading Control (ab181602) staining at 1/200000 dilution.
All lanes:
Western blot - Anti-LAIR1 antibody [EPR24745-9] (ab323640) at 1/1000 dilution
Lane 1:
Human tonsil tissue lysate at 20 µg
Lane 2:
Human skeletal muscle tissue lysate at 20 µg
Secondary
All lanes:
Goat Anti-Rabbit IgG (HRP) with minimal cross-reactivity with human IgG at 1/2000 dilution
Observed band size: 37 kDa,36 kDa
false
Exposure time: 70s
- WB
Supplier Data
Western blot - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
Negative control : HeLa, A-172.
In Western blot, Anti-GAPDH antibody [EPR16891] - Loading Control (ab181602) staining at 1/200000 dilution.
All lanes:
Western blot - Anti-LAIR1 antibody [EPR24745-9] (ab323640) at 1/1000 dilution
Lane 1:
THP-1 (human monocytic leukemia monocyte) whole cell lysate at 20 µg
Lane 2:
CCRF-CEM (human peripheral blood t lymphoblast) whole cell lysate at 20 µg
Lane 3:
HeLa (human cervical adenocarcinoma epithelial cell) whole cell lysate at 20 µg
Lane 4:
A-172 (human brain glioblastoma cell ) whole cell lysate at 20 µg
Secondary
All lanes:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/20000 dilution
Observed band size: 37 kDa,36 kDa
false
Exposure time: 15s
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Immunohistochemical analysis of paraffin-embedded Human skeletal muscle tissue labeling LAIR1 with ab323640 at 1/100 (4.89 ug/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Low expression tissue : No staining in human skeletal muscle.
The section was incubated with ab323640 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- WB
Supplier Data
Western blot - Anti-LAIR1 antibody [EPR24745-9] (AB323640)
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
This antibody does not cross-react with recombinant human LAIR2 by western blot.
In Western blot, Anti-6X His tag® antibody [EPR20547] - ChIP Grade (ab213204) staining at 1/5000 dilution.
All lanes:
Western blot - Anti-LAIR1 antibody [EPR24745-9] (ab323640) at 1/1000 dilution
Lane 1:
His-tagged human LAIR1 fragment at 10 ng
Lane 2:
His-tagged human LAIR2 fragment at 10 ng
Observed band size: 31 kDa,23 kDa
false
Exposure time: 92s
Reactivity data
Product details
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com