Anti-LOX 1 antibody [EPR27185-134]
- RabMAb
- Recombinant
- 20ul selling size
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal LOX 1 antibody. Suitable for Flow Cyt, IHC-P, WB and reacts with Human samples.
View Alternative Names
CLEC8A, LOX1, OLR1, Oxidized low-density lipoprotein receptor 1, Ox-LDL receptor 1, C-type lectin domain family 8 member A, Lectin-like oxidized LDL receptor 1, Lectin-type oxidized LDL receptor 1, LOX-1, Lectin-like oxLDL receptor 1, hLOX-1
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded Human skeletal muscle tissue labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Low expression tissue : Weak staining on human skeletal muscle (HPA datasheet).
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded Human spleen tissue labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human spleen.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- Flow Cyt
Lab
Flow Cytometry - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Flow cytometric analysis of 786-O (human kidney epithelial cell, Left) DLD-1 (human colorectal adenocarcinoma epithelial cell, Right) cells labelling LOX 1 with ab325339 at 1/500 dilution (0.1ug) / Red compared with a Rabbit monoclonal IgG (ab172730) / Black isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody)/ Blue.
Goat anti-Rabbit IgG (Alexa Fluor® 647, ab150083) at 1/5000 dilution was used as the secondary antibody.
Gated on viable cells. Negative control : 786-O.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded (A) DLD-1 (human colorectal adenocarcinoma epithelial cell) cell pellet and (B) 786-O (human kidney epithelial cell) cell pellet labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on (A) DLD-1 cell pellet, no staining on (B) 786-O cell pellet.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded Human colon carcinoma tissue labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on immune cells in human colon carcinoma.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded Human ovarian carcinoma tissue labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on immune cells in human ovarian carcinoma.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Immunohistochemical analysis of paraffin-embedded Human placenta tissue labeling LOX 1 with ab325339 at 1/100 (5.05 µg/ml) dilution, followed by a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Positive staining on human placenta (PMID : 18599643).
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use LeicaDS9800 (Bond™ Polymer Refine Detection).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- WB
Lab
Western blot - Anti-LOX 1 antibody [EPR27185-134] (AB325339)
Blocking and diluting buffer and concentration : 5% NFDM/TBST.
Negative control : 786-O.
Low expression : THP-1.
In Western blot, Anti-GAPDH antibody [EPR16891] - Loading Control (ab181602) (1 : 200000) (36KDa).
All lanes:
Western blot - Anti-LOX 1 antibody [EPR27185-134] (ab325339) at 1/1000 dilution
Lane 1:
DLD-1 (human colorectal adenocarcinoma epithelial cell) whole cell lysate at 20 µg
Lane 2:
786-O (human kidney epithelial cell) whole cell lysate at 20 µg
Lane 3:
HCT-15 (human colon epithelial cell) whole cell lysate at 20 µg
Lane 4:
THP-1 (human monocytic leukemia monocyte) whole cell lysate at 20 µg
Secondary
All lanes:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/en-us/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/20000 dilution
Observed band size: 35-42 kDa,36 kDa
false
Exposure time: 180s
Related conjugates and formulations (1)
-
Anti-LOX 1 antibody [EPR27185-134] - BSA and Azide free
Reactivity data
Product details
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com