JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB240184

Anti-MVP antibody [EPR13227(B)] - BSA and Azide free

Be the first to review this product! Submit a review

|

(1 Publication)

Rabbit Recombinant Monoclonal MVP antibody. Carrier free. Suitable for IHC-P, WB, ICC/IF, Flow Cyt (Intra) and reacts with Human samples. Cited in 1 publication.

View Alternative Names

LRP, MVP, Major vault protein, Lung resistance-related protein

8 Images
Immunocytochemistry/ Immunofluorescence - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • ICC/IF

Lab

Immunocytochemistry/ Immunofluorescence - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Immunocytochemistry/Immunofluorescence analysis of HeLa cells labelling MVP with purified ab175239 at a dilution of 1/150. Cells were fixed with 4% paraformaldehyde and permeabilized with 0.1% Triton X-100. ab150077, an Alexa Fluor® 488-conjugated goat anti-rabbit IgG (1/1000) was used as the secondary antibody. DAPI (blue) was used as the nuclear counterstain. ab7291, a mouse anti-tubulin (1/1000) and ab150120, an Alexa Fluor® 594-conjugated goat anti-mouse IgG (1/1000) were also used.

Control 1 : primary antibody (1/150) and secondary antibody, ab150120, an Alexa Fluor® 594-conjugated goat anti-mouse IgG (1/1000).

Control 2 : ab7291 (1/1000) and secondary antibody, ab150077, an Alexa Fluor® 488-conjugated goat anti-rabbit IgG (1/1000).

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • IHC-P

Supplier Data

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of human pancreas tissue labeling MVP with unpurified ab175239 at a dilution of 1/50.

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Perform heat mediated antigen retrieval before commencing with IHC staining protocol.

Immunocytochemistry/ Immunofluorescence - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • ICC/IF

Supplier Data

Immunocytochemistry/ Immunofluorescence - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Immunocytochemistry/Immunofluorescence analysis of A549 cells labeling MVP with unpurified ab175239 at a dilution of 1/250 (red) and DAPI staining (blue).

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • IHC-P

Supplier Data

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of human colon tissue labeling MVP with unpurified ab175239 at a dilution of 1/50.

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Perform heat mediated antigen retrieval before commencing with IHC staining protocol.

Flow Cytometry (Intracellular) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • Flow Cyt (Intra)

Lab

Flow Cytometry (Intracellular) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Intracellular Flow Cytometry analysis of A549 cells labelling MVP with purified ab175239 at a dilution of 1/180 (red). Cells were fixed with 4% paraformaldehyde. A FITC-conjugated goat anti-rabbit IgG (1/500) was used as the secondary antibody. Black - Isotype control, rabbit monoclonal IgG. Blue - Unlabelled control, cells without incubation with primary and secondary antibodies.

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Flow Cytometry (Intracellular) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • Flow Cyt (Intra)

Supplier Data

Flow Cytometry (Intracellular) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Intracellular flow cytometrical analysis of permeabilized A549 cells labeling MVP with unpurified ab175239 antibody at a dilution of 1/100 (red) compared to a negative control (Rabbit IgG, green).

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • IHC-P

Lab

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of human colon tissue labelling MVP with purified ab175239 at a dilution of 1/350. Heat mediated antigen retrieval was performed using EDTA buffer pH 9. ab97051, a HRP-conjugated goat anti-rabbit IgG (H+L) was used as the secondary antibody (1/500). Negative control using PBS instead of primary antibody. Counterstained with hematoxylin.

This data was developed using the same antibody clone in a different buffer formulation containing PBS, BSA, glycerol, and sodium azide (ab175239).

Western blot - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)
  • WB

Lab

Western blot - Anti-MVP antibody [EPR13227(B)] - BSA and Azide free (AB240184)

This data was developed using the same antibody clone in a different buffer formulation (ab175239).

Lanes 1-4 : Merged signal (red and green). Green - ab175239 observed at 110 kDa. Red - loading control ab8245 observed at 37 kDa.

ab175239 Anti-MVP antibody [EPR13227(B)] was shown to specifically react with MVP in wild-type HeLa cells. Loss of signal was observed when knockout cell line ab264817 (knockout cell lysate ab257544) was used. Wild-type and MVP knockout samples were subjected to SDS-PAGE. ab175239 and Anti-GAPDH antibody [6C5] - Loading Control (ab8245) were incubated overnight at 4°C at 1 in 2000 and 1 in 20000 dilution respectively. Blots were developed with Goat anti-Rabbit IgG H&L (IRDye® 800CW) preadsorbed (ab216773) and Goat anti-Mouse IgG H&L (IRDye® 680RD) preadsorbed (ab216776) secondary antibodies at 1 in 20000 dilution for 1 hour at room temperature before imaging.

All lanes:

Western blot - Anti-MVP antibody [EPR13227(B)] (<a href='/en-us/products/primary-antibodies/mvp-antibody-epr13227b-ab175239'>ab175239</a>) at 1/2000 dilution

Lane 1:

Wild-type HeLa lysate at 20 µg

Lane 2:

MVP knockout HeLa lysate at 20 µg

Lane 2:

Western blot - Human MVP knockout HeLa cell line (<a href='/en-us/products/cell-lines/human-mvp-knockout-hela-cell-line-ab264817'>ab264817</a>)

Lane 3:

A549 lysate at 20 µg

Lane 4:

MOLT-4 lysate at 20 µg

Predicted band size: 99 kDa

Observed band size: 110 kDa

false

Key facts

Host species

Rabbit

Clonality

Monoclonal

Clone number

EPR13227(B)

Isotype

IgG

Carrier free

Yes

Reacts with

Human

Applications

Flow Cyt (Intra), WB, IHC-P, ICC/IF

applications

Immunogen

The exact immunogen used to generate this antibody is proprietary information.

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Species", "Dilution Info", "Notes"], "tabs": { "all-applications": {"fullname" : "All Applications", "shortname": "All Applications"}, "IHCP" : {"fullname" : "Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections)", "shortname":"IHC-P"}, "WB" : {"fullname" : "Western blot", "shortname":"WB"}, "ICCIF" : {"fullname" : "Immunocytochemistry/ Immunofluorescence", "shortname":"ICC/IF"}, "FlowCytIntra" : {"fullname" : "Flow Cytometry (Intracellular)", "shortname":"Flow Cyt (Intra)"} }, "product-promise": { "all": "all", "testedAndGuaranteed": "tested", "guaranteed": "expected", "predicted": "predicted", "notRecommended": "not-recommended" } }, "values": { "Human": { "IHCP-species-checked": "testedAndGuaranteed", "IHCP-species-dilution-info": "", "IHCP-species-notes": "<p></p> Perform heat-mediated antigen retrieval before commencing with IHC staining protocol.", "WB-species-checked": "testedAndGuaranteed", "WB-species-dilution-info": "", "WB-species-notes": "<p></p>", "ICCIF-species-checked": "testedAndGuaranteed", "ICCIF-species-dilution-info": "", "ICCIF-species-notes": "<p></p>", "FlowCytIntra-species-checked": "testedAndGuaranteed", "FlowCytIntra-species-dilution-info": "", "FlowCytIntra-species-notes": "<p><a href='/en-us/products/primary-antibodies/rabbit-igg-monoclonal-epr25a-isotype-control-low-endotoxin-azide-free-ab199376'>ab199376</a> - Rabbit monoclonal IgG, is suitable for use as an isotype control with this antibody.</p>" } } }

Product details

ab240184 is the carrier-free version of ab175239.

Species reactivity
Mouse, Rat: We have preliminary internal testing data to indicate this antibody may not react with these species.
Please contact us for more information.

Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.

What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:

  • - High batch-to-batch consistency and reproducibility
  • - Improved sensitivity and specificity
  • - Long-term security of supply
  • - Animal-free batch production

For more information, read more on recombinant antibodies.

Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.

Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.

Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.

Properties and storage information

Form
Liquid
Purification technique
Affinity purification Protein A
Storage buffer
pH: 7.2 - 7.4 Constituents: PBS
Shipped at conditions
Blue Ice
Appropriate short-term storage conditions
+4°C
Appropriate long-term storage conditions
+4°C
Storage information
Do Not Freeze

Product protocols

For this product, it's our understanding that no specific protocols are required. You can visit:

Target data

Required for normal vault structure. Vaults are multi-subunit structures that may act as scaffolds for proteins involved in signal transduction. Vaults may also play a role in nucleo-cytoplasmic transport. Down-regulates IFNG-mediated STAT1 signaling and subsequent activation of JAK. Down-regulates SRC activity and signaling through MAP kinases.
See full target information MVP

Publications (1)

Recent publications for all applications. Explore the full list and refine your search

Cell 187:4193-4212.e24 PubMed38942014

2024

Microglial-derived C1q integrates into neuronal ribonucleoprotein complexes and impacts protein homeostasis in the aging brain.

Applications

Unspecified application

Species

Unspecified reactive species

Nicole Scott-Hewitt,Matthew Mahoney,Youtong Huang,Nils Korte,T Yvanka de Soysa,Daniel K Wilton,Emily Knorr,Kevin Mastro,Allison Chang,Allison Zhang,David Melville,Monica Schenone,Christina Hartigan,Beth Stevens
View all publications

Product promise

We are committed to supporting your work with high-quality reagents, and we're here for you every step of the way. In the unlikely event that one of our products does not perform as expected, you're protected by our Product Promise.
For full details, please see our Terms & Conditions

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com