Anti-OSMR antibody [EPR29920-534] - BSA and Azide free
- RabMAb
- Recombinant
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal OSMR antibody. Carrier free. Suitable for ICC/IF and reacts with Transfected cell line - Human, Human samples.
View Alternative Names
OSMRB, OSMR, Oncostatin-M-specific receptor subunit beta, Interleukin-31 receptor subunit beta, IL-31 receptor subunit beta, IL-31R subunit beta, IL-31R-beta, IL-31RB
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Anti-OSMR antibody [EPR29920-534] - BSA and Azide free (AB325947)
This data was developed using ab323715, the same antibody clone in a different buffer formulation.
Immunofluorescent analysis of 100% methanol-fixed 0.1% TritonX-100 permeabilized A375 (human malignant melanoma epithelial cell) cells labelling OSMR with ab323715 at 1/100 (5.08 ug/ml) dilution followed by ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed antibody at 1/1000 2ug/ml dilution (Green).
Confocal image showing membrane and cytoplasmic staining in A375 cell line (shown in green). The counterstain was observed in magenta. Nuclear DNA was labelled with DAPI (shown in blue).
Low expression : Jurkat (PMID : 28607076).
Image was taken with a confocal microscope (Leica-Microsystems TCS SP8).
ab195889 Anti-alpha Tubulin mouse monoclonal antibody - Microtubule Marker (Alexa Fluor® 594) was used to counterstain tubulin at 1/200 2.5ug/ml dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control : Secondary antibody is ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 2ug/ml dilution.
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Anti-OSMR antibody [EPR29920-534] - BSA and Azide free (AB325947)
This data was developed using ab323715, the same antibody clone in a different buffer formulation.
Immunofluorescent analysis of 4% Paraformaldehyde-fixed 0.1% TritonX-100 permeabilized 293T (human embryonic kidney epithelial cell) cells labelling OSMR with ab323715 at 1/100 (5.08 ug/ml) dilution followed by ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed antibody at 1/1000 2ug/ml dilution (Green).
Confocal image showing cytoplasmic staining in 293T cells (shown in green) transfected with a human OSMR expression vector containing a Myc tag. The counterstain was observed in magenta. Nuclear DNA was labelled with DAPI (shown in blue). Image was taken with a confocal microscope (Leica-Microsystems TCS SP8).
ab223894 Anti-Myc tag mouse monoclonal antibody (Alexa Fluor® 594) was used to counterstain tubulin at 1/100 5ug/ml dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control : Secondary antibody is ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 2ug/ml dilution.
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - Anti-OSMR antibody [EPR29920-534] - BSA and Azide free (AB325947)
This data was developed using ab323715, the same antibody clone in a different buffer formulation.
Immunofluorescent analysis of 100% methanol-fixed 0.1% TritonX-100 permeabilized A-172 (human brain glioblastoma cell) cells labelling OSMR with ab323715 at 1/100 (5.08 ug/ml) dilution followed by ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed antibody at 1/1000 2ug/ml dilution (Green).
Confocal image showing membrane and cytoplasmic staining in A-172 cell line (shown in green). The counterstain was observed in magenta. Nuclear DNA was labelled with DAPI (shown in blue).
Low expression : JAR (PMID : 8999038).
Image was taken with a confocal microscope (Leica-Microsystems TCS SP8).
ab195889 Anti-alpha Tubulin mouse monoclonal antibody - Microtubule Marker (Alexa Fluor® 594) was used to counterstain tubulin at 1/200 2.5ug/ml dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
Secondary antibody only control : Secondary antibody is ab150081 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) preadsorbed at 1/1000 2ug/ml dilution.
Reactivity data
Product details
ab325947 is the carrier-free version of ab323715
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com