PE Anti-Cardiac Troponin T antibody [EPR20266]
- Recombinant
- RabMAb
- What is this?
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal Cardiac Troponin T antibody - conjugated to PE. Suitable for ICC/IF, Flow Cyt (Intra), IHC-P and reacts with Mouse, Rat, Human samples.
View Alternative Names
TnTc, Cardiac muscle troponin T, cTnT, TNNT2
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - PE Anti-Cardiac Troponin T antibody [EPR20266] (AB322129)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized L6 (rat skeletal muscle myoblast) cells labelling Troponin T with ab322129 at 1/500 dilution (0.1ug) (Red) compared with a Rabbit IgG monoclonal [EPR25A] - Isotype Control (Phycoerythrin) (ab209478) (Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody).
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - PE Anti-Cardiac Troponin T antibody [EPR20266] (AB322129)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% TritonX-100 permeabilized L6 (rat skeletal muscle myoblast) cells labelling Troponin T with ab322129 at 1/50 (10.0 ug/ml) dilution (Green).
Confocal image showing cytoplasmic staining in L6 cells (shown in magenta). The counterstain was observed in green. Nuclear DNA was labeled with DAPI (shown in blue). Image was taken with a confocal microscope(Leica-Microsystems, TCS SP8).
ab195887 Anti-alpha Tubulin mouse monoclonal antibody - Microtubule Marker (Alexa Fluor® 488) was used to counterstain tubulin at 1/200 2.5ug/ml dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - PE Anti-Cardiac Troponin T antibody [EPR20266] (AB322129)
Flow cytometric analysis of 4% paraformaldehyde fixed 90% methanol permeabilized HL-1 (mouse atrial muscle cell) cells labelling Troponin T with ab322129 at 1/500 dilution (0.1ug) (Red) compared with a Rabbit IgG monoclonal [EPR25A] - Isotype Control (Phycoerythrin) (ab209478) (Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody).
- ICC/IF
Supplier Data
Immunocytochemistry/ Immunofluorescence - PE Anti-Cardiac Troponin T antibody [EPR20266] (AB322129)
Immunofluorescent analysis of 4% Paraformaldehyde-fixed, 0.1% TritonX-100 permeabilized HL-1 (mouse atrial muscle cell) cells labelling Troponin T with ab322129 at 1/50 (10.0 ug/ml) dilution (Green).
Confocal image showing cytoplasmic staining in HL-1 cells (shown in magenta). The counterstain was observed in green. Nuclear DNA was labeled with DAPI (shown in blue). Image was taken with a confocal microscope(Leica-Microsystems, TCS SP8).
ab195887 Anti-alpha Tubulin mouse monoclonal antibody - Microtubule Marker (Alexa Fluor® 488) was used to counterstain tubulin at 1/200 2.5ug/ml dilution (Magenta). The Nuclear counterstain was DAPI (Blue).
Related conjugates and formulations (5)
-
Anti-Cardiac Troponin T antibody [EPR20266] - BSA and Azide free
-
Anti-Cardiac Troponin T antibody [EPR20266]
-
660 APC
APC Anti-Cardiac Troponin T antibody [EPR20266]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-Cardiac Troponin T antibody [EPR20266]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-Cardiac Troponin T antibody [EPR20266]
Reactivity data
Product details
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Properties and storage information
Form
Purification technique
Storage buffer
Shipped at conditions
Appropriate short-term storage duration
Appropriate short-term storage conditions
Appropriate long-term storage conditions
Aliquoting information
Storage information
Product protocols
- Visit the General protocols
- Visit the Troubleshooting
Target data
Product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com